Owner’s Manual for Water Pump
7
Assembly
Call Powermate
®
Customer Service at 1-800-
445-1805 for any assembly issues or
concerns. Please have model and serial
number available.
Installing the Hoses
IMPORTANT NOTE: Verify that both hoses
are rated for water temperatures of 41° to
113°F (5° to 45° C). Hotter or colder water
can rupture the hoses.
1. Place water pump in desired operating
location.
2. See Figure 2-6. Connect the suction hose
(A) by threading the hose nut (B) onto the
pump flange (C).
Figure 2-6. Connecting the Hoses
3. Tighten the hose nut with the spanner
wrench (D).
NOTE:
Do not overtighten the hose nuts.
Overtightening the hose nuts will damage or
crack the threads.
4. Connect the discharge hose using the
same procedure.
5. See Figure 2-7. Attach the strainer (E) to
the end of the suction hose.
Figure 2-7. Attaching the Strainer
Priming the Pump
IMPORTANT NOTE: Failure to prime the
pump will cause pump damage and void
the warranty.
See Figure 2-8. Remove water priming plug
(A) and fill the pump with water. Replace water
priming plug.
Figure 2-8. Water Priming Plug
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
(000197)
CAUTION
Equipment damage. Use only hoses and couplings
designed for this pump. Incorrect hoses and couplings
can cause performance issues and permanent
equipment damage.
000852
D
A
B
C
000814
E
000797
A
Содержание PP0100363