The table below is designed to help you assign your servo to the appropriate
category:
Servo type
Servo size in mm
Output torque in kg/cm
Micro
8 – 12
2 – 7
Midi
12 - 15
8 – 15
Standard
20
15 - 25
Hi-Torque
20
25 - 60
2.4 TRIP CURRENT AND TRIP TIME
The P²-ServoBridge has two current thresholds which can be set to different valu-
es, as well as the associated trip time.
This feature enables you to set one threshold which causes the fuse to trip if the
current value is exceeded for a significant period. The second threshold then swit
-
ches the power off if a higher current peak of shorter duration occurs.
An example:
Trip current 1: 5.0A
Trip time 1:
2000ms
Trip current 2:
8.0A
Trip time 2:
500ms
The fuse switches the power off if a current of 5.0A is exceeded for at least two
seconds, and also if 8.0A is exceeded for half a second.
If you don’t wish to set two different threshold values, simply set both trip currents
and times to the same value.