background image

5

to staple down fl ooring. Before storing the Stapler, 

lubricate and cycle the Stapler in insure internal parts 

are oil protected from corrosion.

WARNING: 

Detergent oil is not recommended and may 

damage the seals. 

TO LOAD MODEL 445FS: 

Place two sticks (90 PowerStaples) into the Staple 

Channel feed slot. Pull back the spring loaded Staple 

Pusher over the staples until it contacts the last staple 

and slowly release the Staple Pusher.

TO UNLOAD MODEL 445FS:

To remove staples from the Staple Channel, pull the two 

round knobs on the Staple Pusher together. This will 

clear it from the staple path. Then turn the Stapler over 

so the staples slide out of the channel.

PARTS & SERVICE:

When ordering parts include the part number, part 

description, PowerStapler model and serial number. Be 

sure to state the quantity of the part(s) required. Contact 

your Powerstaple Dealer for the necessary parts.

WARNING:

 Never work on the Stapler if the air line is 

attached. Always disconnect the air line from the Stapler 

fi rst.

Stapler DISASSEMBLY:
TO REPLACE RUBBER BUMPER (#20 or #65):

1. Disconnect the air supply
2. Remove the four (4) cap screws holding the Adapter 

Foot, Foot and Staple Channel assembly to the main 

Body (see illustration).
3. Pull the Rubber Bumper out of the cylinder bore. 

Replace the old Bumper if it shows signs of wear or it is 

split.
4. Reverse these steps to reassemble the Stapler. Be 

sure to align the Driving Blade with the slot in the Staple 

Channel Assembly while you reassemble the Stapler. 

WARNING: 

It is not necessary to hit the Stapler hard 

to activate it.  Never hit the Stapler with excessive 

force or with the metal end of the mallet, this will 

damage the Stapler.

DO NOT USE THE METAL END OF THE MALLET 

TO STRIKE THE PLUNGER,

 use the rubber capped 

end only. 
Never use the Safety Trigger interlock to lock up 

the plunger and rack the wood with blows to the 

Stapler body. This will severely damage the safety 

mechanism and Stapler. This abuse and damage is 

not covered by the warranty.
Before each use, check all screws to be sure they are 

tight. Shock and vibration can loosen screws. Do not 

over tighten any screw.

AIR SUPPLY:

The air must be clean and dry. Dirty and/or wet air will 

damage the Stapler. 
Drywall Dust:

• Using Pneumatic PowerStaplers in drywall dust 

conditions will dramatically decrease the life of the 

Stapler.
• Drywall dust is abrasive, when cycled through 

the Stapler it will cause excessive wear.

The air source must continuously deliver 80 to 110 

psi at 3-1/2 cubic feet of air per minute to operate 

the Stapler. For operation, connect a 1/4” minimum 

internal diameter and clean air hose to the Stapler.  

Be sure the air regulator is set at 90 psi. If the staple 

is not countersunk below the surface of the wood, turn 

up the air pressure, but not over 110 psi.
Check for air supply leaks that waste air and starve 

the Stapler of air thereby reducing its performance. 

There should be no orifi ce smaller than 1/4” in the air 

path between the Regulator and the Stapler.

LUBRICATION:

You must lubricate the Stapler manually. The 

frequency of lubrication is dependent upon the duty 

cycle of the Stapler. Continuous duty requires more 

frequent oiling than intermittent duty.
At least every eight (8) hours place two to four drops 

of Air Tool Oil, supplied with your Stapler, into the 

disconnected air line male connector attached to the 

Stapler.

WARNING:

 Do not over lubricate the Stapler, excess 

oil mist or drops will be vented with spent air when 

over lubricated. Excess oil could stain the wood 

fl ooring, walls or furnishings. Dry fi re the Stapler, 

without staples, to purge excess oil, before you begin 

OPERATING INSTRUCTIONS,

 continued

Содержание 445FS

Страница 1: ...T D ENTRETIEN Read this manual before you use this PowerStapler Follow all safety warnings and instructions If you are uncertain about the operation of the stapler call us directly at 1 800 323 1653 f...

Страница 2: ...s warranty Claims must be made no later than fteen 15 days after the end of the warranty period POWERNAIL will perform all repair or replacements itself or through its authorized contractors POWERNAIL...

Страница 3: ...should only be pulled when the Stapler is in proper Position on the work surface and before the plunger is struck with the mallet Do not tie or tape down the safety trigger as the Stapler could discha...

Страница 4: ...pocket OPERATING INSTRUCTIONS 1 Loosen 2 hex screws 2 Raise or lower the FLEX to your wood sample 3 Match the Locating Ear to the nail pocket 4 Tighten 2 hex screws 5 Test wood sample with new adjustm...

Страница 5: ...HE PLUNGER use the rubber capped end only Never use the Safety Trigger interlock to lock up the plunger and rack the wood with blows to the Stapler body This will severely damage the safety mechanism...

Страница 6: ...air supply 2 Remove Rubber Plunger Cap 18 3 Unscrew remove Body Cap 2 4 Push Safety Yoke 8 aside and unscrew the three 10 32 cap screws holding the Plunger 12 to the Return Cylinder 11 5 Pull the Plun...

Страница 7: ...Place a new O Ring Gasket in the groove on top of the Return Cylinder when you reassemble the Driving Blade Assembly 2 Wipe o the O Ring Gasket seal surface and lubricate it generously with Pneumatic...

Страница 8: ...1 TU SEAL S A 5 A 11 27 09 445 29732 TRIGGER CABLE LONG 1 S A 6 28 09 445 29732 1 TRIGGER CABLE SHORT 1 S A 7 29 09 445 29733 SAFETY YOKE SPRINGS 2 S 30 09 445 29326 STAPLE PUSHER SPRING 1 S A 9 A 10...

Страница 9: ...2X 25 SET SCREW 2 S 88 09 50P 3088 ROLLER COVER LG COVER ONLY 4 S A 1 89 09 50P 3089 DOWEL 125 DIA X 38 4 S 91 09 445 29876 ROLLER ADAPTER FOOT 445 2 S 93 09 50P 3093 ROLLER SM BEARING BLOCK RIGHT SID...

Страница 10: ...10 Pneumatic Seal Part Numbers and Locations...

Страница 11: ...Model 445FS Power Roller Kits Available For use on the Model 445FS Stapler Seal Kit 1 Each Of All Seals Tune up Kit Part 09 2003058A Schematic s 19 21 22 23 24 25 26 Part 09 445FSTUKIT Schematic s 14...

Страница 12: ...te Do not leave air attached to the Nailer when moving from one install location to another Re ll the nail channel with a clip of Powercleats when empty Pull the Nail Pusher assembly to the back of th...

Страница 13: ...Replace gate 44 4 Stapler leaks air 1 Air supply fittings loose Tighten all air line fitting connections 2 Dry wall dust in Stapler Rebuild Stapler 3 Excess air pressure blew out seals Check air suppl...

Страница 14: ...31 32 3 4 FLOORING UNDERLAYMENT 3 4 31 32 33 32 FLOORING UNDERLAYMENT 3 4 1 1 8 1 2 FLOORING UNDERLAYMENT 3 4 1 UNDERLAYMENT 5 8 FLOORING 3 4 13 16 3 4 FLOORING UNDERLAYMENT 3 4 31 32 1 2 FLOORING UND...

Страница 15: ...15 POWERNAIL COMPANY INC 1300 Rose Road Lake Zurich IL 60047 US Phone 1 800 323 1653 or 847 847 3000 www powernail com...

Страница 16: ...can be used to either push or pull wood ooring strips into place and ratchets tightly for hands free operation The base of the PowerJack 500 has mounting holes for mid oor use Simply screw nail the P...

Отзывы: