Generator Use
Stopping the engine
In an emergency:
1. To stop the engine in an emergency, turn the engine switch to the OFF position. See step 3.
In normal use:
1. Turn the AC circuit breaker to the OFF position.
2. Disconnect all electrical loads from panel receptacles.
Disconnect DC battery charging cables.
3. Turn the engine switch to the OFF position.
4. Turn the fuel valve to the OFF position.
STOPPING THE ENGINE
DC Circuit Protector
Earth
Terminal
DC 12
Circuit
Breaker
AC Applications
Before connecting an appliance or power cord to the generator;
Make sure that it is in good working order. Faulty appliances or power cords can create a
potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off
immediately. Disconnect the appliance, and determine whether the problem is the appliance,
or if the rated load capacity of the generator has been exceeded.
Make sure that the electrical rating of the tool or appliance does not exceed that of the
generator, Never exceed the maximum power rating of the generator. Power levels between
rated and maximum may be used for no more than 5 minutes.
NOTICE
Substantial overloading will trip the circuit breaker. Exceeding the time limit for
maximum power operation or slightly overloading the generator may not switch
the circuit breaker OFF, but will shorten the service life of the generator.
Limit operation requiring maximum power to 5 minutes.
Maximum power is: See specifications.
For continuous operation, do not exceed the rated power.
Rated power is: See specifications.
In either case, the total power requirements (watts) of all appliances connected must be
considered. Appliance and power tool manufactures usually list rating information near the
model number or serial number.
AC Operation
1. Start the engine.
2. Switch ON the AC circuit breaker.
3. Plug in the appliance.
Most motorised appliances
require more than their rated
wattage for startup.
Do not exceed the current limit specified for any one socket. If an overloaded circuit causes
the AC circuit breaker to switch OFF, reduce the electrical load on the circuit, wait a few minutes
and then reset the circuit-breaker.