8
www.powerboozt.com
omvormer inverter de Hoeve Multipower wechselrichter Mueller
EN
5.
In Operation
Check that the cables are mounted correctly. Never use the inverter when the cables are damaged. Set the
power switch to “UPS” or “ECO” position.
A warm housing is normal when the inverter is operating.
If you will not be using the inverter for a significant period (during winter storage for example), we recommend
disconnecting it from the battery.
5.1
LED indications
(
RHINO series
)
‘power’ (green) :
Battery connected and the on/off switch is in ‘on’ position
‘fault’ (red):
Fault occurred on the input side or internal temperature
‘fault’ (red, blinking):
Fault occurred on the output side.
In cause of a fault, consult the chapter ‘protections’ and the trouble shooter.
5.2
LED Indications (RHINO-L series)
“Level load” (3 colors):
when loading with 20% rated power, led not light; when loading up to 20-50% rated
power, LED green; when loading up to 50-75% rated power, LED orange; when full load up to 80-100%, LED
red
“Status “ (2 colors):
battery connected and the off/off switch is in “on “ position, LED green;
When inverter protection function occurred or fault occurred.
PowerBoozt Rhino L-B (with 230Vac Bypass function):
Switch in position ‘UPS’ means: the device prefers 230Vac from mains above Battery.
If no 230Vac from grid is detected: Device immediately starts generating from battery
to 230Vac. (UPS / Modus)
Switch in position ‘OFF’ means: Device is turned off. Possible Available 230Vac from mains will
be transferred to the AC output automatically.
Switch in position ‘ECO’ means: The device prefers 230Vac inverted from battery above
230Vac mains. If battery is empty, the Device immediately transfers 230Vac from mains to
AC output. (Reversed UPS modus)