The Power Hawk
®
P-16 Rescue System Instruction Manual
Page 25 of 34
2019-09
NOTE
The 70
-rotation limits of the P-16 powerhead is
maintained through the use of a stop screw. To
protect the tool from serious damage, the stop
screw is designed to shear should the tool body
become jammed against other objects and loaded
during operation with no more rotational freedom
of the powerhead. If this happens, the tool, though
still operational, has lost its safety stop positioning
and must be repaired by replacing the stop screw
(See Maintenance section). This condition will be
apparent since the P-16 attachments will be
capable of swinging beyond 70
and making
contact with the carrying handle when the clutch is
loose.
WARNING
Do not load the P-16 Rescue Tool such that the body becomes jammed against other
objects and is loaded. Shearing of the stop screw causes loss of the 70
safety stops.
Operating the tool in this condition may result in serious personal injury and/or damage
to property and/or equipment.
Stop