background image

Installation / Initial Set-U

p (cont’d)

 

 

 

 

23 

Attach handle pin to 
generator frame 

1.

 

Attach lanyard to pin. 

2.

 

Attach lanyard and pin to generator frame by looping the rope around the tube 

and inserting the pin through the loop. 
 

 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

9. Propane Tank Connection 

Your generator is equipped with a propane tank holder, tank strap, and a 4 ft. propane hose assembly that 
connects your propane tank (not included) to the low pressure regulator on the generator. The pressure reducing 
regulator also ensures that the proper fuel pressure of 7 

 11 inches of water column is being supplied to the low 

pressure regulator on the generator.      

 

Position tank and 
attach 4 ft. propane 
hose assembly  

1.

 

Position tank onto propane tank holder and secure using tank strap.  

2.

 

Thread end of hose with pressure reducing regulator onto the propane tank valve.  

3.

 

Thread remaining hose end into right hand port of the low pressure regulator.   

 
 
 
 

 

 
 
 

 
 
 
 

 
 
 
 

 

Pin 

Lanyard 

Low Pressure Regulator Port  

4 ft. Propane Hose 
Assembly 

Propane 

Tank Valve 

Propane Tank 
 Holder 

Содержание 750134

Страница 1: ...ATE THE GENERATOR FROM UTILITY POWER via a UL listed transfer switch installed by a licensed electrician Otherwise back feed from the generator into the power grid could kill utility workers Fire Expl...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...Power Source 15 5 Selecting a Suitable Site 17 6 Grounding the Generator 19 7 Battery Installation 20 8 Wheel Kit Assembly 21 9 Propane Tank Connection 23 Operation 1 General Safety Rules for Operatio...

Страница 4: ...ical devices and may also result in fire You can power this generator with gasoline or propane However there are special initial hook up requirements for propane See the Specifications section of this...

Страница 5: ...this product for its intended use and assumes liability therein Contact Powerhorse Product Support at 1 866 443 2576 for any questions about the appropriate use of this generator Warranty Registration...

Страница 6: ...y Run Time 50 Load Propane Tank Size Run Time 50 Load Pressure Range 3 9 gallon 15L 10 6 hours 20 lb or 30 lb 9 1 Hours 2 2 lbs hr or 13 6 Hours 2 2 lbs hr 7 11 inches of water column 120 240 Volt Rec...

Страница 7: ...95119 Choke Decal 1 4 796376 Starting Instruction Decal 1 5 795136 Handle Decal 1 6 795126 Shock Fire Decal 1 7 795124 Ethanol Decal 1 8 795127 CPSC Decal 1 9 795123 Fire Overheating Warning 1 10 7826...

Страница 8: ...Safety Label Locations 8 17 14 1 2 5 3 4 6 7 8 9 10 11 12 16 13 15 18 19...

Страница 9: ...grip Reference 7 Fuel Gauge Fuel level indicator for gas tank Reference 8 Control Panel An electrical device that contains receptacles switches and other electrical devices Reference 9 Propane Tank H...

Страница 10: ...witch Switch actuated by a key to start and stop the engine Reference 4 Circuit Breaker 8A 12V DC Electrical device that is designed to protect the circuit from excessive current Reference 5 12V DC 8A...

Страница 11: ...portable power source or b connect to a building as a back up power source 5 Selecting a site for using the generator 6 Grounding the generator 7 Battery installation 8 Wheel kit assembly 9 Propane ta...

Страница 12: ...attage is not given on the device s nameplate the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage Watts Volts X Amps Example conversion to watts 120 Volts X 5 Amps...

Страница 13: ...all electrical devices you will be powering at the same time with the generator 2 List the greater of the running or starting wattage next to each device as obtained from the devices nameplate or Tabl...

Страница 14: ...ote All propane tanks produce gas pressure in excess of 11 water column Introduction of gas pressure into the generator in excess of 11 water column will permanently damage this product and void the w...

Страница 15: ...cy power needs If your generator will be connected to your building s electrical system it MUST ALWAYS be isolated from the utility power grid with a UL listed transfer switch installed by a licensed...

Страница 16: ...es that are located at a distance from the generator However use only UL listed outdoor rated grounded extension cords of the proper size Use Table 2 below to choose an adequately sized extension cord...

Страница 17: ...y from all air intakes Never run the generator inside any closed or semi enclosed spaces even if outdoors including homes garages basements sheds or boxes These spaces can trap poisonous gases even if...

Страница 18: ...ustible materials to catch on fire Make sure your generator s exhaust system is at least 7 feet from all combustible materials and buildings structures The engine is equipped with a spark arrester if...

Страница 19: ...the clamp to the generator grounding post which is located on the base of the generator frame to the right of the battery location 4 DO NOT connect the generator grounding post to a water pipe or a g...

Страница 20: ...void shock and contact with the acid and to prevent any sparking that could lead to an explosion ALWAYS follow the general battery safety rules and instructions listed below General Battery Safety Rul...

Страница 21: ...Slide 1 Axle into the end of the Wheel 1 2 Slide 1 Axle Washer onto the Axle 3 Slide the Axle Wheel and Washer assembly into the Frame 4 Insert 1 Hairpin in the holes on that end of the Axle to secure...

Страница 22: ...22 Installing bushings into handle 1 Insert 2 Bushings into Handle Installing the handle 2 Attach 1 Handle to 1 Generator Frame Secure using 2 M8 x 40mm Flange Bolt and 2 M8 Flange Nut Bushing Handle...

Страница 23: ...w pressure regulator on the generator The pressure reducing regulator also ensures that the proper fuel pressure of 7 11 inches of water column is being supplied to the low pressure regulator on the g...

Страница 24: ...ained adults should set up and operate the generator DO NOT let children operate Intended use Carefully read about and understand the intended use of this generator DO NOT use for other purposes as un...

Страница 25: ...equipment while standing in water while barefoot while hands are wet or while in the rain or snow Electric shock may result Ground fault circuit interrupter Always use a ground fault circuit interrupt...

Страница 26: ...e and retain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or pla...

Страница 27: ...c shock hazard Always ensure generator is properly grounded to prevent electrical shock Perform scheduled maintenance as needed Make sure that any regular maintenance has been performed as prescribed...

Страница 28: ...Before starting review the following general safety precautions for fueling a Never pump gasoline directly into the generator s gas tank at a gas station high velocity flow from the pump could result...

Страница 29: ...s splashes immediately a If possible move the generator away from spilled gasoline on the ground b Wipe up spilled gasoline and wait 5 minutes for excess gasoline to evaporate before starting engine c...

Страница 30: ...an odorant added rotten egg sulfur smell that will aid in the detection of more dangerous quantities of leaking gas Note Propane is heavier than air and tends to settle in low areas Smell next to the...

Страница 31: ...ap if engine is running or still hot Let cool at least 2 minutes b Check engine oil level each time you refuel c Change oil after the first 20 operating hours and at least every 100 operating hours th...

Страница 32: ...DO NOT connect any loads 2 Use data meter on control panel to check generator output or use a voltage meter to check output voltage at the generator s outlets receptacles 3 Measured voltage should be...

Страница 33: ...as refrigerators freezers air conditioners or small hand tools one at a time Let each motor stabilize before connecting the next device b Connect any lights you are planning on powering Connect voltag...

Страница 34: ...ghts even if the generator s fuel tank is empty Residual fuel in the tank could ignite Away from extreme high or low temperatures Note DO NOT store with battery charger always connected Batteries that...

Страница 35: ...erator and will void the warranty Transporting Ensure the engine switch is OFF Ensure the fuel valve is OFF DO NOT leave generator inside an enclosed vehicle for an extended period of time and or oper...

Страница 36: ...end of generator to roll generator towards desired location WARNING The generator is heavy You can be injured when trying to lift it without assistance It can crush and cause serious injury if it drop...

Страница 37: ...h a Engine speed too high a Bring generator to a qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Plannin...

Страница 38: ...e exhaust system fuel tanks or fuel lines Carbon monoxide poisoning fire or explosion could result Guards DO NOT operate generator unless all guards and cover shields which prevent access to moving pa...

Страница 39: ...e on a dry surface under an open canopy like structure CO alarms Ensure that working battery operated or battery back up carbon monoxide alarms are used in any dwelling structure that is in close prox...

Страница 40: ...upply smell for gas or bad odor before starting engine If you do smell gas or a bad odor DO NOT start engine DO NOT light a match DO NOT flip on an electrical switch Exit area immediately and call pro...

Страница 41: ...oline shut off valve is in the OFF position Turn off propane tank valve as applicable Prevent accidental starting When generator is not in use remove spark plug wire in order to ensure that generator...

Страница 42: ...opened and closed by operating the choke lever manually Move choke lever to the left toward CLOSED to enrich the mixture for cold starting 4 Engine Switch Engine Key Switch Turn the engine switch to S...

Страница 43: ...ead Clean After every 500Hrs 2 Fuel tank and filter Clean Every 2 years replace if necessary 2 Fuel tube Check Every 2 years replace if necessary 2 Engine oil recommendations CAUTION Engine damage The...

Страница 44: ...Spark plug removal cleaning and replacement Proper spark plug clearance ensures the engine s normal running 1 Remove the spark plug cap 2 Remove the spark plug using the supplied spark plug wrench WA...

Страница 45: ...t up if too much oil is left in the air cleaner element 4 Re install the air cleaner element and the cover Note Do not use pressurized air or solvents to clean the filter Pressurized air can damage th...

Страница 46: ...connect spark plug wire and remove spark plug using provided spark plug wrench 6 Add one teaspoon oil through spark plug hole 7 Place rag over spark plug hole and turn starter or pull the recoil a few...

Страница 47: ...zed to help correct air fuel mixture at altitude To order a high altitude kit or if you have additional questions go to www northerntool com or contact us at 1 866 443 2576 Powerhorse Please note engi...

Страница 48: ...750134 Parts Explosion Rev B 1 48...

Страница 49: ...3 Kit 11 Kit 14 Kit 19 BOLT M6X12 6 56 Kit 6 HANDLE DAMPING BRACKET 2 22 Kit 14 DUSTPROOF SHEET 1 57 Kit 8 CONNECTING PIPE 1 23 Kit 14 BRACKET AIR CLEANER 4 58 Kit 8 MANUAL CHOKE ASSY 1 24 Kit 3 PACKI...

Страница 50: ...750134 Parts Explosion Rev B 1 50 Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Kit 6 Kit 7 Kit 8 Kit 9 Kit 10 Kit 11 Kit 12 Kit 13 Kit 14 Kit 16 Kit 17 Kit 18 Kit 19 Kit 20 Kit 15...

Страница 51: ...795668 HANDLE KIT 1 8 797247 TANK KIT 1 9 795684 TANK BOLT KIT 1 10 795675 AVR KIT 1 11 797248 GROUNDING BOLT KIT 1 12 797249 BRUSH AND TERMINAL BLOCK KIT 1 13 795687 GENERATOR STUD BOLT KIT 1 14 795...

Страница 52: ...797263 Engine Parts Explosion Rev B 1 52...

Страница 53: ...t 11 COVER ASSEMBLY CRANKCASE 1 57 Kit 8 IGNITION COIL ASSY 1 19 N A CYLINDER HEAD 1 58 BOLT M6X25 2 20 N A VALVE IN 1 59 Kit 10 PACKING INTAKE 1 21 N A VALVE EXHAUST 1 60 INSULATOR CARBURETOR 1 22 N...

Страница 54: ...RECOIL KIT 1 4 795597 DRAIN BOLT KIT 1 5 797256 FUEL LINE KIT 1 6 795602 AIR CLEANER KIT 1 7 797257 OIL LEVEL KIT 1 8 797258 IGNITION COIL KIT 1 9 795596 RECOIL STARTER FAN KIT 1 10 798145 CARBURETOR...

Страница 55: ...ion of Powerhorse Powerhorse will not provide for replacement of complete products due to defective parts Any costs incurred due to replacement or repair of items outside of a Powerhorse approved faci...

Страница 56: ...56 Distributed by Northern Tool Equipment Company Inc Burnsville Minnesota 55306 www northerntool com Made in China...

Отзывы: