TROUBLESHOOTING
Symptom
Possible Cause
Solution
Three-phase units only:
Platform does not rise or
lower. Motor hums, but
does not run.
No voltage is present on
one line.
NOTE: A motor that is
missing voltage on one line
is said to be single-phased.
Check for blown fuses at branch circuit disconnect.
Replace fuse. Determine cause of blown fuse.
Check motor starter as follows:
1. Disconnect wires at load side of starter.
2. Energize the starter.
3. Measure line-to-line voltage at line side of starter.
4. Measure line-to-line voltage at load side of
starter.
5. Line-side and load-side voltages should be
approximately the same. Replace starter if
voltage values are considerably different from
one another.
Check all wiring to motor for high resistance or no
connection.
Three-phase units only:
Platform does not rise.
Motor runs in reverse
Phase reversed.
Reverse any two legs at the branch circuit
disconnect.
Single-phase units only:
Platform does not rise or
lower. Motor energizes,
but does not run.
Line voltage too low.
Check wiring to motor for high resistance. Check for
loose or corroded connections. Check if gauge of
wires to motor are of correct size and specification
for load requirement. Replace if necessary.
Defective motor centrifugal
switch.
Replace motor.
Defective motor capacitor.
Replace motor.
Symptom
Possible Cause
Solution
Platform does not rise
or lower. Motor does not
energize.
Motor overload device
tripped or fuse blown.
Reset overload relay (three-phase) or replace
fuse(s) (single-phase). Determine cause of overload.
NOTE: When replacing fuse(s), the new fuse must
have the same specification as the old fuse.
Motor starter (three-
phase) or motor relay
(single-phase) not
energizing.
Check voltage at starter or relay coil.
• If voltage is present and starter or relay does not
energize, replace starter or relay.
• If voltage is not present, check all components in
series with the starter or relay coil.
Содержание VS series
Страница 40: ...38 4111 0008 April 2017 June 2017 PARTS Lip and Platform Q N I H D E F A B C G M K L O W V U J T Y X P S R ...