Power Fist 8513541 Скачать руководство пользователя страница 7

1/2 HP Totally Enclosed Fan Cooled Electric Motor

7

Visit www.princessauto.com for more information

8513541

V 3.03

WIRING YOUR MOTOR

WARNING! Do not touch electrical connections unless  

you first ensure that power has been disconnected.  

Please refer to: OSHA standard 1910.147 titled: The 

Control of Hazardous energy (lockout/tag-out).
WARNING! Surface temperatures of motor enclosures 

may reach temperatures that can cause discomfort or 

injury to personnel coming in contact with hot surfaces. 

Protection should be provided by the user to protect 

against accidental contact with hot surfaces. Failure to 

observe this precaution could result in bodily injury.

Connect the motor as shown in the connection diagram 

on the motor nameplate. Be sure to identify the proper 

wiring diagram for the motor you are installing. If you have 

difficulty determining the proper wiring diagram for your 

motor, please contact Princess Auto for assistance.
If this motor is installed as part of a motor control drive 

system, connect and protect the motor according to the 

control manufacturer’s diagram. When using AC motors 

with frequency inverters, be certain that the motors 

maximum speed rating is not exceeded.  

The wiring, fusing and grounding must comply with the 

Canadian Electrical Code (CE) or International  

Electrotechnical Commission (IEC) and local codes.
If improper rotation direction is detrimental to the load, 

check the rotation or ‘bump’ the motor prior to coupling the 

load to the motor shaft. When the motor is coupled to the 

load and started, it should start quickly and run smoothly. If 

not, stop the motor immediately and determine the cause. Possible causes are: low voltage at the motor, 

motor connections are not correct or the load is too heavy. Check the motor current after a few minutes of 

operation and compare the measured current with the nameplate rating.

THERMAL OVERLOAD PROTECTION

An internal thermal protector disconnects the electrical contacts when the motor draws too much current 

and overheats, forcing it to shut down before it is damaged. 

1.  Switch the power source off and let the motor cool before attempting a reset. 

2.  Reduce the load on the motor to prevent the thermal protector from tripping again.

3.  Push the thermal reset button hard until a sharp snap is heard. If a snap is not heard, the motor 

may need to cool further.

4.  The unit is ready.

Содержание 8513541

Страница 1: ...User Manual 8513541 V 3 03 Please read and understand all instructions before use Retain this manual for future reference 1 2 HP Totally Enclosed Fan Cooled Electric Motor...

Страница 2: ...r Phase 1 Full Load Speed 1 755 RPM Motor Type C Face Frame Type 56H Insulation Type Class F Overload Protection Manual Shaft Diameter 5 8 in Rotation Direction Reversible Voltage Single Phase 115 208...

Страница 3: ...or death if the proper precautions are not taken WARNING This notice indicates a specific hazard or unsafe practice that could result in severe personal injury or death if the proper precautions are n...

Страница 4: ...trical and IEC72 1 Mechanical specifications ANSI C51 5 The Canadian Electrical Code CE and local codes and practices OSHA standard 1910 147 titled The Control of Hazardous energy lockout tag out 2 Co...

Страница 5: ...r equipment 5 When wiring an electrically driven device follow all electrical and safety codes as well as the most recent Canadian Electrical Code CE and Canadian Centre for Occupational Health and Sa...

Страница 6: ...ter motor installation is complete a guard of suitable dimensions must be constructed and installed around the motor This guard must prevent personnel from coming in contact with any moving parts of t...

Страница 7: ...am When using AC motors with frequency inverters be certain that the motors maximum speed rating is not exceeded The wiring fusing and grounding must comply with the Canadian Electrical Code CE or Int...

Страница 8: ...device may present a hazard to the user and or others CONDENSATE DRAINS The motor comes with one way sintered brass breather drains These drains allow the motor to expel liquids from the casing withou...

Страница 9: ...he motor If the motor operates normally then the issue is with the load attached to the motor Should the motor still not work have it serviced or replaced by a qualified technician Power enters contro...

Страница 10: ...ted ground Reconnect or replace the ground wire and test for proper ground Hot power lead is connecting to the motor frame Have a qualified technician inspect the motor and repair replace the defectiv...

Страница 11: ...ean clear all ventilation openings Use dry compressed air if blowing debris out of the ventilation openings Excessive vibration or noise Excessive end play in motor 1 An unbalanced motor or load creat...

Страница 12: ......

Страница 13: ...endre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard Manuel d utilisateur 8513541 V 3 03 Moteur lectrique de 1 2 CV enti rement enferm r...

Страница 14: ...du moteur 1 Vitesse avec pleine charge 1 755 tr min Type de moteur Face en C Type de cadre 56H Type d isolant Cat gorie F Protection contre les surcharges Manuel Arbre Diam tre 5 8 po Sens de rotatio...

Страница 15: ...is de danger qui sont pr sent s dans ce manuel Un avis est une alerte indiquant qu il existe un risque de dommage la propri t de blessure ou de d c s si on ne respecte pas certaines instructions DANGE...

Страница 16: ...s sont n cessaires afin d avoir un meilleur contr le en cas de situations inattendues CONSIGNES DE S CURIT SP CIFIQUES DANGER Seul le personnel comp tent et ayant suivi une formation touchant l insta...

Страница 17: ...ranch dans une prise de courant correctement mise la masse 1 D connectez l outil de la source d nergie avant le nettoyage l entretien le remplacement de pi ces ou d accessoires ou lorsqu il n est pas...

Страница 18: ...it en r sulter un bris pr matur des roulements ou de l arbre Couplage direct Les moteurs couplage direct doivent tre align s avec pr cision alors que l arbre devrait tourner librement sans grippage ou...

Страница 19: ...r caution il pourrait en r sulter des blessures corporelles Branchez le moteur de la fa on indiqu e sur le sch ma de branchement qui appara t sur la plaque signal tique du moteur Assurez vous d identi...

Страница 20: ...e que l tiquette et la plaque signal tique demeurent intactes sur l outil Elles comportent des renseignements importants Si elles sont illisibles ou manquantes communiquez avec Princess Auto Ltd pour...

Страница 21: ...r le moteur L interrupteur thermique est ouvert Replacez l interrupteur thermique l tat initial mais soyez prudent puisque le moteur pourrait red marrer automatiquement au moment de la remise l tat in...

Страница 22: ...it se situer 10 pr s de la tension indiqu e sur la plaque signal tique du moteur D branchez la charge et appliquez le courant au niveau du moteur Si le moteur fonctionne normalement le probl me se sit...

Страница 23: ...oteur de sa charge et v rifiez le courant consomm lorsqu il fonctionne sans charge 4 Si la consommation de courant est excessive sous charge mais normale lorsqu il n y a aucune charge v rifiez la char...

Страница 24: ...udinal excessif ou des pi ces desserr es 2 R alignez le moteur et la charge V rifiez le jeu longitudinal en essayant de d placer l arbre moteur vers l int rieur et vers l ext rieur Ajoutez des rondell...