background image

 

ii 

The unit must be installed on a sturdy level surface and ensure there is 
adequate ventilation (at least 10cm all round). Do not put objects on top 
of the unit. Do not situate the unit on a rug or other soft surface or 

obstruct any air inlets or outlets. Do not install the unit near any heat 

sources such as radiators, stoves or other apparatus that produce heat. 
Do not locate the unit in an enclosed area such as a bookcase or in a 
cabinet with insufficient ventilation. Do not stack multiple units on top of 
each other.  

 
The unit is not user serviceable and no attempts should be made to repair 

or disassemble it in the event of a fault. Servicing is required if the unit 
becomes damaged in any way, such as the power supply cord or plug 
being damaged, liquid been spilt or objects have fallen into it, if the unit 
has been exposed to rain or moisture, has been dropped or does not 

operate normally.   

 

 
 
This product complies with the European Low Voltage 

(2006/95/EC) and Electromagnetic Compatibility 

(2004/108/EC) Directives when installed and used in 
accordance with this instruction manual. 
 
 

 
The crossed-out wheeled bin is the European Union symbol 

for indicating separate collection for electrical and electronic 
equipment. This product contains electrical and electronic 
equipment that should be reused, recycled or recovered and 
so should not be disposed of with unsorted regular waste. 

Please return the unit or contact your authorised dealer from 

where the product was purchased for more information. 
 
 
Plug Fitting Instructions (U.K.) 

 
The power cord supplied with this product is factory fitted with a 13amp 

mains plug fitted with a 4.0 amp slo-blo fuse. If it is necessary to change 
the fuse it is important that a 4.0 amp slo-blo replacement fuse is used. If 
the plug needs to be changed because it is not suitable for your socket, or 

becomes damaged, it should be cut off and an appropriate plug fitted 
following the wiring instructions below. The unused plug should be 

disposed of safely as insertion into a 13amp socket is likely to cause an 
electrical hazard. Should it be necessary to fit a 3 pin BS mains plug to 
the power cord the wires should be connected as detailed below. The 

colours of the wires in the mains lead of this product may not correspond 
with the coloured markings identifying the terminals in your plug. Connect 
them as follows: 

 
The wire which is coloured BLUE must be connected to the terminal which 
is marked with the letter ‘N’ or coloured BLACK. 

 

Содержание Belles 350A Reference

Страница 1: ...ReferencePower Amplifier Instruction Manual ...

Страница 2: ...ion grills If this occurs switch off immediately disconnect from the mains supply and contact your dealer for advice Safety Precautions Check that the rear of the unit indicates the correct mains supply voltage and frequency If your mains supply voltage or frequency is different please consult your dealer The unit is designed to operate only on the supply voltage and type that is indicated on the ...

Страница 3: ...nion symbol for indicating separate collection for electrical and electronic equipment This product contains electrical and electronic equipment that should be reused recycled or recovered and so should not be disposed of with unsorted regular waste Please return the unit or contact your authorised dealer from where the product was purchased for more information Plug Fitting Instructions U K The p...

Страница 4: ...ch is coloured GREEN YELLOW must be connected to the terminal which is marked with the letter E or coloured GREEN If a 13amp BS1363 plug is used a 4 0 amp slo blo fuse must be fitted or if any other type of plug is used a 4 0 amp slo blo or 4 0 amp slo blo fuse must be fitted either in the plug or adapter or on the distribution board ...

Страница 5: ...per care the appearance of the Belles 350A Reference will be preserved for years Unpacking the Unit When you receive your unit carefully inspect the carton for any damage Any obvious dents or scuff marks should alert you to the possibility of damage to the contents If any external damage to the carton is found note the location in relation to the orientation of the amplifier as it is removed from ...

Страница 6: ...ugging in or unplugging interconnect cables running from the source to the pream plifier or sound processor always make sure that the preamplifier or sound processor vol ume control is set at zero 1 Before doing anything be sure that the power switch on the amplifier s front panel is in the off position Please do not turn the amplifier on until directed to do so 2 Locate the A C power supply cord ...

Страница 7: ... post 6 Connect the right speaker cable positive red wire terminal to the right monoblock right red speaker binding post 7 Connect the right speaker cable negative black wire terminal to the right monoblock left red speaker binding post There should be no connections to either black binding post 8 Connect the power cords to each amplifier 9 Power on the system using the following order sources suc...

Страница 8: ...hannel into 8 ohms Distortion THD and IM less than 0 1 at rated power Damping Factor over 2000 Peak Current 64 amperes Stereo Inputs Unbalanced stereo only Monoblock Inputs Balanced only Input Sensitivity 1 98 for rated power Input Impedance 50 000 ohms Hum Noise over 100 dB Crosstalk over 60 dB Frequency Response 0 2 to 100 000 Hz Dimensions 17 W x 5 25 H x 16 5 D Shipping Weight 65 pounds Power ...

Страница 9: ... and the manufacturer neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the sale of this product This warranty is not transferable except by written authorization from the manufacturer In order to qualify under the terms of the above warranty all items must be returned to the appropriate factory service depot with all shipping charges p...

Отзывы: