background image

3

SAFETY INSTRUCTIONS

Always use approved 

SAFETY GLASSES 

and

 EAR PROTECTION

 when operating this stapler.  The 

operator and others in the work area should always wear approved 

FRONT 

and

 SIDE

 eye protection 

when operating this stapler.  Eye protection will help guard against fl ying staples and debris, which could 
cause severe eye injury.

EYE AND EAR PROTECTION

 should be used to prevent hearing damage when there are high noise 

levels in the work area.  
ALWAYS use ear plugs with a noise reduction rated at 29 db or highter at a construction site. 

Stapler noise ratings are at LPA-1sd=90.6, 
LWA-1sd=99.3 and LPA-1s,1m=86.3.  
Stapler vibration rating: m/s2=3.05.

Always 

DISCONNECT THE AIR SUPPLY

 before making any adjustments, repairing, clearing jams or when the 

stapler is not in use. Do not use on scaff olding or ladders and disconnect stapler from air supply when transporting   

between installation areas.
Never attach the female end of a quick disconnect to the stapler. This will trap air inside the Stapler and permit it to 

be discharged. Only the unrestricted male connection should be attached to the Stapler.
Stapler requires an air source that can continuously deliver 80 to 110 psi at 3-1/2 cubic feet of air per minute for 

operation.

Normal air pressure should not exceed 120 psi or damage to the Stapler and seals may occur. Excess air 

pressure can cause the Stapler to explode.
To prevent fi re or explosion, use only regulated compressed air—do not use bottled gases of any kind (no oxygen 

or combustible gasses) to power this Stapler.
Stapler is intended for use installing wood fl ooring and is not to be used for purposes not specifi ed in the 

operations manual.
The trigger is a safety device and should only be pulled when the Stapler is in proper Position on the work surface 

and before the plunger is struck with the mallet. Do not tie or tape down the safety trigger as the Stapler could 

discharge if dropped on the plunger. The Stapler will not fi  re unless the trigger is pulled before the mallet blow. Do 

not use the trigger safety as a lock up for the plunger then rack the wood using the locked up Stapler body. It will 

severely damage the Mechanism and the Stapler. Use the mallet to rack the wood strip, not the Stapler.
Do not use any nails other than Powernail Powercleats Nails which are specifi cally designed for use in any 

Powerstapler.  Powercleats Nails are available in various lengths.  Contact your Powernail Dealer for Powercleats 

Nails.
Use only Powernail replacement parts in the repair or maintenance of this stapler. Parts or repair services are 

available from the manufacturer or from agents authorised by the manufacturer. Repairs should be carried out 

only by trained service personel in the fi eld of fastener driving tools who will observe proper safety controls while 

performing maintenace. Service personel should be qualifi ed to to asses the safe working condition of fastener 

driving tools. 

Never place any part of the body in the discharge path of the Stapler when air is connected to the 

Stapler.  Always make sure Stapler is empty of cleats before connecting air hose so as to prevent any 

accidental discharge from occurring.
Never leave the Stapler unattended while it is connected to an air supply.

Whenever air is connected to the Stapler, keep body parts away from the nail discharge path.  Disconnect the air 

line before making adjustments or repairs on the Stapler.  Only connect air to an unloaded Stapler so as to prevent 

accidental discharge.

POWERNAIL COMPANY, INC.

1300 Rose Road, Lake Zurich, IL 60047 US

Phone: 1-800-323-1653 OR 847-847-3000

www.powernail.com

Содержание 445FS

Страница 1: ...T D ENTRETIEN Read this manual before you use this PowerStapler Follow all safety warnings and instructions If you are uncertain about the operation of the stapler call us directly at 1 800 323 1653 f...

Страница 2: ...s warranty Claims must be made no later than fteen 15 days after the end of the warranty period POWERNAIL will perform all repair or replacements itself or through its authorized contractors POWERNAIL...

Страница 3: ...should only be pulled when the Stapler is in proper Position on the work surface and before the plunger is struck with the mallet Do not tie or tape down the safety trigger as the Stapler could discha...

Страница 4: ...pocket OPERATING INSTRUCTIONS 1 Loosen 2 hex screws 2 Raise or lower the FLEX to your wood sample 3 Match the Locating Ear to the nail pocket 4 Tighten 2 hex screws 5 Test wood sample with new adjustm...

Страница 5: ...HE PLUNGER use the rubber capped end only Never use the Safety Trigger interlock to lock up the plunger and rack the wood with blows to the Stapler body This will severely damage the safety mechanism...

Страница 6: ...air supply 2 Remove Rubber Plunger Cap 18 3 Unscrew remove Body Cap 2 4 Push Safety Yoke 8 aside and unscrew the three 10 32 cap screws holding the Plunger 12 to the Return Cylinder 11 5 Pull the Plun...

Страница 7: ...Place a new O Ring Gasket in the groove on top of the Return Cylinder when you reassemble the Driving Blade Assembly 2 Wipe o the O Ring Gasket seal surface and lubricate it generously with Pneumatic...

Страница 8: ...1 TU SEAL S A 5 A 11 27 09 445 29732 TRIGGER CABLE LONG 1 S A 6 28 09 445 29732 1 TRIGGER CABLE SHORT 1 S A 7 29 09 445 29733 SAFETY YOKE SPRINGS 2 S 30 09 445 29326 STAPLE PUSHER SPRING 1 S A 9 A 10...

Страница 9: ...2X 25 SET SCREW 2 S 88 09 50P 3088 ROLLER COVER LG COVER ONLY 4 S A 1 89 09 50P 3089 DOWEL 125 DIA X 38 4 S 91 09 445 29876 ROLLER ADAPTER FOOT 445 2 S 93 09 50P 3093 ROLLER SM BEARING BLOCK RIGHT SID...

Страница 10: ...10 Pneumatic Seal Part Numbers and Locations...

Страница 11: ...Model 445FS Power Roller Kits Available For use on the Model 445FS Stapler Seal Kit 1 Each Of All Seals Tune up Kit Part 09 2003058A Schematic s 19 21 22 23 24 25 26 Part 09 445FSTUKIT Schematic s 14...

Страница 12: ...te Do not leave air attached to the Nailer when moving from one install location to another Re ll the nail channel with a clip of Powercleats when empty Pull the Nail Pusher assembly to the back of th...

Страница 13: ...Replace gate 44 4 Stapler leaks air 1 Air supply fittings loose Tighten all air line fitting connections 2 Dry wall dust in Stapler Rebuild Stapler 3 Excess air pressure blew out seals Check air suppl...

Страница 14: ...31 32 3 4 FLOORING UNDERLAYMENT 3 4 31 32 33 32 FLOORING UNDERLAYMENT 3 4 1 1 8 1 2 FLOORING UNDERLAYMENT 3 4 1 UNDERLAYMENT 5 8 FLOORING 3 4 13 16 3 4 FLOORING UNDERLAYMENT 3 4 31 32 1 2 FLOORING UND...

Страница 15: ...15 POWERNAIL COMPANY INC 1300 Rose Road Lake Zurich IL 60047 US Phone 1 800 323 1653 or 847 847 3000 www powernail com...

Страница 16: ...can be used to either push or pull wood ooring strips into place and ratchets tightly for hands free operation The base of the PowerJack 500 has mounting holes for mid oor use Simply screw nail the P...

Отзывы: