SS2L / SS2R Series
www.powergenex.com
20
7.2 Mounting onto Rotary Actuator
7.2.1 The SS2R positioner supports NAMUR mounting standard (VDI/VDE 3835, IEC 60534-6-2).
①
SS2R positioner
②
Multi-size bracket
③
Rotary pneumatic actuator
ⓐ Assemble the multi-size bracket to the SS2R positioner with 4 pcs M6 screw. The multi-size
bracket is assembled for 80x30x20mm as standard at the factory. If you have other size bracket,
see ‘7.2.4 Re-assembling Multi-size Bracket according to Rotary Actuator’.
ⓑ Mount the SS2R positioner onto the rotary pneumatic actuator with 4 pcs M5 screw.
ⓒ Connect air lines between the SS2R positioner and the rotary pneumatic actuator.
ⓓ Perform auto-calibration by pushing MODE button for 5 seconds.
Make sure that the SS2R positioner works within the operating range indicated on the
bottom. See the below pictures. Otherwise, the error message of ‘MONT’ appears on
LCD and the auto-calibration process fails.
<Maximum operating angle : 100°>
<Indicator position at 50%>