background image

PH4000Ri/E Owner’s Manual

39

9.2.  Engine will not crank with the key or remote start

To check spark:

1. 

Remove the spark plug cap and clean any dirt from 

around the spark plug.

2. 

Remove the spark plug and install the spark plug in 

the spark plug cap.

3. 

Attach the plug side electrode to your ground wire.

4. 

Quickly turn the key in the ignition to START 

position for a few cycles -- sparks should jump 

across the gap.

Ground Wire

Spark Plug Boot

Spark Plug

YES

NO

NO

NO

NO

No 

Spark

YES

YES

YES

Is there fuel in the tank?

Refuel the fuel tank.

Is the ignition switch on?

Turn the ignition switch to the “START” 

position.

Is there enough oil in the engine?

Add the recommended oil.

Is there a spark from the spark plug?

Warning!

• 

Be sure there is no spilled fuel around 

the spark plug.

• 

Spilled fuel may ignite.

If the engine still does not start, take it to 

an authorized POWERHOUSE

®

 dealer.

Replace the
spark plug.

Take the generator 

to an authorized 

POWERHOUSE

®

 dealer.

YES

NO

Does the battery have a charge?

*

Fully charge the battery.

*

  The battery must have at least 10V to power the fuel pump and the ECU before it will start by any method. If the battery has a 

charge and the generator will not start, ensure that the battery is fully charged and try to start it again before proceeding to the next 

troubleshooting step.

Содержание PH4000Ri/E

Страница 1: ...POWERHOUSE PH4000Ri E Electronic Fuel Injected Digital Inverter Generator Owner s Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING...

Страница 2: ...door and connect the quick connect cable to the battery wiring harness Refer to Connecting The Battery for more information 3 Replace the maintenance door 4 Connect an external battery charger such as...

Страница 3: ...three seconds to allow the fuel pressure to build and the throttle valve to close iv Push the start button on the remote and hold until the engine has started or for a maximum of 10 seconds Release a...

Страница 4: ...Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequ...

Страница 5: ...rranty powerhouse products com or send a fax to 1 855 242 8922 Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s manual...

Страница 6: ...plication 23 6 11 Generator Overload 24 6 12 Overspeed Protection 24 6 13 DC Application 25 6 13 1 Charging External Batteries 25 6 13 2 Powering 12V DC devices 26 6 13 3 Back charging the generator b...

Страница 7: ...des increased efficiency over carbureted fuel systems In a carbureted fuel system the fuel and air are mixed in a carburetor that relies on a mechanical choke system controlling the rate of air intake...

Страница 8: ...il tight For safety reasons it is better to shut the generator down before moving it You should also unplug all cords connected to the generator to prevent a tripping hazard and or damage to the cords...

Страница 9: ...amage and or severe personal injury or death may result Never connect this generator to an automatic transfer switch ATS Severe damage to the generator will occur Never connect this generator to an au...

Страница 10: ...wner s Manual 10 4 Component identification 4 1 PH4000Ri E Generator Control panel Gas gauge Gas cap Starter grip Engine oil access door Pneumatic tire Maintenance door Stabilizing rubber feet Telesco...

Страница 11: ...OTTANT SYSTEM FLOATING RESEAU FLOTTANT Digital display Ignition switch Fault code button 120 V circuit breakers 120 V duplex receptacle Stop button red Ground terminal 120 V locking receptacle Low oil...

Страница 12: ...enerator toward the muffler grill close to the bottom 2 On the back of this owner s manual You can also find the BCN number on the foil label on the shipping carton Please record this information belo...

Страница 13: ...es below 32 F You can use synthetic oil the first time you fill the oil well of your generator and you can use it for subsequent oil changes 1 Loosen the oil access cover screw and remove the cover 2...

Страница 14: ...operly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapor may ignite If any fuel is spilled make sure the area is dry before starting the engine Avoid repeated or prol...

Страница 15: ...to connect the battery before you begin using the generator Due to the nature of lead acid batteries it may be necessary to charge the battery before using the generator the first time or after long t...

Страница 16: ...reported by a sensor These shutdowns may occur when you are not present When the generator engine shuts off there will still be a drain on the battery due to the display the ECU and the stepper motor...

Страница 17: ...of how you start the unit If the battery charge is just high enough to run the fuel pump and the ECU the generator can be started by recoil but not by the ignition key or remote You must either charg...

Страница 18: ...using the remote function 1 Move the remote selector switch on the control panel to the ON position 2 Push the start button on the remote twice and hold while the engine cranks 2 3 times without start...

Страница 19: ...erator is 0 to 113 F 18 to 45 C Although the generator can operate at 0 F 18 C it will be necessary to use a lower viscosity engine oil such as SAE 0W 40 Synthetic oil is recommended for temperatures...

Страница 20: ...receptacle Do not connect the generator to a household circuit This could cause damage to the generator or to electrical appliances in the house Do not modify or use the generator for purposes other...

Страница 21: ...lay will not illuminate unless the generator is started It is normal for the run time indicator to have 1 2 hours on the meter from the factory for testing and quality assurance inspections The digita...

Страница 22: ...ection of this manual When the Low Oil indicator blinks repeatedly press the fault code button on the top right of the digital display The display will cycle through the fault codes in the Wattage P d...

Страница 23: ...is illuminated and returning data 3 Confirm that the appliance to be used is switched off before plugging into the control panel 4 Plug the appliance into the control panel Be sure that all appliance...

Страница 24: ...t exceed that of the generator 6 12 Overspeed Protection This generator has been designed to prevent the engine from overspeed revving Overspeed revving occurs when a generator s on board monitoring s...

Страница 25: ...cord to the positive battery terminal Do not reverse the charging cables or serious damage to the generator and or battery may occur Physical injury may also occur Do not attempt to start an automobi...

Страница 26: ...re are no special considerations for switches to be on or off for the battery to charge though if the generator is not running the remote switch should be in the OFF position The ECU and fuel pump req...

Страница 27: ...codes section of this manual for more information 6 15 Stopping the engine To stop the engine in an emergency 1 Push the STOP button on the control panel This will stop the unit with or without the i...

Страница 28: ...as started and is performing normally It is also important to follow the air conditioner manufacturer s instructions for starting and restarting for proper operation Some air conditioner manufacturers...

Страница 29: ...standards regarding the emission control system Tune up specifications are provided in the Specifications section and a description of the emission control system may be found in the appendix to this...

Страница 30: ...o compare the emission performance of different engines The lower the air index the better the engine emission performance The description of durability is helpful for the user to learn the engine emi...

Страница 31: ...ine Check Every 2 years Replace as necessary 3 Battery Clean Charge Charge monthly during long term storage Check terminals for corrosion monthly clean as needed Expected battery life is 2 years but c...

Страница 32: ...dipstick 6 Reinstall the oil access cover and tighten the screw securely Recommended oil is SAE 10W 30 or 15W 30 when ambient temperature is above 32 F 0 C SAE 0W 30 or 0W 40 is recommended if operati...

Страница 33: ...id engine wear may result 1 Loosen the cover screws and remove the maintenance door 2 Remove the cartridge retaining screws Remove the cartridge and check the element Clean or replace the element if n...

Страница 34: ...y carefully bending the side electrode 9 Install the spark plug carefully by hand to avoid cross threading 10 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wren...

Страница 35: ...ff the grill This will not cause an issue unless you drop the arrester or the clamp or screws behind the grill Taking the grill off or leaving it on is a matter of your convenience but the procedure b...

Страница 36: ...nerator while it is on or in a vehicle If you must transport the generator in an enclosed vehicle drain all fuel from the generator 8 2 Short term storage of the Generator During short term storage th...

Страница 37: ...ignition switch to the OFF position 4 Siphon the fuel from the tank 5 Change the engine oil 6 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder 7 Crank the engin...

Страница 38: ...rator and retry Is the key fob battery drained Replace the key fob battery Is the remote switch turned off Turn on the remote switch Is the battery fuse missing or burned out Is the battery dead Check...

Страница 39: ...on switch on Turn the ignition switch to the START position Is there enough oil in the engine Add the recommended oil Is there a spark from the spark plug Warning Be sure there is no spilled fuel arou...

Страница 40: ...or equipment Check for power using a meter or a known good appliance Did pressing the overload reset button cause the appliance to operate Replace the electrical appliance or equipment Take the elect...

Страница 41: ...F7RTC Starting system Remote Electric Recoil Fuel Automotive unleaded gasoline Lube oil synthetic or conventional SAE 10W 30 15W 30 0W 30 0W 40 below 32 F Oil Capacity 33 8 fl oz 1 0 L Fuel tank capa...

Страница 42: ...r or replace any part or unit at its option Coast Distribution may request defective parts to be returned Anything replaced under warranty becomes the property of Coast Distribution To Obtain Warranty...

Страница 43: ...ystem is warranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by Coast Distribution System Inc Owner s Warranty Responsibilities As t...

Страница 44: ...injector system Engine speed control system ECU Intake manifold Engine control module Evaporative Control System Fuel tank Fuel cap Fuel strainer Fuel injector Fuel pump Fuel lines Carbon canister in...

Страница 45: ...k cap indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere 2 A carbon activated canister collects gasoline vapors from the...

Страница 46: ...E AND DAMAGE THE CHARGER LOCATE THE CHARGER AS FAR AWAY FROM THE BATTERY AS DC CABLES PERMIT k DO NOT OPERATE CHARGER IN A CLOSED IN AREA OR RESTRICT VENTILATION IN ANY WAY l CONNECT AND DISCONNECT DC...

Страница 47: ...HEN CONNECT THE NEGATIVE BLACK CHARGER CLIP TO FREE END OF CABLE v DO NOT FACE BATTERY WHEN MAKING FINAL CONNECTION vi CONNECT CHARGER AC SUPPLY CORD TO ELECTRICAL OUTLET AND vii WHEN DISCONNECTING CH...

Страница 48: ...7930 S W Burns Way Unit C Wilsonville OR 97070 www powerhouse products com This manual version applies to BCNs equal to or greater than 140915415155001 PH4000Ri E Owner s Manual Revision 2014 08 27 BC...

Отзывы: