8843773
5/16 in. Straight Grip Air Punch and Flange Tool
V1.0
8
For technical questions call 1-800-665-8685
IDENTIFICATION KEY
A Punch die
B Punch
C Oil plug
D Trigger
E Clamp
F Anvil
G Air punch and flange tool
H Air Tool
ASSEMBLY & INSTALLATION
Letter references in parenthesis (A) refer to the included Identification Key.
INSTALL AIR COUPLER PLUG
Prepare a standard 1/4 in. NPT coupler plug (sold separately) for use with
your tool.
1.
Wrap the external threads of the coupler plug with sealant tape.
a.
Wrap tape in a clockwise direction so it will not unravel.
b. Do not tape all the threads. Leave several leading threads
unwrapped for easier alignment.
2. Screw the coupler plug into the tool's air inlet and tighten with a
wrench until snug.
3.
Run the compressor at a low volume and check the connection for air
leaks. Do not use the tool until all air leaks are repaired or the faulty
component is replaced.
IMPORTANT! Vibration may cause failure if a quick coupler is connected directly
to the air tool. To overcome this, connect a leader hose to the tool. A quick
coupler may then be used to connect the leader hose to the air line hose.
OPERATION
1.
Set the working pressure at 90 PSI / 6.3 BAR (see Specifications).
2. When finished with the tool, turn off the air compressor, disconnect
the air hose and discharge any residual air remaining in the tool. Put
the impact wrench away in a safe storage area.