Radio Frequency InterferenceRequirements-FCC

Note: This equipment has been tested and found to comply with the limits for a  
Class B digital device, pursuant to Part 15 of the FCC rules. These limits are  desig
ned to provide reasonable protection against harmful interference in a  resident
ial installation. This equipment generates, uses and can radiate radio  frequency 
energy and, if not installed and used in accordance with the  instructions, may c
ause harmful interference to radio communications. However
there is no guarantee that interference will not occur in a particular installation. If this  
equipment does cause harmful interference to radio or television reception, which  
can be determined by turning the equipment off and on, the user is encouraged to  
try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment into an outlet on a circuit different from that to which  

the receiver is connected

Consult the dealer or an experienced radio/TV technician for help. 

Radio Transmitters (Part15)

This device complies with Part 15 of the FCC Rules. Operation is subject to the  follo
wing two conditions: (1) this device may not cause harmful interference, and (2)  this 
device must accept any interference received, including interference that may  cau
se undesired operation.

FCCRF Exposure Guidelines  
Safety Information
Reducing RF Exposure - Use Properly

Only operate the device in accordance with the instructions supplied.
This device complies with FCC radiation exposure limits set forth for an  uncontrol
led environment. In order to avoid the possibility of exceeding the FCC  radio freq
uency exposure limits, human proximity to the antenna shall not be less  than 20c
m (8 inches) during normal operation.
Changes or modifications not expressly approved by the party responsible for  
compliance could void the

user‘s

authority to operate the equipment.

Radio Frequency Interference Requirements-Canada

This Class B digital apparatus complies with Canadian ICES-003.  

Radio Transmitters

This device complies with RSS 210 of Industry & Science Canada. Operation is  su
bject to the following two conditions: (1) this device may not cause harmful  inte
rference and (2) this device must accept any interference received, including  int
erference that may cause undesired operation.
Label Marking: The Term

“IC:” 

before the radio certification only signifies that  

Industry Canada technical specifications were met.

Pro7 Touchscreen controls

The pro7 software is organized in four modules: Complete Programs, Express workouts,  
Single Exercises, ManualMode.

1. Home page

Complete Program:

Select your goal between Feel Better,  
Look Better or Play Better

Select a specific Program

Select your level and duration of the  
program between 10 and 30 min.

Express Workouts:

Select a mini program

Single Exercise:

Select an element between Stretch,  
Core, Balance, Strength and Massage

Select a specific exercise.

Manual Mode:

Select aduration

Select the G-Factor

I.1.1Education

This button takes you to the education
screen. It is broken downinto 5 educa-
tional videos
3 Goals
5elements  
G-Factor
New to Power Plate  
Welcome to the pro7

Appendix

FCC / IC statement

16 of 22

17 of 22

Содержание pro7

Страница 1: ...pro7 Model...

Страница 2: ...our body Over time the intensity and duration can be in creased in the same manner as other progressive training programs Once the body h as adapted to vibration the training can be changed or intensi...

Страница 3: ...andCardiovascular Claim Power Plate training can be a ben eficial tool intervention to improve and i ncrease circulation and improve the func tion of the cardiovascular system Definit ion The circulat...

Страница 4: ...e is not repairable and contains no user serviceableparts The user must check that the equipment functions safely and see that it is in proper working condition before being used The manufacturer does...

Страница 5: ...s should be used within the normal r ange and angle to maximize training ef fect and prevent damaging the device T he cables should be used between 90 degrees and 25degrees from the horizontal base Te...

Страница 6: ...re thatth eoutletisreceivingelectricalpower If the console display is illuminated but the platform will not vibrate unplug the machine wait at least one minute then check the connection to the machine...

Страница 7: ...meror the user of Pro7should assure that it isused in such an environment NOTE UTis the a c mains voltage prior to application of the test level Immunitytest IEC60601testlevel Compliancelevel Electrom...

Страница 8: ...establishments including domestic establishments and those directly con nected to the public low voltage pow er supply network that supplies buildi ngs used for domestic purposes Both models have bee...

Страница 9: ...rmalatmospheric conditions 860 1060hPa STORAGE AND SHIPPINGCONDITIONS Temperature 10 C to40 C Humidity 10 to 95 RH Pressure altitude Normalatmospheric conditions 860 1060hPa WARNING The device is not...

Страница 10: ...h the instructions supplied This device complies with FCC radiation exposure limits set forth for an uncontrol led environment In order to avoid the possibility of exceeding the FCC radio freq uency e...

Страница 11: ...t directly influence the intensity feltby the user but the duration of the exercis e Intensity level The intensity on the machine can be determined by multiplying frequency and a mplitude The platform...

Отзывы: