MAINTENANCE
Reinstall spark plug. Start the spark plug in its threads
by hand and finger-tighten.
Tighten with wrench to compress washer. If spark plug
is new, use 1/2 turn to compress washer appropriate
amount. If reusing old spark plug, use 1/8 to 1/4 turn for
proper washer compression.
NOTE:
An improperly tightened spark plug will become
very hot and could damage the engine.
CHANGING ENGINE LUBRICANT
See Figure 20.
Shut off the engine.
Clean the area around the oil drain plug, then remove the
plug.
Tilt the pressure washer on its side as shown. Drain lu-
bricant into approved container.
NOTE:
Drain the lubricant while the engine is still warm
but not hot. Warm lubricant will drain quickly and more
completely.
WARNING:
Do not change engine lubricant while it is hot. Accidental
contact with hot engine lubricant could result in serious
burns.
After the crankcase is completely drained, return the
pressure washer to an upright position.
Replace the oil drain plug.
Fill with lubricant following the instructions in
Adding/
Checking Engine Lubricant
earlier in this manual. For
amount of lubricant needed to refill, see
Product Specifi-
cations
earlier in this manual or the accompanying engine
manual, if applicable.
Before using the pressure washer, check to ensure that
no lubricant is leaking from the engine.
NOTE:
Used lubricant should be disposed of at an approved
disposal site. See your local oil retailer for more information.
PUMP MAINTENANCE
Routinely make a visual inspection of the pump. If you notice
any leaking of lubricant around the pump seals, take the
pressure washer to an authorized service center for repair.
There are no user serviceable parts to the pressure washer
pump. Any attempt to service or alter the pump may dam-
age the pressure washer and void your product warranty.
STORING THE PRESSURE WASHER
See Figure 21.
NOTE: Regular use of fuel stabilizer and pump protector
will give you better performance of the unit and increase
the life of the pump. See the Replacement Parts List for
available sizes and part numbers of these items and call
customer service at 1-877-617-3501 to order.
Allow 30 minutes of “cool down” time before storing the
machine. Store in a dry, covered area where the weather
can’t damage it.
It is important to store this product in a frost-free area. Always
empty water from all hoses, the pump, and the detergent
bucket before storing.
Drain the fuel tank completely by running the pressure
washer until the gas runs out. Stored gas can go stale in
30 days.
NOTE:
Make sure the water supply is connected and
turned on when allowing the pressure washer engine to
run.
Make sure the OFF switch and fuel valve are in the OFF
position.
Disconnect the water connection.
Empty the pump by pulling on the recoil starter about
6 times. This should remove most of the liquid from the
pump.
NOTICE:
The use of a pump protector is strongly recommended
after each use and before storing to prevent cold weather
and seal damage during storage.
Drain the lubricant and replace with fresh, clean lubricant
as described in
Adding/Checking Engine Lubricant
in
the
Operation
section of this manual.
Disconnect spark plug wire and remove the spark plug.
Pour about a teaspoon of clean, air-cooled, four-cycle
lubricant through the spark plug hole into the combustion
chamber.
Leaving the spark plug out, pull the starter cord two or
three times to coat the inside of the cylinder wall.
Inspect the spark plug and clean or replace, as necessary.
Reinstall the spark plug, but leave the spark plug wire
disconnected.
Clean the air filter.
Extend the recoil starter rope to check its condition. If
the rope is frayed, have it replaced immediately by an
authorized service center.
Remove all hoses. Coil the hoses and store as shown.
Do not allow the hose to become kinked.
Store the unit and accessories in an area that does not
reach freezing temperatures. Do not store near furnace or
other sources of heat that could dry out the pump seals.