第 11 页 共 16 页
Mode
Parameter
Default
Rang
Comment
4 3
0
0
/
1
/
2
/
3
Special Running Mode setup
:
0
:
operator select
1
:
simple sewing mode
2
:
calculate initial angle of motor (do not uninstall strap)
3
:
calculate motor/machine head run rate mode
(synchronizer, do not uninstall strap)
4 4
0
0
—
31
Torque boost up at low speed :
0
:
no action
1~31
:
31 levels Torque boost up
4 5
1
0
/
1
Stop pin mode
:
0
:
Constant speed tackle mode (in the belt transmission,
Parking is not precision)
1
:
back pull mode
(
PMX
)
4 6
100
0 ~800
Command button to fill half-needle time
47 150
0
~800
Command button to fill a needle time
5 0
1
1~100
Stitch counting proportion set up
51 1
1~9999
Stitch counting value set up
5 2
0
0~4
Stitch counting mode selection:
0: no counting
1: Counting up according to stitch number, after reaching set value
then restart.
2: Counting down according to stitch number, after reaching set
value then restart.
3: Counting up according to stitch number, after reaching set value,
then motor should stop automatically, recounting should be restart
by S4 [152.INI] =CRS or the button A on operation panel.
4: Counting down according to stitch number, after reaching set
value, motor should stop automatically, recounting should be restart
by S4 [152.INI] =CRS or the button A on operation panel.
5 3
1
1~100
Trimming counting proportion set up
Count
Mode
5 4
1
1~9999
Trimming counting value set up