background image

04

25

Safety

Do not connect to a building’s electrical system unless an isolation switch has been
installed by a qualified electrician.

Using a generator or an electrical appliance in wet conditions such as rain or snow
or near a pool or sprinkler system, or when your hands are wet, could result in
electrocution. Keep the generator dry.

Operator Responsibility

• Know how to stop the generator quickly in case of emergency. (See Page 18)
• Understand the use of all generator controls, output receptacles and connections.
• Be sure that anyone who operates the generator receives proper instruction.

Do not let children operate the generator.

SAFETY INFORMATION

Generators are designed to give safe and dependable service if operated according to instructions.
Read and understand this user’s manual before operating your generator. You can help prevent
accidents by being familiar with your generator’s controls and by observing safe operating
procedures.

Troubleshooting

Helpline No. UK / Northern Ireland 08707 323023    Rep. Ireland 1800 481 005

Web Support : www.omegawolf.com/powercraft

Model Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023    Rep. Ireland 1800 481 005

Web Support : www.omegawolf.com/powercraft

Model Number: PC2800LR

Содержание PC2800LR

Страница 1: ...umber given below Office hours are as follows Mon Fri 8 00am 6 00pm Saturday 8 00am 2 00pm Sunday 10 00am 4 00pm Omega Wolf Ltd Prospect Close Lowmoor Business Park Kirkby In Ashfield Nottinghamshire NG17 7LF UK UK NORTHERN IRELAND 08707 323023 REPUBLIC OF IRELAND 1800 481 005 www omegawolf com powercraft Name Address Contact Telephone No Email Location of purchase Fault Description 2 800W DUAL VO...

Страница 2: ...f the date of purchase The guarantee period can only be extended for the duration of any repair required During the warranty period defective devices can be sent FREIGHT PREPAID to the service address stated at the end of this booklet We will at our discretion either repair or exchange the device in accordance with warranty legislation Please include the following when sending in your product for ...

Страница 3: ...and without incurring any obligation No part of this publication may be reproduced without written permission Safety Message Your safety and the safety of others are very important We have provided important safety messages in this manual and on the generator Please read these messages carefully Specification MODEL PC2800LR Max Output Watts 2800 Cont Output Watts 2500 Phase Single Rated Voltage 23...

Страница 4: ... Be sure that anyone who operates the generator receives proper instruction Do not let children operate the generator SAFETY INFORMATION Generators are designed to give safe and dependable service if operated according to instructions Read and understand this user s manual before operating your generator You can help prevent accidents by being familiar with your generator s controls and by observi...

Страница 5: ...omes very hot during operation and remains hot for a while after stopping the engine Be careful not to touch the silencer while it is hot Let the engine cool before storing the generator indoors Petrol is extremely flammable and is explosive under certain conditions Do not smoke or allow flames or sparks where the generator is refueled or where petrol is stored Refuel in a well ventilated area wit...

Страница 6: ...etrol and add some petrol conditioner Drain the carburetor float bowl Drain the fuel sediment bowl Remove the spark plug Put a tablespoon of engine oil into the cylinder Turn the engine slowly with the pull rope to distribute the oil Reinstall the spark plug Change the engine oil After removal from storage drain the stored petrol into a suitable container and fill with fresh petrol before starting...

Страница 7: ...move the spark plug 4 Visually inspect the spark plug Discard it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 5 Measure the plug gap with a feeler gauge Correct as necessary by carefully bending the side electrode The gap should be 0 70 0 80 mm 0 028 0 031 in 6 Check that the spark plug washer is in good condition and thread the spark plug in ...

Страница 8: ...arm water then rinse thoroughly or wash in nonflammable or high flash point solvent Allow the element to dry thoroughly 3 Soak the element in clean engine oil and squeeze out the excess oil The engine will smoke during initial start up if too much oil is left in the element 4 Reinstall the air filter element and the cover Fuel Sediment Bowl Cleaning The sediment bowl prevents dirt or water which m...

Страница 9: ...ug securely 3 Refill with the recommended oil and check the level Oil capacity 0 6 Litres Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically shut down the engine the engine switch will remain in the ON position Pi...

Страница 10: ...ptacles The system earth is not connected to the AC neutral wire The earth terminal can be used to earth the generator or bond the frame of the generator to the frame of a vehicle but only if it is required by local law or electrical code Before using the earth terminal consult a qualified electrician or electrical inspector for regulations Maintenance Periodic maintenance and adjustment is necess...

Страница 11: ...used for no more than 5 minutes NOTICE Substantial overloading will trip the circuit breaker Exceeding the time limit for maximum power operation or slightly overloading the generator may not switch the circuit breaker OFF but will shorten the service life of the generator Limit operation requiring maximum power to 5 minutes Maximum power is See specifications For continuous operation do not excee...

Страница 12: ...ill trip the DC circuit protector PUSH button extends out If this happens wait a few minutes before pushing in the circuit protector to resume operation If the circuit protector continues to go OFF discontinue charging and contact the helpline Generator Use Starting the engine STARTING THE ENGINE 1 Make sure to disconnect all electrical loads from panel receptacles The generator may be difficult t...

Страница 13: ...notice any undesirable operating symptoms switch to a conventional unleaded petrol Fuel system damage or performance problems resulting from the use of an oxygenated fuel are not the responsibility of the manufacturer and are not covered under warranty NOTICE Oxygenated fuels can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not ...

Страница 14: ... sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling Spilled fuel or fuel vapour may ignite If any fuel is spilled make sure the area is dry before starting the engine Avoid repeated or prolonged contact with skin or breathing of vapour KEEP OUT OF REACH OF CHILDREN Fuel tank capacity 15 Litres Use petrol with a pump octane rating of 86 or higher We recomm...

Отзывы: