Horizontal Tankmount Duplex (continued)

Ref # Description

IBVD040

IBVD050

IBVD075

IBVD100

Qty

1

Control Panel 

208V

230V

460V

PVI29T42BB

PVI29T43BB

PVI29T44BB

PVI29T52BB

PVI29T53BB

PVI29T54BB

PVI29T72BB

PVI29T73BB

PVI29T74BB

PVI29TA2BB

PVI29TA3BB

PVI29TA4BB

1

2

Vacuum/Pump Motor Assembly

208-230/460V

VPB05004AV

VPB05005AV

VPB07501AV

VPB10001AV

2

3

Vacuum Switch (not shown)

VP001303AV

VP001303AV

VP001303AV

VP001303AV

2

4

Inlet Air Filter Element

VP000539AV

VP000504AV

VP000504AV

VP000504AV

1

5

Receiver Tank*

120 gal

200 gal

240 gal

AR022800ST

-

-

AR022800ST

JQ000200ST

-

-

JQ000200ST

-

-

JQ000200ST

AR069500AV

1

6

Check Valve

VP000405AV

VP000407AV

VP000407AV

VP000407AV

2

7

Vacuum Hose (specify length when 

ordering)

HA001304AV

HA001302AV

HA001302AV

HA001302AV

2

8

Vacuum Gauge

ST073334AV

ST073334AV

ST073334AV

ST073334AV

2

9

Hour Meter

PE001004AV

PE001004AV

PE001004AV

PE001004AV

2

10

Oil

Part# AM00406AV for all 

pumps**

2.7 qts/pump

3.7 qts/pump

7 qts/pump

7 qts/pump

11

Oil Filter

0531.000.002

0531.000.002

0531.000.001

0531.000.001

1 filter/

pump

12

Exhaust Filter

0532.917.861

Qty = 2/pump

0532.140.159

Qty = 2/pump

0532.140.159

Qty = 4/pump

0532.140.159

Qty = 4/pump

* Tank part numbers listed in the table are not lined. For lined tanks, replace ST with LW at the end of the part 

number. The AR069500AV 240 gallon tank is lined

** Part Number AM00406AV is for one gallon of oil. End user must follow the recommended quantity for each 

pump

Содержание IBVD0153 Series

Страница 1: ...599500AV 20 October 2020 Page 1 of 20 Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others...

Страница 2: ......

Страница 3: ...0 77 212 200 H 21675 Duplex IBVD0153xx 3 1 5 2 14 36 80 H 6502 IBVD0203xx 4 2 2 22 56 80 H 8670 IBVD0303xx 6 3 2 34 90 80 H 13006 IBVD0304xx 6 3 2 34 90 120 H 13006 IBVD0404xx 10 5 2 50 142 120 H 2167...

Страница 4: ...y Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may cause damage to equipm...

Страница 5: ...the receiver and process lines when the pumps are turned off Intake Filters The intake filters protect against particulates that could damage the pumps Elements are replaceable and are design to resi...

Страница 6: ...be required All other sides 24 in 5 If necessary use metal shims or leveling pads to level the compressor tank or basemount unit Never use wood to shim the unit 6 The unit has mounting holes to allow...

Страница 7: ...pipe needed from the flex connector to the final outlet plus a factor for each elbow cross or tee Pipe must be smooth ID If rough pipe is used increase by one size The IBVS and IBVD systems do not ha...

Страница 8: ...rs etc are properly sized 6 Make sure inlet filter is properly installed 7 Close drain valve Risk of injury Make sure no one is in contact with any moving parts during the rotation check Start Up Oper...

Страница 9: ...uire more frequent changing of separator filters If exhaust stream contains significant oil or if the pressure in the crankcase is higher than normal follow instructions in the pump manual 5 If oil in...

Страница 10: ...Air Filter Element VP000539AV VP000539AV VP000539AV 1 5 Receiver Tank 30 gal 60 gal 80 gal AR024200ST AR231600ST AR231600ST AR063000ST 1 6 Check Valve VP000405AV VP000405AV VP000405AV 1 7 Vacuum Hose...

Страница 11: ...VP000539AV VP000504AV VP000504AV VP000504AV 1 5 Receiver Tank 80 gal 120 gal 200 gal AR023400ST AR023400ST AR022400ST AR022400ST JQ000200ST 1 6 Check Valve VP000405AV VP000407AV VP000407AV VP000407AV...

Страница 12: ...VP000504AV VP000504AV 1 5 Receiver Tank 80 gal 120 gal AR022900ST AR022900ST AR022900ST AR022800ST 1 6 Check Valve VP000407AV VP000407AV VP000407AV 2 7 Vacuum Hose specify the length when ordering HA...

Страница 13: ...Tank 120 gal 200 gal 240 gal AR022800ST AR022800ST JQ000200ST JQ000200ST JQ000200ST AR069500AV 1 6 Check Valve VP000405AV VP000407AV VP000407AV VP000407AV 2 7 Vacuum Hose specify length when ordering...

Страница 14: ...on OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN599500AV 20 October 2020 Page 14 of 20 Industrial Vacuum Tankmount Systems Operating Maintenance Manual Vacuum System Flow Schemati...

Страница 15: ...Purge System Flow Schematic Operation of the Auto Purge System The Powerex control will close the isolation solenoid and open the purge solenoid when Auto purge is active This will allow fresh clean...

Страница 16: ...150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN599500AV 20 October 2020 Page 16 of 20 Industrial Vacuum Tankmount Systems Operating Maintenance Manual...

Страница 17: ...ial Vacuum Tankmount Systems Operating Maintenance Manual Powerex 150 Production Drive Harrison OH 45030 USA P 1 888 769 7979 F 513 367 3125 www powerexinc com IN599500AV 20 October 2020 Page 17 of 20...

Страница 18: ...d Powerex shall be fully liable for all Defects in the Products the Product Defects i e all costs of repair or replacement which may include in and out charges so long as the Products are located in t...

Страница 19: ...fter any initial warranty period has expired or where another warranty does not apply for any reason Powerex warrants that such replacement parts will be free from Defects for the first twelve 12 mont...

Страница 20: ...y with them Claims Any non warranty claims pertaining to the Products must be filed with Powerex within 6 months of the invoice date or they will not be honored Prices discounts and terms are subject...

Отзывы: