ADJUSTMENTS
Storage Prop Adjustment
Storage Prop Adjustments
Follow all safety precautions.
1. Raise platform fully and engage the
storage prop in the service position (If
dock leveler has not been used recently
cycle leveler once).
2. Turn OFF all electrical power to the dock
leveler. Attach safety lockout and tagout
devices.
3. Lower side maintenance props tighten all
nut 1/4 turn past finger tight.
4. Adjust yoke on storage prop till you have
minimum of 1/2” to 1“ approximately, of
movement in the storage prop.
5. When the play in the prop is correct
only 1-1/2 threads max will be exposed
through the yoke. If more threads
exposed the storage prop must be
shorted.
6. Raise side maintenance props.
7. Turn on electrical power remove lockout
tagout devices.
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete.
Max Threads Exposed 1-1/2
1/2” Min to 1” Max
Maintenance Prop
Содержание VS series
Страница 40: ...38 4111 0008 April 2017 June 2017 PARTS Lip and Platform Q N I H D E F A B C G M K L O W V U J T Y X P S R ...
Страница 44: ...42 4111 0008 April 2017 June 2017 Centra Power Hydraulic Components PARTS A B E D F G I H C ...
Страница 47: ...45 4111 0008 April 2017 June 2017 This page was left intentional left blank PARTS ...
Страница 53: ...51 4111 0008 April 2017 June 2017 PARTS This page was left intentional left blank ...
Страница 58: ...56 4111 0008 April 2017 June 2017 NOTES ...