background image

8843468 

3/8 in. Butterfly Air Impact Wrench 

V1.0 

10 

For technical questions call 1-800-665-8685 

CARE & MAINTENANCE 

1. 

Maintain the tool with care. A tool in good condition is efficient, easier 
to control and will have fewer problems. 

2. 

Inspect the tool fittings, alignment and hoses periodically. Have damaged 
or worn components repaired or replaced by an authorized technician. 
Only use identical replacement parts when servicing. 

3. 

Follow instructions for lubricating and changing accessories. 

4. 

Only use accessories intended for use with this tool.  

5. 

Keep the tool clean, dry and free from oil/grease at all times.  

6. 

Maintain the tool’s labels and name plates. These carry important 
information. If unreadable or missing, contact Princess Auto Ltd. for 
replacements. 

WARNING! Only qualified service personnel should repair the tool. An 
improperly repaired tool may present a hazard to the user and/or others. 

AIR TOOL LUBRICATION

 

NOTICE! Only use air tool oil to lubricate the tool. Other lubricants are not 
suitable and will damage the tool or cause a malfunction during use. 
NOTICE! Never use a penetrating oil to lubricate an air tool. Penetrating oil 
acts as a solvent that will dissolve the tool’s grease packing and may 
damage the o-rings, causing the tool to seize or malfunction. 

1. 

All air tools have an internal coating of grease to prevent corrosion 
during shipping and storage. Remove this grease by adding a generous 
amount of air tool oil in the air inlet and then run the tool under no 
load until the exhaust is clear. 

2.  Manually add a drop or two of air tool oil into the tool’s coupler plug 

before each use and after every hour of continuous use. The tool will 
not work properly without lubrication and parts will wear prematurely. 

3. 

Avoid adding too much air tool oil as this can cause premature power 
loss and eventual tool failure. A qualified technician will need to take 
the tool apart and clean out the excess oil.  

4. 

Apply a generous amount of air tool oil to the tool before storing it for 
an extended period of time (overnight, weekend, etc.). Run the tool for 
approximately 30 seconds to ensure the oil is evenly distributed 
throughout the tool. Store it in a clean and dry location.

 

Содержание 8843468

Страница 1: ...V1 0 8843468 Please read and understand all instructions before use Retain this manual for future reference...

Страница 2: ...property damage injury or death if certain instructions are not followed DANGER This notice indicates an immediate and specific hazard that will result in severe personal injury or death if the proper...

Страница 3: ...ce lights so you are not working in a shadow 2 Keep anyone not wearing the appropriate safety equipment away from the work area 3 Store unused tools properly in a safe and dry location to prevent rust...

Страница 4: ...ool Keep long hair covered or bound 3 Do not overreach when operating a tool Proper footing and balance enables better control in unexpected situations 4 Keep your fingers away from the trigger switch...

Страница 5: ...ot cover the air vents 6 Only use accessories that are specifically designed for use with the tool Ensure the accessory is tightly installed 7 Only use an accessory that exceeds the speed rating see S...

Страница 6: ...be regulated to never exceed the maximum pressure rating of the tool see Specifications Exceeding the maximum PSI rating can create a bursting hazard causing injury and property damage 5 Attach all ac...

Страница 7: ...hang on a hook or fasten with a device to keep hose together when storing 4 A damaged or disconnected air hose under pressure may whip around and inflict personal injury or damage the work area Secure...

Страница 8: ...he included Identification Key INSTALL AIR COUPLER PLUG Prepare a standard 1 4 in NPT coupler plug sold separately for use with your tool 1 Wrap the external threads of the coupler plug with sealant t...

Страница 9: ...strip the workpiece and damage the tool potentially causing tool failure and serious injury Use other appropriate methods and tools to tighten the nut 6 This tool will stop operation rotation a few se...

Страница 10: ...t suitable and will damage the tool or cause a malfunction during use NOTICE Never use a penetrating oil to lubricate an air tool Penetrating oil acts as a solvent that will dissolve the tool s grease...

Страница 11: ...ian service the tool 2 Replace tool or parts Tool runs slowly Air flows slightly from exhaust Motor parts jammed with dirt particles OR Airflow blocked by dirt 1 Check air inlet filter for blockage 2...

Страница 12: ...mechanism and lubricate Loss of power or erratic performance 1 Excessive drain on the air hose Incorrect size or type of hose connectors 2 Moisture or restriction in the air hose tank 3 Air compressor...

Страница 13: ...gger Switch 1 4 Anvil Bushing 1 5 Socket Retainer Ring 1 6 O Ring 1 7 Anvil 1 8 Hammer Pin 1 9 Hammer Cage 1 10 Hammer Dog 1 11 Drive Cam 1 12 Oil Seal 1 13 Ball Bearing 2 14 Front End Plate 1 15 Roto...

Страница 14: ...al questions call 1 800 665 8685 28 O Ring 2 29 O Ring 1 30 Air Inlet Block 1 31 Spring 1 32 Steel Ball 1 33 Air Regulator 1 34 Throttle Pin 2 35 Washer 1 36 Retainer Ring 1 37 Spring Washer 4 38 Cap...

Страница 15: ...V1 0 3 8 in Butterfly Air Impact Wrench 8843468 Visit www princessauto com for more information 15...

Страница 16: ...8843468 3 8 in Butterfly Air Impact Wrench V1 0 16 For technical questions call 1 800 665 8685...

Страница 17: ...V1 0 8843468 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard...

Страница 18: ...age la propri t de blessure ou de d c s si on ne respecte pas certaines instructions DANGER Cet avis indique un risque imm diat et particulier qui entra nera des blessures corporelles graves ou m me l...

Страница 19: ...e travail propre bien clair e et exempte de toute distraction Placez les lampes de fa on ne pas travailler dans l ombre 2 Assurez vous que les personnes qui ne portent pas l quipement de s curit appro...

Страница 20: ...rogues d alcool ou de m dicaments 2 vitez de porter des v tements ou des bijoux pouvant se prendre dans les pi ces mobiles d un outil Gardez les cheveux longs recouverts ou attach s 3 N utilisez pas l...

Страница 21: ...i ces pr sentent des dommages ou sont d plac es R parez ou remplacez les pi ces 3 N utilisez pas d outil lectrique muni d un interrupteur d alimentation ou d une commande qui fait d faut Un outil lect...

Страница 22: ...s l avoir utilis e Elles peuvent tre chaudes et causer une br lure 14 Ne d posez pas l outil jusqu ce que l accessoire ait compl tement cess de tourner L accessoire peut toucher la surface de la pi ce...

Страница 23: ...mez la source d air comprim et purgez l outil d air de tout air comprim restant avant de laisser celui ci sans surveillance 9 Des blessures graves peuvent se produire si des d bris sont propuls s haut...

Страница 24: ...d air du compresseur une structure fixe ou permanente au moyen de serre c bles ou d attache c bles 5 Si vous utilisez un tuyau air dont la longueur exc de 25 pi augmentez l al sage du tuyau en s lect...

Страница 25: ...rotation sens horaire antihoraire D R gulateur pneumatique E Entr e d air ASSEMBLAGE ET INSTALLATION Les lettres de r f rence entre parenth ses A se rapportent la cl d identification comprise POSE DU...

Страница 26: ...male 5 Placez la douille sur la fixation saisissez fermement la cl chocs deux mains et pressez doucement l interrupteur bascule de rotation sens horaire antihoraire C 5 1 Pressez sur le c t droit de l...

Страница 27: ...ile contr ler et pr viendra les probl mes de fonctionnement 2 Inspectez les fixations de l appareil l alignement and les tuyaux p riodiquement Demandez un technicien autoris de r parer ou de remplacer...

Страница 28: ...s useront pr matur ment 3 vitez d ajouter une trop grande quantit d huile pour outil pneumatique puisque cela peut entra ner une perte de puissance pr matur e et ventuellement un bris de l outil Un te...

Страница 29: ...3 Actionnez l outil en pulsions courtes pour enlever les d bris 4 Si l outil est toujours bouch nettoyez le et lubrifiez le de la fa on d crite dans les instructions de lubrification L outil fonction...

Страница 30: ...Humidit ou obstruction dans la conduite d air le r servoir 3 Le d bit du compresseur d air est insuffisant 1 V rifiez la conduite d air et confirmez que le raccord de tuyau convient parfaitement la d...

Страница 31: ...re 1 4 Bague d enclume 1 5 Anneau de retenue de la douille 1 6 Joint torique 1 7 Enclume 1 8 Goupille de marteau 1 9 Cage de marteau 1 10 Bague de marteau 1 11 Came 1 12 Joint d huile 1 13 Roulement b...

Страница 32: ...6 Ressort 2 27 Piston plongeur 2 28 Joint torique 2 29 Joint torique 1 30 Bloc d entr e d air 1 31 Ressort 1 32 Bille en acier 1 33 R gulateur pneumatique 1 34 Pivot de l interrupteur bascule 2 35 Ron...

Отзывы: