background image

APPLIANCE WATTAGE REFERENCE GUIDE

*Wattages listed, both Rated and peak are approximate only; check tool or       

   appliance for actual Wattage, both Rated and Peak.

STOPPING THE GENERATOR

1. Turn OFF and disconnect all electrical loads from

generator panel outlets. NEVER start or stop engine

with electrical devices plugged in and turned ON.

2. Let engine run at a no-load speed for several 

minutes to stabilize internal temperatures of the 

 

 

engine and generator.

APPLIANCE WATTAGE REFERENCE GUIDE

26

25

Tool or Appliance

Rated 

(Running) Watts

Additional Peak

(Starting) Watts

Deep Freezer

500

1000

Sump Pump

800

1600

Refrigerator/Freezer – 18 cf

800

1600

Water Well Pump – 1/3 HP

250

500

Window AC – 10,000 BTU

1200

2400

Window Fan

300

600

Furnace Fan Blower – 1/2 HP

375

750

DVD/CD Player

100

VCR

100

Stereo Receiver

450

Color Television – 27 in.

500

Personal Computer 

w/ 17 in. Monitor

800

Microwave Oven 

1000 Watt

1000

Coffee Maker

1500

Electric Range 

Single Element

1500

Hot Plate

2500

Security System

180

AM/FM Clock Radio

300

Tool or Appliance

Rated 

(Running) Watts

Additional Peak

(Starting) Watts

Garage Door Opener – 1/2 HP

480

960

Electric Water Heater – 40 gal

4000

Quartz Halogen Work Light

1000

1600

Airless Sprayer – 1/3 HP

250

500

Reciprocating Saw

750

960

Electric Drill –  3/8 in.

 

500

750

Circular Saw – 7-1/4 in.

1000

2000

Miter Saw – 10 in.

1500

3000

Table Planer – 6 in

1000

1800

Table Saw/Radial 

Arm Saw – 10 in.

2000

4000

Air Compressor – 1-1/2 HP

1150

2300

3. Push engine rocker switch to “OFF” position. 
4. Turn petrol valve to “OFF” (clockwise) position.

AC 240V/50Hz

15A

21A

Содержание 5000W

Страница 1: ...NGS INSTRUCTIONS AND PRODUCT LABELS FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE COPYRIGHT 2010 ALLTRADE TOOLS LLC 1431 VIA PLATA LONG BEACH CA 90810 1462 USA EGS0249 5000 6000 WATT 13 HP Generator _Rev 10 10 10 Printed in China 5000 6000W GENERATOR INSTRUCTION MANUAL EGS0249 R U O H E M R E T H U O S R 1 0 1 AC 240V 50Hz 15A 15A 26A ...

Страница 2: ...di tions and practices that may occur when operating maintaining and cleaning power tools Always use common sense and pay particular attention to all the DANGER WARNING CAUTION and NOTE statements in this manual This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death TABLE OF CON...

Страница 3: ...headers marked DANGER or WARNING These same precautions are placed as labels on the tool itself NEVER use this generator for applications that are NOT specified in this manual DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury ...

Страница 4: ...ed personnel may result in a risk of injury Do not use the tool if the power switch does not turn it ON or OFF A tool that cannot be controlled with the switch is dangerous and must be repaired Store all maintenance tools away from the immediate area before turning ON the tool Do not overreach Proper footing and balance is a must at all times while using tools Unstable support may lead to personal...

Страница 5: ...are They will function better and more safely when kept clean and in good working condition Keeping the tool clean dry and free of grime will add to its life and performance Do not use the tool for applications other than specified SAFETY RULES FOR PETROL ENGINES Carbon monoxide is a product of incomplete combustion such as exhaust fumes from the engine Carbon monoxide is colorless odorless and ta...

Страница 6: ...arts of the engine where damage can result from sparking Replace a defective spark plug only with authorized parts Use approved spark plug tester DO NOT overfill petrol tank Leave ample space for expansion of petrol DO NOT start engine in area of petrol spillage Fire and explosion can occur Keep petrol away from sparks open flames pilot lights heat and other ignition sources DO NOT smoke while ope...

Страница 7: ...ammable liquids gases or dust Generators can cre ate sparks which may ignite the dust or fumes Never use the generator in damp or wet locations Wear proper apparel Remove your jewellery before using generator Do not wear loose clothing necklaces rings bracelets or other jewllery which may get caught in moving parts Nonskid footwear and electrically non conductive gloves are highly suggested while ...

Страница 8: ... ventilation DO NOT place generator in an area Where there is evidence of oil or petrol leaks Where flammable petrol vapors or materials may be present Where extremely dirty air or water could be drawn into the generator RISK OF INJURY High voltage is used in the operation of this equipment Death on contact may result if safety precautions are not observed Whenever possible keep one hand from touc...

Страница 9: ...d following the procedure in the assembly illustration Make sure all hardware is tightened properly 4 After completion of the assembly carefully place the generator on its wheels and legs 5 Lift the handle and move the generator on a flat surface to verify proper wheel and handle assembly FUNCTIONAL DESCRIPTION GENERATOR FEATURES 1 Handle Kit 2 Petrol Tank 3 Petrol Tank Cap 4 Petrol Gauge 5 Choke ...

Страница 10: ...nd allow any spilled petrol to evaporate before starting engine DO NOT over tighten handles on generator frame Handles must be allowed to move up and down with ease but not too loose as to rattle during operation of the generator PREPARING THE GENERATOR Improper treatment of generator can damage internal components and shorten the life of unit ADDING ENGINE OIL 1 Move the generator OUTSIDE and pla...

Страница 11: ... from power utility can result in serious injury or death to electric utility workers due to backfeed of electrical energy Do not connect the gener ator directly into your home s electrical system through a receptacle outlet Connections to a building s electrical system for usage as standby power must be provided by a qualified electrician All connections must isolate generator power from utility ...

Страница 12: ...oisture dust dirt or corrosive vapors DO NOT operate generator in rain DO NOT allow unqualified persons to operate or maintain generator SHUT GENERATOR OFF IF Electrical Output is lost Various components spark smoke or emits flames Generator vibrates excessively OUTLETS AND CIRCUIT PROTECTORS Overloaded electrical cords can overheat arc and burn resulting in property damage severe burns and even d...

Страница 13: ...iances or tools connected to it Exceeding generators wattage amperage capacity can damage generator and or any electrical devices connected to it Improper treatment of generator can damage internal components and shorten the life of unit Exhaust heat gases can ignite combustible materials structures or damage to petrol tank resulting in fire Keep at least 1 5 m clearance on all sides of generator ...

Страница 14: ...Window AC 10 000 BTU 1200 2400 Window Fan 300 600 Furnace Fan Blower 1 2 HP 375 750 DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 in 500 Personal Computer w 17 in Monitor 800 Microwave Oven 1000 Watt 1000 Coffee Maker 1500 Electric Range Single Element 1500 Hot Plate 2500 Security System 180 AM FM Clock Radio 300 Tool or Appliance Rated Running Watts Additional Peak Starting Wa...

Страница 15: ...arning can result in severe burns MAINTENANCE Regular maintenance will improve performance and extend life of generator Generator s warranty does not cover items that have been subjected to operator abuse or negligence Only by maintaining generator in accordance with instructions in this manual will the full value of the warranty be honored HOUR METER This meter displays the values for engine tota...

Страница 16: ...storage 2 Remove the spark plug from the cylinder Wipe oil from the spark plug and return it to the cylinder and retighten 3 Reconnect the spark plug wire Engine components should be kept clean reducing risk of overheating and ignition of accumulated debris Use a damp cloth to wipe exterior surfaces clean Use a soft bristle brush to loosen caked on dirt or oil Use a shop vacuum to pick up any loos...

Страница 17: ...cate the generator 4 Contact authorized service facility Cannot shut off Engine 1 Faulty generator circuits or parts 1 Contact authorized service facility Problem Probable Cause Solution Engine lacks power 1 Load is too high 2 Dirty air cleaner 1 Check capacity and refer to Wattage Guide 2 Replace air filter Engine hunts or falters 1 Carburetor is running too rich or too lean 1 Contact authorized ...

Страница 18: ...om mend that you keep the original product packaging in the event you need to ship the unit We suggest the package be insured against loss or in transit damage When sending your product include your name address phone number e mail address dated proof of purchase or copy and a statement about the nature of the problem Warranty coverage is conditioned upon purchaser furnishing Alltrade with adequat...

Страница 19: ...e purchaser Alltrade shall not be responsible or liable for any expense including freight charges or repairs made outside Alltrade s facility or an Alltrade designated service unless expressly agreed to by Alltrade in writing Under no circumstances shall Alltrade bear any responsibility for loss of the unit loss of time or rental inconvenience commercial loss or consequential damages This warranty...

Отзывы: