PROBLEM

CAUSE

SOLUTION

Cylinder(s) will not retract

(1)  Check the system pressure; if
the pressure is zero, the control
valve is releasing pressure and the
problem may be in the cylinders,
(mechanical linkage connected to
cylinders), or quick-disconnect
couplings.
(2)  Defective valve

(3)  Inadequate air pressure

(1)  Check the cylinders for broken
return springs and check couplers to
insure that they are completely
coupled.  Occasionally couplers have
to be replaced because one check
does not stay open in the coupled
position.
(2)  Check valve operation and
instpect parts.  Replace if necessary.
(3)  Increase air pressure.

Pump delivers excess oil pressure

(1)  Check pressure gauge
(2)  Relief valve not properly set

(1) Calibrate gauge
(2)  Reseat the relief valve

Sheet No.

4 of 4

Rev. 3 Date: 25 May 2012

Содержание PA46 Series

Страница 1: ...nd possibly cause personal injury Hose material and coupler seals must be compatible with the hydraulic fluid used Hoses also must not come in contact with corrosive materials such as creosote Impregn...

Страница 2: ...rt a clean funnel Fill the reservoir with hydraulic oil to within 1 2 of the top of the filler hole Replace the filler cap with the breather hole open NOTE The pump has been shipped without oil in the...

Страница 3: ...with a suitable flushing oil Rinse the filter clean 4 Place the pump and motor assembly back onto the reservoir and secure it with two machine screws assembled on opposite corners of the housing 5 Co...

Страница 4: ...on the pressure regulating valve Turn the adjusting screw a few turns counterclockwise CCW to decrease the pressure setting to a lower than desired pressure Note For easy adjustment of the pressure re...

Страница 5: ...ow pressure unloading valve out of adjustment 9 Reservoir capacity is too small for the size of the cylinder s used 10 Defective directional valve 11 Sheared drive shaft key s 12 Motor rotating in wro...

Страница 6: ...lty pressure gauge 2 Check for external leakage 3 Check the external pressure regulator Check the relief valve setting 4 Look for internal leakage in double acting cylinders 5 Check for leaks in the f...