By adjusting the cord tether the control 
level can be changed. 

DO NOT USE THE 

POWER CABLE TO LIFT PUMP. 

Thermal Protection:

The normally closed (N/C) over 
temperature sensor is embedded in the 
motor windings and will detect excessive 
heat in the event an overload condition 
occurs. 

The thermal sensor will trip when the 
windings become too hot and will 
automatically reset when the pump 
motor cools to a safe temperature. 
It is recommended that the thermal 
sensor be connected in series to an alarm 
device to alert that an overtemperature 
condition and/or motor starter coil to 
stop pump.

In the event of an overtemperature, 
the source of this condition should be 
determined and repaired immediately. 
Thermal protection shall not be used as a 
motor overload device.

Pre-Operation

1.   Check Voltage and Phase
 

Compare the voltage and phase

 

information stamped on the pump 

 name 

plate.

2.    Plug cord into an 200 or 230 volt 
 

receptacle with ground fault circuit 

 interrupter 

(GFCI)

3.

 

Check Pump Rotation

 - Improper 

 

motor rotation can result in poor 

 

pump performance and can damage

 

the motor and/or pump. Check 

 

rotation by momentarily applying 

 

power and observe the “kickback”.  

 

Kickback should always be in a 

 

counter-clockwise direction as 

 

viewed from motor end or opposite 

 

to impeller rotation. Incorrect rotation 

 

for Single-Phase pumps is unlikely. 

 

If the rotation is incorrect contact 

 factory.

4.   

Name Plate

 - Record the information

 

from the pump name plate to 

 

drawing in front of manual for future 

 reference.

5.  

Pump-Down Test

 - Be sure pump 

 

has been plugged in, lowered into 

 

the basin or sump, check the system 

 

by filling with liquid and allowing the

 

 pump to operate through its 

 

pumping cycle. The time needed to

 

empty the system, or pump-down 

 

time along with the volume of water, 

 

should be recorded.

Maintenance

No lubrication or maintenance is required. 
Perform the following checks when  pump 
is removed from operation or when pump 
performance deteriorates:
a).   Inspect motor chambers for oil level 
 and 

contamination.

b).  Inspect impeller and body for 
 

excessive build-up or clogging.

c).  Inspect motor and bearings.
d).  Inspect seal for wear or leakage.

Servicing

NOTE: Item numbers in ( ) refer to Figures 
10 & 11.

Cooling Oil - 

Anytime the pump is 

removed from operation, the cooling oil 
in the motor housing should be checked 
visually for oil level and contamination.

To check oil, set unit upright. Loosen 
gland nut (3), remove cap screws (22) and 
lockwashers (11) from upper housing 
(19) and carfully slide up the power cable 
and lay off  to the side. Remove pipe plug 
(4) from housing (15).  With a flashlight, 
visually inspect the oil in the housing (15) 
to make sure it is clean and clear, light 
amber in color and free from suspended 
particles. 

Milky white oil indicates the presence of 
water. Oil level should be just above the 
motor when pump is in vertical position.

Oil Testing

•  Drain oil into a clean, dry container by
  placing pump on it’s side. Remove  
  upper housing (19) then remove pipe 
  plug (4), from housing (15). 
•  Check oil for contamination using an 
  oil tester with a range to 30 Kilovolts 
 breakdown.
•  If oil is found to be clean and 
  uncontaminated (measuring above 
  15 KV. breakdown), refill the housing.
•  If oil is found to be dirty or 
  contaminated (or measures below 
  15 KV. breakdown), the pump must 
  be carefully inspected for leaks at the 
  shaft seal, cable assembly, square ring 
  and pipe plug, before refilling with oil. 
  To locate the leak, perform these
 pressure 

tests.

After leak is repaired, dispose of old oil 
properly, and refill with new oil.

Upper Housing Pressure Test:

See Figure 3. Remove pipe plug (4) from 
housing (19).  Apply pipe sealant to 
pressure gauge assembly and tighten 
into hole. Pressurize upper motor 
housing to 10 P.S.I.  Use soap solution 
around the sealed area above the oil 
level and inspect for “air bubbles” around 
the joint between the upper housing 
(19) and lower housing (15). Also check 
around gland nut and power cable. If, 
after five minutes, the pressure is still 
holding constant, and no “bubbles” /
oil seepage is observed, slowly bleed 
the pressure and remove the gauge 
assembly. If no leak has been found, 
continue to the Lower housing Test.

Installation & Service

PFGPC - 2HP 

 

 

  

              

     

    Submersible Grinder Pumps

BACK TO INDEX

Содержание PFGPC2002HH Series

Страница 1: ...TALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFGPC2002HVS HHS PFGPC2002HVSA HHSA PFGPC2022HVS HHS PFGPC2022HVSA HHSA Single Seal 2 HP 3450 RPM 60 Hz...

Страница 2: ...toys utensils etc Sanitary Napkins or Tampons Diapers Rags Disposable Wipes or Cloth Medications Flammable Material Oil or Grease Strong Chemicals Gasoline Risk of electric shock To reduce risk of el...

Страница 3: ...Steel CUTTER Stainless Steel SHAFT Stainless Steel SQUARE RINGS Buna N HARDWARE Stainless Steel PAINT Powder Coated Industrial Grade SEAL Single Mechanical Carbon Ceramic Buna N UPPER BEARING Single r...

Страница 4: ...3450 17 0 53 0 F SOW 12 3 67 PFGPC2022HHSA 2 60 230 1 3450 15 0 53 8 H SOW 12 3 67 Specifications Dimensions MODEL HP Volts Ph BREAKER SIZE VOLTAGE RELAY START CAPACITOR RUN CAPACITOR High Volume PFG...

Страница 5: ...12 Vane Vortex Bronze SHREDDING RING Stainless Steel CUTTER Stainless Steel SHAFT Stainless Steel SQUARE RINGS Buna N HARDWARE Stainless Steel PAINT Powder Coated Industrial Grade POWER CORD 20 ft Cus...

Страница 6: ...ns Dimensions MODEL HP Volts Ph BREAKER SIZE VOLTAGE RELAY START CAPACITOR RUN CAPACITOR High Volume PFGPC2002HV 2 200 1 30 Amp internal MARS 169 internal 150 mfd 250v internal 20 mfd 450v PFGPC2022HV...

Страница 7: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 7 Performance PFGPC HH HHS 2HP Submersible Grinder Pumps BACK TO INDEX...

Страница 8: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 8 Performance PFGPC HV HVS 2HP Submersible Grinder Pumps BACK TO INDEX...

Страница 9: ...Discharge piping should be as short as possible and sized no smaller than the pump discharge Do not reduce the discharge pipe size below that which is provided on the pump Both a check valve and a shu...

Страница 10: ...chambers for oil level and contamination b Inspect impeller and body for excessive build up or clogging c Inspect motor and bearings d Inspect seal for wear or leakage Servicing NOTE Item numbers in...

Страница 11: ...te for oil expansion Apply pipe thread compound to threads of pipe plug 4 then assemble to motor housing 15 Check that o ring 24 is in place and does not need to be replaced Reassemble upper housing t...

Страница 12: ...k rotor for wear If rotor or the stator windings are defective the complete motor must be replaced Inner Seal Double Remove seal 53 rotating member and spring from rotor shaft Press stationary from in...

Страница 13: ...ith lockwashers 11 into seal plate and torque to 6 5 ft lbs Outer Seal Single Double Clean and oil stationary seal cavity in bearing bracket 21A on Single Seal or 51 seal plate on Double Seal Slide se...

Страница 14: ...e on threads and place into shaft and tighten Upper Housing Capacitors Assemble capacitors 14 16 and relay 13 to housing Place o ring 24 onto motor housing 15 Assemble gland nut 3 friction ring 46 and...

Страница 15: ...lopumps com 15 Figure 10 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFGPC HVS HHS 2HP Singl...

Страница 16: ...flopumps com 16 Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List PFGPC HV HH 2HP Double Seal Subm...

Страница 17: ...4 200 Volt 1 Ph PF081200S10 Motor Double Seal 230 volt 1 Ph PF110397BG 200 volt 1 Ph PF081200S06 18 1 6 Lower Bearing PF10 36 E4 19 1 Upper Housing PF105196CAP 20 1 6 Square Ring PF074498 21A 1 Bearin...

Страница 18: ...r Clamp 7mm PF033459 46 2 Friction ring PF051450 47 1 Bronze Insert Double Seal Only 48 1 Pipe Plug 1 4 NPT Double Seal Only 49 4 Stud 5 16 18 x 2 1 4 Lg Stainless Double Seal Only 50 4 Hex Nut 5 16 1...

Страница 19: ...equired Consult the factory Disconnect unit electrically Remove the pump from the basin Detach the pump base and clean the area around the impeller Rotate impeller by hand Reassemble and reinstall Pum...

Страница 20: ...ained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydroca...

Отзывы: