Do not connect devices that draw either massive power shortly or half-wave rectified current - such as 

hairdryer, vacuum cleaner, laser printer, and plotter. 

Note

:  Although  you  may  use  the  UPS  immediately,  maximum  back  up  time  will  not  be  available  yet.  It  is 

recommended to charge the batteries for a minimum of 8 hours before use. 

 

Connect  the  input cable  to  the  UPS and  the  other end  to the mains. The battery will automatically 

charge when connecting to the main power. 

 

Connect the loads to the UPS; Ensure receptacles are connected firmly. 

 

(Optional)  To  protect  your  telecom/internet  system,  use  RJ45/RJ11  cable  to  install  the  input/output 

cable with matching in/out jack. 

4.

 

Operation 

Necessary  information  for  the  operation  of  the  unit  is  covered  in  this  chapter.  Normally  UPS  runs 

automatically, but on a few occasions such as just after installation, all procedures are described herein. 

4.1 General Description 

As Line-Interactive UPS, it is capable of providing clean and stable power to your critical system. While the 

UPS regulates and filters power fluctuation, it also keeps the battery charged for any emergency.

 

 

Automatic transformer regulates over and under-voltage power.

 

 

During a power failure, the UPS immediately provides backup power from the battery to support 

your essential equipment.

 

 

Power transference is typically achieved uninterrupted within 4 milliseconds.

 

Line-Mode/Battery-Mode 

UPS  will  operate  in  Line-Mode  that  supports  power  and  charge  battery  while  connected  to  power. 

During a power failure, the UPS will switch to Battery-Mode, in which power is maintained from the battery. 

In case of failure time exceed. 

Battery-Mode duration, UPS will shut down until voltage return to prevent battery discharge. 

Diagnostic Test

 

While  the  advanced  battery  management  system  monitors  the  conditions  of  the  batteries,  it  sends 

early warnings if a battery replacement is needed. Diagnostic tests can be performed from the control panel. 

4.2 System Configuration 

The UPS device and battery make up the system. Depending on site and load requirements, certain 

additional options are available as tailored solutions. Please consider the following when planning your UPS 

system: 

 

The  total  demand  for  the  protected  system  shall  dictate  the  output  power  rating  (VA).  When 

measuring demand, please allow a margin for future expansion and calculation error. 

 

Battery-mode  duration  needs  dictate  the  battery  size.  If  the  load  is  less  than  the  UPS  nominal 

power rating, then the actual backup time is longer.

 

4.3 UPS Control

 

Control panel functions 

Display     

Function Description 

Display 

Function Description 

LED Display 

 

Line Mode(Green) 

UPS operating with Main power 

 

Overload(Red) 

Load exceed UPS capacity

 

 

Battery Mode(Yellow) 

UPS operating with battery power 

Output Voltage 

Displaying UPS output voltage 

 

Battery Fault(Red) 

Battery Fault/Overload occurred 

Battery Replacement: steady light 

  Charger Failure: steady light 

Overload: Rapid flash 

 

Battery Level 

Display battery remaining During 

battery or charger failure, the 

indicator will flash along with the 

fault indicator 

Button Display 

 

ON/OFF/TEST/Silence Button 

The master button for UPS control, refer to Button Operation

 

Button operation 

Cold Start function 

When the main power is disconnected from UPS, it is capable of starting with battery power for users’ 

needs. Simply start the UPS as the instruction below. 

  “On/Off/Test/Silence” button 

Turn on the UPS 

 

Switch on the Load 

 

Press the "ON" button until a single "beep" alarm disappeared or the LED display turns on. 

Shut Down the UPS

 

 

Switch off the Load 

 

Press the "OFF" button for 3 seconds during Line/Battery-mode. 

Содержание 425A/AP

Страница 1: ...e 425VA 1000VA IMD 1000AP IMD 1000A IMP 1000AP IMP 1000A IMD 825AP IMD 825A IMP 825AP IMP 825A IMD 625AP IMD 625A IMP 625AP IMP 625A IMD 525AP IMD 525A IMP 525AP IMP 525A IMD 425AP IMD 425A IMP 425AP...

Страница 2: ...ance Declaration of Conformity Request Units labelled with a CE mark comply with the following stander and directives EMC Directive 2014 30 EU LVD Directive 2014 35 EU Safety EN 62040 1 EMC EN 62040 2...

Страница 3: ...to direct sunlight or high heat source DO NOT block off ventilation opening around the housing CAUTION Before conducting maintenance repair or shipment please turn off everything completely and discon...

Страница 4: ...voltage may exist at battery terminals and ground test for safety before any direct contact CAUTION Remove the battery s pole during service inside the battery cabinet or UPS CAUTION ONLY replace bat...

Страница 5: ...hut down until voltage return to prevent battery discharge Diagnostic Test While the advanced battery management system monitors the conditions of the batteries it sends early warnings if a battery re...

Страница 6: ...USB port on UPS Connect with factory provided Ensure your computer can install and support power management software 6 Maintenance Please read the following instruction to ensure your safety and maint...

Страница 7: ...el free to contact for technical assistance PROBLEM POSSIBLE CAUSE Solutions UPS can t operate switching on No lights on no warning sound Power source mistake or low battery power Check the main power...

Страница 8: ...ication RJ11 RJ45 AP model Battery Type 12V 7 2Ah 12V 9 Ah Quantity 1 1 Typical Recharge Time 6 8 hr to 90 Management Communication Indicator LED Control Panel IMP model Digital Control Panel IMD mode...

Отзывы: