Istruzioni per l’uso e manutenzione
Cod. OQ7.5ARG114 – GB
Emiss. 19-01-11 Rev. 0 - Agg. /
38
POWER SYSTEM SRL
Via dell’Emigrante, 11/13 - 36040 Brendola (VI) Italia
17.7 MACHINE
STATUS
The machine status function is accomplished by means of a dry contact relay located on the power board.
To use this switching contact you must operate directly on the terminal board in the electric panel on the terminals C (common), NO
(normally open) and NC (normally closed); see fig.A ref.1.
The activation of this relay may influence running status, alarm status or motor rotation. These 3 functions are selected in the “
User
programming
” parameters, ref.14 – 15 – 16.
17.8 HEATING
ELEMENT
If present, the heating element is positioned in the separator tank ( fig.B ref.A) and, when the temperature is below 10°C, it starts up to
heat the oil. The temperature is detected by the oil probe.
The heating resistance (max. 125W) is connected to the terminals indicated in fig.A ref.2.
1
Fig. A
1
1
2 2
1
2
2
Fig. B
A