19
TROUBLESHOOTING
Problem
Cause
Solution
Engine will not
start
Engine switch is set to
"off".
Set engine switch to "on".
Fuel valve is turned to
"closed".
Turn fuel valve to "open" position.
Choke is open.
Close the choke
Engine is out of gas.
Add gas.
Engine is filled with
contaminated or old gas.
Change the gas in the engine.
Spark plug is dirty.
Clean spark plug.
Spark plug is broken.
Replace spark plug.
Generator is not on level
surface.
Move generator to a level surface to prevent low oil shutdown
from triggering.
Oil is low.
Add or replace oil.
Engine runs but
there is no
electrical output
Circuit reset button is off.
Wait for 2 minutes and push the circuit reset button to the "on"
position.
Bad
connecting
wires/cables.
If you are using an extension cord, try a different one.
Bad
electrical device
connected to generator.
Try connecting a different device.
Generator runs but
does not support
all electrical
devices
connected.
Generator is overloaded
Perform these steps: 1. Turn off all electrical devices.
2. Unplug all electrical devices. 3. Turn off generator. 4. Wait
several minutes. 5. Restart generator. 6.Try connecting fewer
electrical loads to the generator.
Short in one of the
connected devices.
Try disconnecting any faulty or short-circuited electrical loads.
Air cleaner is dirty.
Clean or replace air cleaner.
Содержание 6500e
Страница 1: ...i OWNER S MANUAL ...
Страница 25: ...20 WIRING DIAGRAM with idle control system ...
Страница 26: ...21 WIRING DIAGRAM without idle control system ...