Troubleshooting PM2205 Cyclone Dust Collector
WARNING:
Some corrections may require a qualified electrician.
10.1
Electrical and motor problems (PM2205)
Symptom Possible
Cause
Correction
Motor will not start.
No incoming current.
Check connections at plug or circuit panel.
Safety key missing from switch.
Install safety key.
Motor overheated, relay tripped.
Allow machine to cool, then press reset
button and restart.
Low voltage.
Check power line for proper voltage.
Open circuit in motor or loose
connection.
Inspect all connections to switch box and
motor for loose or open connections.
Faulty start switch.
Inspect and replace switch if needed.
Faulty start capacitor.
Replace capacitor.
Faulty motor.
Inspect and replace motor if needed.
Motor will not start:
fuse blows or circuit
breaker trips.
Too many machines on shared
circuit.
Connect dust collector to dedicated circuit.
Short circuit in line cord or plug.
Inspect cord or plug for damaged
insulation and shorted wires.
Short circuit in motor or loose
connections.
Inspect all connections on motor for loose
or shorted terminals or worn insulation.
Incorrect fuse or circuit breaker in
power line.
Install correct fuse or circuit breaker at
power source.
Motor overheats.
Motor overloaded.
Reduce load on motor.
Air circulation through motor is
restricted.
Clean motor fan to restore normal air
circulation.
Motor stalls, resulting
in blown fuses or
tripped circuit.
Motor overloaded.
Reduce load on motor.
Short circuit in motor or loose
connections.
Inspect connections on motor for loose or
shorted terminals or worn insulation.
Low voltage.
Correct low voltage conditions.
Incorrect fuse or circuit breaker in
power line.
Install correct fuse or circuit breaker.
Loud noise or
vibrations coming
from machine.
Loose fasteners.
Inspect machine and tighten all fasteners.
Motor fan is hitting the cover.
Tighten fan or shim cover. Replace fan
cover if damaged.
Impeller is damaged.
Replace impeller.
Remote controller fails
to activate machine.
Stop button still engaged.
Disengage stop button.
Batteries drained.
Replace batteries.
Remote needs resetting.
Follow instructions for clearing and
resetting.
Table 4
Содержание 1792205HK
Страница 17: ...17 11 1 1 PM2205 Cyclone Dust Collector Exploded View ...
Страница 20: ...20 12 0 Electrical Connections for PM2205 Cyclone DC ...
Страница 22: ...22 This page intentionally left blank ...
Страница 23: ...23 This page intentionally left blank ...
Страница 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...