5.  BUS-OPERATION, P²-SERVOBRIDGE SET-UP FACILITIES

Various methods can be employed to set up and adjust the P²-ServoBridge.  

A greater or lesser quantity of data can be transferred depending on the bus system 

in use. Several systems allow the P²-ServoBridge to be set up from the transmitter.
The table below provides an overview of the integral functions:

Radio control system

Application

Telemetry

Servo bus

Set-up

PowerBox P²-BUS

Current, voltage, capacity, 

temperature, peak and 

average current, status

Radial and parallel

addressed telemetry

26 channels

At the transmitter 

itself

Royal SR2

Competition SR 2

Full servo telemetry only 

in conjunction with Core 

and Atom

P²-BUS

Radial and parallel

addressed telemetry

26 channels

At the PowerBox 

Data socket via the 

P²-BUS menu

Jeti EX-Bus

Current, voltage, capacity, 

temperature, peak and 

average current

One Bridge per EX-BUS 

output

24 channels

At the transmitter 

itself

Futaba S.BUS 2

Current, voltage, capacity, 

temperature

Radial and parallel

addressed telemetry

Max. 7 Bridges,

16+2 channels

USB interface and 

PC-Terminal

SRXL/UDI

None

Radial

16 channels

USB interface and 

PC-Terminal

PWM Servo signal

None

None

USB interface and 

PC-Terminal

Содержание P2-SERVOBRIDGE

Страница 1: ...INSTRUCTION MANUAL P2 ServoBridge...

Страница 2: ...Additional data including peak current or average current are helpful in optimising the adjustable fuse When used with the PowerBox Core and Atom and also with Jeti radio control systems all the devi...

Страница 3: ...able at the transmitter with PowerBox and Jeti radio control systems Unrestricted choice of bus channel Variable PWM frame rate 12ms 14ms 16ms and 18ms Accurately adjustable electronic fuse Automatic...

Страница 4: ...surface on the servo As this ensures optimum temperature measurement To transfer the temperature of the servo case to the sensor of the P ServoBridge apply a small amount of heat conducting paste to...

Страница 5: ...e of the servo to suit the installation in your model 3 Now connect the output of the ServoBridge to the servo input socket 4 To minimise losses between the P ServoBridge and the servo we recommend th...

Страница 6: ...lect the channel to be derived from the bus signal this will be generated as a PWM servo signal 2 2 FRAME RATE The frame rate refers to the speed at which the PWM signal is repeated at the ServoBridge...

Страница 7: ...ime This feature enables you to set one threshold which causes the fuse to trip if the current value is exceeded for a significant period The second threshold then swit ches the power off if a higher...

Страница 8: ...he automatic Reset function attempts to restart the consumer unit servo after it has been switched off This is accomplished by switching the fuse on again and measuring the current If the current is a...

Страница 9: ...age current status Radial and parallel addressed telemetry 26 channels At the transmitter itself Royal SR2 Competition SR 2 Full servo telemetry only in conjunction with Core and Atom P BUS Radial and...

Страница 10: ...automatically sets the address to a vacant location when you press the X Y button NOTE The sensor address is not the channel address The transmitter automatically sets the sensor address for telemetr...

Страница 11: ...TRANSMITTER WITH EX BUS You can use the JetiBox menu to set up the P ServoBridge for use with a PowerBox Royal SR2 or for operation at one of your receiver s EX BUS outputs This is accomplished by con...

Страница 12: ...g Y leads The USB interface and the Terminal PC program are used to select the slots to be used the output channel and the fuse settings The P ServoBridge is not registered at the transmitter simply a...

Страница 13: ...en channels The USB interface and PC Terminal are used to define which channel is to be generated at the output and to adjust the fuse 5 6 PWM SERVO SIGNAL The P ServoBridge can also be connected to a...

Страница 14: ...the support forum before contacting us by phone You can find the forum at the following address www forum powerbox systems com 9 GUARANTEE CONDITIONS We place particular emphasis on a high level of q...

Страница 15: ...lation instructions the conditions of the P ServoBridge or the maintenance of the entire remote control system Liability for damage and consequential damage caused by the device or the use of the same...

Страница 16: ...PowerBox Systems GmbH Ludwig Auer Stra e 5 86609 Donauwoerth Germany 49 906 99 99 9 200 49 906 99 99 9 209 www powerbox systems com 11 2021...

Отзывы: