Before installation, read the following 
instructions carefully. Failure to follow 
instruction and Safety information could 
cause serious bodily injury, death and/or 
property damage. Each Power-Flo pump is 
individually factory tested to insure proper 
performance. Closely following these 
instructions will eliminate potential operating 
problems, assuring years of trouble-free 
service.

IMPORTANT - Power-Flo Pumps and 

Systems is not responsible for losses, injury 

or death resulting from failure to observe 
these safety precautions, misuse, abuse or 
misapplication of pumps or equipment.

 

 Do not pump 

  flammable or explosive 

  liquids such as oil,  

  gasoline, kerosene, 

  ethanol, etc. Do not 

  use in the presence 

of  flammable or explosive vapors. Using 

this pump with or near flammable liquids 

can cause an explosion or fire, resulting in 

property damage, serious personal injury, 

and/or death.

  

ALWAYS

 disconnect

  the power to the pump 

before servicing.

 Release all pressure and
 drain all water from the 

system before servicing any component.

  Do not touch the 
  motor housing during 

  operation. The motor is designed 
  to operate at high temperatures. 
  Do not disassemble the motor 
  housing.

  Do not handle the 

  pump or pump motor 

  with wet hands or when standing 
  on a wet or damp surface, or in 
  water before disconnect the power.

  Secure the discharge 
  line before starting the 

pump. An unsecured discharge line will whip, 
possibly causing personal injury, and/or 
property damage.

  Extension cords may 
  not deliver sufficient 

  voltage to the pump motor. 
  Extension cords present a life 
  threatening safety hazard if 

the insulation becomes damaged or the 
connection ends fall into water. The use of 
an extension cord to power this pump is not 
permitted.

  Wear safety goggles at 

  all times  when 

working with pumps.

  

These units are designed 

  for use on 115 volts or 

230 volts (single phase), 60 Hz, and equipped 

with an approved 3-conductor cord and 

3-prong grounded plug. Do not remove the 

ground pin under any circumstances. The 

3-prong plug must be directly inserted into 

a properly installed and grounded 3-prong, 

grounding-type receptacle. Do not use this 

pump with a 2-prong wall outlet. Replace 

the 2-prong outlet with a properly grounded 

3-prong receptacle (a GFCI outlet) installed 

in accordance with the National Electrical 

Code and local codes and ordinances. All 

wiring should be performed by a qualified 
electrician.

 

 

 

  Protect the electrical
  cord from sharp 

objects, hot surfaces, oil, and chemicals. Avoid 

kinking the cord. Do not use damaged or 

worn cords.

  Failure to comply with 
  the instruction and 

designed operation of this unit may void the 

warranty. 

ATTEMPTING TO USE A DAMAGED 

PUMP

 can result in property damage, serious 

personal injury, and/or death.

  Ensure that the 
  electrical circuit to 

the pump is protected by a 20 Amp - for 115V 
or 10 Amp for 230V,  fuse or circuit breaker.

   Do not lift the pump 

 

  by the power cord.

  Know the pump and its 

 

 applications, 

limitations, and potential hazards.

IMPORTANT !

 - Secure the pump to a solid 

base. This will aid in keeping the pump in a 

vertical orientation. This is critical in keeping 

the pump operating at maximum efficiency. 

It will also help prevent the pump from 

clogging resulting in premature failure.

IMPORTANT !

 - Periodically inspect the pump 

and system components to ensure the pump 

suction screen is free of mud, sand, and 

debris. Disconnect the pump from the power 

supply before inspecting.

  Follow all local 
  electrical and safety

codes, along with the National Electrical Code 
(NEC). In addition, all Occupational Safety 
and Health Administration (OSHA) guidelines 
must be followed.

  The motor of this pump
  has a thermal protector 

that will trip if the motor becomes too hot. 

The protector will reset itself once the motor 

cools down and an acceptable temperature 

has been reached. The pump may start 

unexpectedly if it is plugged in.

  Ensure the electrical 

  

power source is 

adequate for the requirements of the pump.

IMPORTANT ! 

- This pump is made of high-

strength, corrosion-resistant materials. It will 
provide trouble-free service for a long time 
when properly installed, maintained, and used. 
However, inadequate electrical power to the 
pump, dirt, or debris may cause the pump to 

fail

Содержание PFSWCPC75

Страница 1: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com ISP No PFSWC75 8 1 15 OWNER S MANUAL Series PFSWCPC75 3 4 HP 1750 RPM 60 Hz Submersible Sewage Pump...

Страница 2: ...approved 3 conductor cord and 3 prong grounded plug Do not remove the ground pin under any circumstances The 3 prong plug must be directly inserted into a properly installed and grounded 3 prong grou...

Страница 3: ...tic 115V SJTW 16AWG 3C 230V SJTW 18AWG 3C 10 Ft cord with Piggy back plug On Off points are adjusteable Attaches to discharge piping WARRANTY 3 year MODEL HP Hz Volts Ph RPM FL AMPS Cord Length Wt PFS...

Страница 4: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 4 Performance Dimensions PFSWCPC75Series Submersible Sewage Pumps Models PFSWCPC75201451F10 PFSWCPC75201452F10...

Страница 5: ...ethered Mechanical Normally Open N O Reinforced thermoplastic 115V SJOW 16AWG 2C 230V SJOW 18AWG 2C 10 Ft cord w Piggy back plug On point 16 5 Off point 8 7 WARRANTY 3 year MODEL HP Hz Volts Ph RPM FL...

Страница 6: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 6 PFSWCPC75Series Submersible Sewage Pumps Performance Dimensions Models PFSWCPC75201451T10 PFSWCPC75201452T10...

Страница 7: ...inch solids The pump is built with overload thermal protections and auto reset The pump is equipped with a 3 prong grounding type power cord and tethered or vertical float switch This pump operates a...

Страница 8: ...ord plug to be submerged Step 3 DO NOT use extension cords They are a fire hazard and can reduce voltage sufficiently to prevent pumping and or damage motor Step 4 DO NOT handle or service pump while...

Страница 9: ...will void the warranty and may damage the pump An automatic overload protector in the motor will protect motor from burning out due to overheating overloading When motor cools down overload protector...

Страница 10: ...pump and control switch Submerge pump in a disinfectant solution bleach for at least one hour before disassembling pump Put the pump upside down Note Pump is oil filled to void the oil leakage don t...

Страница 11: ...Reposition the pump and make sure switch moves freely Pump operates but pumps little or no water 1 Debris caught in impeller or pipe 2 Check valve stuck or installed backward 3 Anti airlock hole bloc...

Страница 12: ...tances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances washtowelsorfemini...

Отзывы: