SAFETY INSTRUCTIONS

3

When operating this Stapler, the operator and others in the work area should ALWAYS wear approved 
SAFETY GLASSES, with FRONT and SIDE eye protection.  Eye protection will help guard against 
fl ying nails and debris, which could cause severe eye injury.

EAR PROTECTION should be used to prevent hearing damage when there are high noise levels in 

the work area.  ALWAYS use ear plugs with a noise reduction rated at 29 db or higher at a construction 
site.

  Stapler noise ratings are at LPA-1sd=90.6, 
  LWA-1sd=99.3 and LPA-1s,1m=86.3. 
  Stapler vibration rating: m/s2=3.05.

Always DISCONNECT THE AIR SUPPLY before making any adjustments, repairing, clearing jams or when 
the Stapler is not in use. Do not use on scaffolding or ladders and disconnect Stapler from air supply when 
transporting  between installation areas.

Never attach the female end of a quick disconnect to the Stapler. This will trap air inside the Stapler and permit it 
to be discharged. Only the unrestricted male connection should be attached to the Stapler.

Stapler requires an air source that can continuously deliver 70 to 110 psi at 3-1/2 cubic feet of air per minute for 
operation.

Normal air pressure should not exceed 110 psi or damage to the Stapler and seals may occur. Excess air 
pressure can cause the Stapler to explode.

To prevent fi re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no 
oxygen or combustible gasses) to power this Stapler.

Stapler is intended for use installing wood fl ooring and is not to be used for purposes not specifi ed in the 
operations manual.

Do not use any staples other than Powernail® Powerstaples which are specifi cally designed for use in any 
Powerstapler.  Powercleats Staples are available in various lengths.  Contact your Powernail Dealer for 
Powernail Staples.

Use only Powernail replacement parts in the repair or maintenance of this Stapler. Parts or repair services are 
available from the manufacturer or from agents authorized by the manufacturer. Repairs should be carried out 
only by trained service personel in the fi eld of fastener driving tools who will observe proper safety controls while 
performing maintenance. Service personel should be qualifi ed to assess the safe working condition of fastener 
driving tools.

Always make sure Stapler is empty of nails before connecting air hose, so as to prevent any accidental 
discharge from occurring.  ONLY CONNECT AIR TO AN UNLOADED Stapler.

Do not depress the trigger when loading.  If the fasteners are jammed, disconnect the tool from the air supply 
before you remove the jammed nails.

Never place any part of the body in the discharge path of the Stapler when air is connected to the 
Stapler. Never point the tool at yourself or others, even if the tool is not loaded. For safety, keep out of 
reach of children. Never leave the Stapler unattended while it is connected to an air supply.

Do not fi re into hard materials or attempt to use on hard or brittle material such as concrete, steel or tile. Before 
using this tool, carefully check that all parts are working correctly.  Do not use the tool if it is not operating 
correctly, check for causes and adjust as necessary for proper operation. When not in use, the tool should be 
cleaned, fully assembled and then stored in a dry location.  This will extend the life of the tool and reduce any 
oxidation. 

   

Содержание PowerStapler 20FS

Страница 1: ...If you are uncertain about the operation of the stapler call us directly at 1 800 323 1653 for assistance or contact the closest Powernail Dealer for help Please retain this information for future ref...

Страница 2: ...must be made no later than fifteen 15 days after the end of the warranty period POWERNAIL will perform all repair or replacements itself or through its authorized contractors POWERNAIL is not respons...

Страница 3: ...erations manual Do not use any staples other than Powernail Powerstaples which are specifically designed for use in any Powerstapler Powercleats Staples are available in various lengths Contact your P...

Страница 4: ...eumatic stapler look to the company that has been the industry s quality leader Powernail Company Inc FOOT ADJUSTMENT STAPLE LOCATION Figure 1 Loosen both adjusting knobs 76 Hold stapler on sample pie...

Страница 5: ...s of air tool oil in the air plug as shown in Figure 3 If you are using an automatic in line oiler check and add oil if necessary 3 Turn your compressor on and set the compressors pressure regulator t...

Страница 6: ...and is replaced from the top of the stapler MAINTENANCE 14 13 12 11 10 9 8 7 6 5 4 3 2 1 14a 14b 15 16 17 18 19 22 23 24 25 36 37 38 46 34 35 62 27 33 31 32 31 30 28 39 77 73 71 80 75 72 76 50 51 74...

Страница 7: ...tall silver colored safety slide 75 into the silver foot 71 2 Next install the gate 50 and gate plate 72 over the safety slide 75 3 Install the two M4 screws 78 thru the front of the silver foot 71 th...

Страница 8: ...10 9 8 7 6 5 4 3 2 1 14a 14b 15 16 17 18 19 22 23 24 25 36 37 38 46 34 35 62 27 33 31 32 31 30 28 39 77 73 71 80 75 72 76 50 51 74 78 43 52 53 43 44 45 56 55 54 1 57 58 59 60 63 64 65 66 36 61 29 79 2...

Страница 9: ...Pin n a 36 Locking Washer 09 20FS 5036 37 Spring n a 38 Trigger n a 39 Pin n a 43 Screw n a 44 Movable Magazine Unit n a 45 Stopped Block n a ITEM DESCRIPTION PART 46 Spring Washer n a 50 Gate 09 20F...

Страница 10: ...strips into place and ratchets tightly for hands free operation The base of the PowerJack 500 has mounting holes for mid floor use Simply screw nail the PowerJack 500 to your sub floor in front of yo...

Страница 11: ...f front plate 3 Inadequate air ow to tool 3 Check hose and compressor tting 4 Worn or dry O ring on piston 4 Replace O ring or lubricate 5 Cylinder cap seal leaking 5 Replace seal 6 Fasteners are jamm...

Страница 12: ...POWERNAIL COMPANY INC 1300 Rose Road Lake Zurich IL 60047 US Phone 1 800 323 1653 or 847 847 3000 www powernail com 12...

Отзывы: