9. Check position of dipswitch #2 to be sure it coincides with the
installation. (Left Hand or Right Hand) If this is correct and operator is
1Ø consult the factory. (1-800-243-4476).
10. If dipswitch #2 is in the correct position and the operator is 3Ø,
switch two incoming leads and repeat step #5.
WARNING:
UNDER NO CIRCUMSTANCES SHOULD THE
CONTROL STATION WIRING BE ALTERED IF THE ROTATION IS
INCORRECT. TO DO SO WILL CAUSE SOME CONTROL FUNCTIONS
TO BE INOPERATIVE, AND MAY RESULT IN PERSONAL INJURY OR
DAMAGE TO THE GATE AND/OR OPERATOR.
11.
If the operator functions properly, run the operator to the open limit
switch and turn off the power.
12.
If there is still a distance before the gate is fully open, turn off power,
move the open limit nut away from the open limit switch a few turns
and turn on the power.
13.
Press the OPEN button again to check how much further the gate
opened.
14.
Continue this procedure until the OPEN limit is set.
NOTE:
When making fine adjustments, turn the limit nut to turn at a
time; reconnect power and test run the gate.
15.
Repeat procedure for the CLOSE limit adjustment.
NOTE:
Open and Close Limit Switches are
Reversed
for
slide left to
Open Operation.
16. After the desired open and close position of the gate has been
obtained, make certain that a groove in both limit nuts are engaged
by the pressure plate.
OPEN LIMIT SWITCH
For Slide Right To Open
Operation
Pressure Plate
Limit nut
Limit nut
CLOSE LIMIT SWITCH
for slide right to open
operation
Limit Shaft