Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
10
PFSWCPC75 Series
Submersible Sewage Pumps
General
WARNING: Risk of electric shock. Can shock, burn or kill.
• Do not lift pump by power cord.
Before removing pump from basin for service, always disconnect electrical power to pump and control switch.
•
Submerge pump in a disinfectant solution (bleach) for at least one hour before disassembling pump.
•
Put the pump upside down.
•
Note:
Pump is oil filled, to void the oil leakage don’t incline the pump.
Unscrew the stainless screws, and remove the volute/gasket.
•
Use a flathead screwdriver to hold the shaft, then turn the impeller counterclockwise to release the impeller.
•
Remove debris from around the shaft and on/under the impeller.
•
Reassemble the pump.
•