background image

About Your Generator 

 

                      

4

 

                         

 

 

Thank you for purchasing your Powerhorse portable generator! 

 

About Your Generator 

 

This engine-driven, portable generator is designed to provide electrical power up to 

9,000 watts 

surge (7,250 watts continuous) on gasoline and 8,100 watts surge (7,000 watts continuous) on propane.

 

 

It can supply power: 

 

1.

 

As a portable power source

.  You can plug appliances directly into the generator’s electrical 

outlets.   

2.

 

As a back-up, standby power source for a building.  A licensed electrician can connect the 

generator to your building’s electrical syste

m via the installation of an 

UL-listed transfer switch.

   

(See the “Installation & Initial Set

-

up” section of this manual to learn more about specific 

requirements and precautions relating to wiring the generator to your building’s electrical system.) 

 

 

You must select a generator adequately sized for your power needs.

   

You need to determine the power needs of all the appliances/tools you wish to power at the same time 

and choose a generator rated to provide at least that power level.  See the “Planning 

the Power Load

” 

section of this manual to determine your specific power load requirements and then compare them to this 

generator’s rated capacity.  You must not overload the generator.  Overloading will cause damage to the 

generator and attached electrical devices, and may also result in fire. 
 

You can power this generator with gasoline or propane.  

However, there are special initial hook-up requirements for propane.  See the "Specifications" section of 
this manual with regard to specific gas flow and pressure requirements.  In addition, note the following: 
You will need a minimum 100 lb. propane tank to run this generator 

 the vaporization rate is insufficient 

with smaller tank sizes.  A certified propane technician must set up the valve and hose connection 

between the propane tank and generator in accordance with all federal and local requirements.  
 

See the "Installation/Initial Set-Up:  Step 3" section of this manual for more detailed information. 

 

Be sure to read about site selection and grounding requirements for running this generator.  

More 

detailed information can be found in the 

“Installation & Initial Set

-up, Steps 5 & 6

 of this manual. 

 

 

Contact Powerhorse Product Support at 1-866-443-2576 with questions about optional 

accessories or to order parts. 

 
 

Read this Manual 

 

WARNING 

 

Improper use or maintenance of this generator can result in 

serious injury or death

 

from 

carbon 

monoxide poisoning, electric shock/electrocution, fire/explosion, or burns

  

Read this manual completely 

before using the generator and follow all instructions and safety 

rules.

 

 

Содержание 750133

Страница 1: ...ATE THE GENERATOR FROM UTILITY POWER via a UL listed transfer switch installed by a licensed electrician Otherwise back feed from the generator into the power grid could kill utility workers Fire Expl...

Страница 2: ...Hazard Signal Word Definitions 2...

Страница 3: ...Power Source 15 5 Selecting a Suitable Site 17 6 Grounding the Generator 19 7 Battery Installation 20 8 Wheel Kit Assembly 21 9 Propane Tank Connection 23 Operation 1 General Safety Rules for Operatio...

Страница 4: ...ty You must not overload the generator Overloading will cause damage to the generator and attached electrical devices and may also result in fire You can power this generator with gasoline or propane...

Страница 5: ...s equipment from original design and manufacture Before using the user shall determine the suitability of this product for its intended use and assumes liability therein Contact Powerhorse Product Sup...

Страница 6: ...Time 50 Load Propane Tank Size Run Time 50 Load Pressure Range 6 6 gallon 25L 9 6 hours 100 lb 21 7 Hours 4 6 lbs hr 7 11 inches of water column 120 240 Volt Receptacles 4 20 Amp 120V outlets NEMA 5...

Страница 7: ...95119 Choke Decal 1 4 796376 Starting Instruction Decal 1 5 795136 Handle Decal 1 6 795126 Shock Fire Decal 1 7 795124 Ethanol Decal 1 8 795127 CPSC Decal 1 9 795123 Fire Overheating Warning 1 10 7826...

Страница 8: ...Safety Label Locations 8 17 14 1 2 5 3 4 6 7 8 9 10 11 12 16 13 15 18 19...

Страница 9: ...with dipstick for checking oil level Also provides access port to fill oil Reference 11 Oil Drain Plug Bolt located on the engine crankcase that allows oil to be drained Reference 12 Low Pressure Reg...

Страница 10: ...rom excessive current Reference 4 Voltmeter Instrument used for measuring voltage in an electrical circuit Monitors voltage as produced by the generator Reference 5 Circuit Breaker 20A Electrical devi...

Страница 11: ...portable power source or b connect to a building as a back up power source 5 Selecting a site for using the generator 6 Grounding the generator 7 Battery installation 8 Wheel kit assembly 9 Propane ta...

Страница 12: ...attage is not given on the device s nameplate the wattage may be calculated by multiplying the nameplate voltage by nameplate amperage Watts Volts X Amps Example conversion to watts 120 Volts X 5 Amps...

Страница 13: ...all electrical devices you will be powering at the same time with the generator 2 List the greater of the running or starting wattage next to each device as obtained from the devices nameplate or Tabl...

Страница 14: ...mum gas flow rate of 4 6 lbs hr Note All propane tanks produce gas pressure in excess of 11 water column Introduction of gas pressure into the generator in excess of 11 water column will permanently d...

Страница 15: ...cy power needs If your generator will be connected to your building s electrical system it MUST ALWAYS be isolated from the utility power grid with a UL listed transfer switch installed by a licensed...

Страница 16: ...tlet Extension cords may be used to power devices that are located at a distance from the generator However use only UL listed outdoor rated grounded extension cords of the proper size Use Table 2 bel...

Страница 17: ...y from all air intakes Never run the generator inside any closed or semi enclosed spaces even if outdoors including homes garages basements sheds or boxes These spaces can trap poisonous gases even if...

Страница 18: ...ustible materials to catch on fire Make sure your generator s exhaust system is at least 7 feet from all combustible materials and buildings structures The engine is equipped with a spark arrester if...

Страница 19: ...the clamp to the generator grounding post which is located on the base of the generator frame to the right of the battery location 4 DO NOT connect the generator grounding post to a water pipe or a g...

Страница 20: ...void shock and contact with the acid and to prevent any sparking that could lead to an explosion ALWAYS follow the general battery safety rules and instructions listed below General Battery Safety Rul...

Страница 21: ...Slide 1 Axle into the end of the Wheel 1 2 Slide 1 Axle Washer onto the Axle 3 Slide the Axle Wheel and Washer assembly into the Frame 4 Insert 1 Hairpin in the holes on that end of the Axle to secure...

Страница 22: ...22 Installing bushings into handle 1 Insert 4 Bushings into Handle Installing the handle 2 Attach 1 Handle to 1 Generator Frame Secure using 2 M8 x 45mm Flange Bolt and 2 M8 Flange Nut Bushing Handle...

Страница 23: ...ank not included to the low pressure regulator on the generator The pressure reducing regulator also ensures that the proper fuel pressure of 7 11 inches of water column is being supplied to the low p...

Страница 24: ...ained adults should set up and operate the generator DO NOT let children operate Intended use Carefully read about and understand the intended use of this generator DO NOT use for other purposes as un...

Страница 25: ...equipment while standing in water while barefoot while hands are wet or while in the rain or snow Electric shock may result Ground fault circuit interrupter Always use a ground fault circuit interrupt...

Страница 26: ...e and retain static electric charge as can objects made of conductive material e g metal water if they are not electrically grounded The static electric charge on an object such as a human body or pla...

Страница 27: ...c shock hazard Always ensure generator is properly grounded to prevent electrical shock Perform scheduled maintenance as needed Make sure that any regular maintenance has been performed as prescribed...

Страница 28: ...Before starting review the following general safety precautions for fueling a Never pump gasoline directly into the generator s gas tank at a gas station high velocity flow from the pump could result...

Страница 29: ...e spills splashes immediately a If possible move the generator away from spilled gasoline on the ground b Wipe up spilled gasoline and wait 5 minutes for excess gasoline to evaporate before starting e...

Страница 30: ...an odorant added rotten egg sulfur smell that will aid in the detection of more dangerous quantities of leaking gas Note Propane is heavier than air and tends to settle in low areas Smell next to the...

Страница 31: ...p if engine is running or still hot Let cool at least 2 minutes b Check engine oil level each time you refuel c Change oil after the first 20 operating hours and at least every 100 operating hours the...

Страница 32: ...DO NOT connect any loads 2 Use data meter on control panel to check generator output or use a voltage meter to check output voltage at the generator s outlets receptacles 3 Measured voltage should be...

Страница 33: ...as refrigerators freezers air conditioners or small hand tools one at a time Let each motor stabilize before connecting the next device b Connect any lights you are planning on powering Connect voltag...

Страница 34: ...ghts even if the generator s fuel tank is empty Residual fuel in the tank could ignite Away from extreme high or low temperatures Note DO NOT store with battery charger always connected Batteries that...

Страница 35: ...erator and will void the warranty Transporting Ensure the engine switch is OFF Ensure the fuel valve is OFF DO NOT leave generator inside an enclosed vehicle for an extended period of time and or oper...

Страница 36: ...end of generator to roll generator towards desired location WARNING The generator is heavy You can be injured when trying to lift it without assistance It can crush and cause serious injury if it drop...

Страница 37: ...h a Engine speed too high a Bring generator to a qualified technician for adjustment Generator overheating a Generator is overloaded b Insufficient ventilation a Reduce the load See Power Load Plannin...

Страница 38: ...e exhaust system fuel tanks or fuel lines Carbon monoxide poisoning fire or explosion could result Guards DO NOT operate generator unless all guards and cover shields which prevent access to moving pa...

Страница 39: ...e on a dry surface under an open canopy like structure CO alarms Ensure that working battery operated or battery back up carbon monoxide alarms are used in any dwelling structure that is in close prox...

Страница 40: ...upply smell for gas or bad odor before starting engine If you do smell gas or a bad odor DO NOT start engine DO NOT light a match DO NOT flip on an electrical switch Exit area immediately and call pro...

Страница 41: ...oline shut off valve is in the OFF position Turn off propane tank valve as applicable Prevent accidental starting When generator is not in use remove spark plug wire in order to ensure that generator...

Страница 42: ...opened and closed by operating the choke lever manually Move choke lever to the left toward CLOSED to enrich the mixture for cold starting 4 Engine Switch Engine Key Switch Turn the engine switch to S...

Страница 43: ...ead Clean After every 500Hrs 2 Fuel tank and filter Clean Every 2 years replace if necessary 2 Fuel tube Check Every 2 years replace if necessary 2 Engine oil recommendations CAUTION Engine damage The...

Страница 44: ...Spark plug removal cleaning and replacement Proper spark plug clearance ensures the engine s normal running 1 Remove the spark plug cap 2 Remove the spark plug using the supplied spark plug wrench WA...

Страница 45: ...t up if too much oil is left in the air cleaner element 4 Re install the air cleaner element and the cover Note Do not use pressurized air or solvents to clean the filter Pressurized air can damage th...

Страница 46: ...connect spark plug wire and remove spark plug using provided spark plug wrench 6 Add one teaspoon oil through spark plug hole 7 Place rag over spark plug hole and turn starter or pull the recoil a few...

Страница 47: ...zed to help correct air fuel mixture at altitude To order a high altitude kit or if you have additional questions go to www northerntool com or contact us at 1 866 443 2576 Powerhorse Please note engi...

Страница 48: ...750133 Parts Explosion Rev B 4 48...

Страница 49: ...57 Kit 7 CONNECTING PIPE 1 23 Kit 13 BRACKET AIR CLEANER 4 58 Kit 7 MANUAL CHOKE ASSY 1 24 Kit 19 GASKET EXHAUST PIPE 1 59 Kit 7 GASKET MANUAL CHOKE ASSY 1 25 Kit 4 COTTER PIN 2 60 Kit 7 CLIP FUEL LI...

Страница 50: ...750133 Parts Explosion Rev B 4 50 Kit 1 Kit 2 Kit 3 Kit 4 Kit 5 Kit 6 Kit 7 Kit 8 Kit 9 Kit 10 Kit 11 Kit 12 Kit 13 Kit 14 Kit 15 Kit 16 Kit 17 Kit 18 Kit 19...

Страница 51: ...68 HANDLE KIT 1 7 797269 TANK KIT 1 8 795684 TANK BOLT KIT 1 9 795736 AVR KIT 1 10 797248 GROUNDING BOLT KIT 1 11 797270 BRUSH AND TERMINAL BLOCK KIT 1 12 795741 GENERATOR STUD BOLT KIT 1 13 795720 AI...

Страница 52: ...797283 Engine Parts Explosion Rev B 4 52...

Страница 53: ...DER HEAD 1 67 Kit 11 PACKING INTAKE 1 22 N A VALVE IN 1 68 Kit 11 INSULATOR CARBURETOR 1 23 N A VALVE EXHAUST 1 69 Kit 11 PACKING CARBURETOR 1 24 N A RETURNER INTAKE VALVE 2 70 Kit 6 Kit 11 SPACER CAR...

Страница 54: ...795629 DRAIN BOLT KIT 1 5 795630 RECOIL KIT 1 6 795632 AIR CLEANER KIT 1 7 797399 OIL LEVEL KIT 1 8 795639 EXHAUST KIT 1 9 797278 IGNITION COIL KIT 1 10 795636 RECOIL STARTER FAN KIT 1 11 798146 CARB...

Страница 55: ...he sole decision of Powerhorse Powerhorse will not provide for replacement of complete products due to defective parts Any costs incurred due to replacement or repair of items outside of a Powerhorse...

Страница 56: ...56 Distributed by Northern Tool Equipment Company Inc Burnsville Minnesota 55306 www northerntool com Made in China...