11
CAUTION- The generator can run at its surge wattage capacity for only a short time.
Connect electrical devices requiring a rated (running) wattage equal to or less than the rated
wattage of the generator. Never connect devices requiring a rated wattage equal to the surge
wattage of the generator.
tool or appliance
rated (running) Watts
additional surge Watts
electric water heater (40 gal)
4000
0
hot plate
2500
0
saw- radial arm
2000
2000
electric stove
1500
0
saw- circular
1500
1500
air compressor (1 HP)
1500
3000
window air conditioner
1200
1800
saw- miter
1200
1200
microwave
1000
0
well water pump
1000
1000
reciprocating saw
960
1040
sump pump
800
1200
refrigerator freezer
800
1200
furnace blower
800
1300
computer
800
0
electric drill
600
900
television
500
0
deep freezer
500
500
garage door opener
480
0
stereo
400
0
box fan
300
600
clock radio
300
0
security system
180
0
dvd player/ vcr
100
0
common light bulb
75
0
NOTE: The above wattage figures are estimates. Try to check the wattage listed on your electrical
device before consulting this chart.
Figure 8- Estimated wattage requirements of common electrical devices.
Once you have determined what electrical devices you will be powering with the generator, connect
these devices according to the following procedure:
1.
Plug in each electrical device with the device turned off.
NOTE:
Be sure to attach appliances
to the correct receptacle (outlet). Connect standard 120 Volt, single phase, 60 Hz loads
only
to
the 120 Volt receptacles. Connect 120/240 Volt, single phase, 60Hz loads with a NEMA L14-
30 plug
only
to the 120/240 Volt receptacle See Figure 9 for a depiction of each of these
receptacles.
2.
Check that the pilot light are lit under the engine switch.
CAUTION:
Do not connect 50Hz or 3-phase loads to the generator.