The Power Hawk
®
P-16 Rescue System Instruction Manual
Page 9 of 34
2019-09
PWR-12MP Power Pack, 12V Lead Acid AGM
The PWR-12MP Power Pack is a vented portable battery pack that utilizes a 33 amp-
hour valve-regulated lead-acid battery (VRLA). The PWR-12MP Power Pack comes
equipped with two red “Power Output” plugs which can provide power to two devices
simultaneously, including the PC-100 Controller Unit for P-16 Rescue Tool operation
or other accessories such as the portable winch, Sawzall, circular saw, impact
wrench, ventilator fan, air bag compressor, and more. A charge indicator and test
button are provided so that the user can visually check the charge state of the
internal battery. The PWR-12MP Power Pack includes a battery charger port for
connection to the required battery charger (i.e. Model BC-U1) provided by POWER
HAWK Technologies, Inc. (See Battery Charger Operation section of this manual.)
WARNING
Do not make direct contact between battery positive and
negative terminals as this can cause an explosion or fire.
Keep the protective caps snapped in place over the 2 red
connector terminals and charger port when not in use.
The Power Hawk
®
PWR-12MP Power Pack is vented to allow any
hydrogen gas exhausted by the internal battery to safely diffuse out of
the carrying case without dangerous build-ups. These vents and drain
holes are shown below (holes on the front cover, strap slots in the
back, holes on the top, and a drain hole on the bottom).
CAUTION
Prior to charging, inspect case to ensure all vent and drain holes are clear and fully
open. Do not plug holes. Inspect vents and drain holes after each use.
Prior to selecting the PWR-12MP Power Pack, note the charge condition of the
battery by depressing the test button located on the side of the unit. A fully
charged battery is indicated by the position of the dial in the green above the
“recharge line”. As the charge on the battery is depleted, the indicator dial will
move toward the yellow and red bars, indicating reduced battery capacity.
IMPORTANT
: The battery gauge will show the proper voltage level ONLY
when the battery is in its “settled” state. It will not indicate accurate state-of-
charge under the following conditions:
1.
During recharging
, the battery gauge will show above the recharge line, even if the battery is not
yet fully charged. After disconnecting the charger from the battery pack, it may take up to 20 minutes for
the battery to “settle” and for the gauge to indicate the actual charge level. If the battery is being
recharged, you MUST use the charger indicator lights to determine if the battery has reached its fully
charged condition (see Battery Charger Operation section).
Front View
Back View
Top View
Bottom View
Protective
Caps
!
!