background image

 

Remote Heat Station 

40kW; 35 – 400kHz 

User’s Guide 

 

RHS-40 

 

 

Rev. A 

 

 

1/4/10 

Содержание RHS-40

Страница 1: ...Remote Heat Station 40kW 35 400kHz User s Guide RHS 40 Rev A 1 4 10...

Страница 2: ...Table of Contents 1 SPECIFICATIONS AND FEATURES 3 2 GETTING STARTED 4 3 CONNECTIONS 5 4 LOAD STATION TUNING 6 2...

Страница 3: ...Resonant capacitors Mounting space provided for eight capacitors 1 4 Load Quality factor of load Will operate with any load Q including resistive loads provided that the output frequency and voltage...

Страница 4: ...n hazard at the outputs when the unit is operating Disconnect input power before installing or servicing this unit Operation of this unit may be initiated at the power supply without knowledge of serv...

Страница 5: ...t Station to an induction power supply load and cooling water Figure 1 Load connections A coil mounts to the output blocks with four 1 4 20 screws 3 1 Load Mount the heating coil to the front of the u...

Страница 6: ...s initiating the heat cycle from the power supply controls is more convenient 4 Load station tuning WARNING Make sure that power supply is turned off before adjusting heat station components This sect...

Страница 7: ...onnections from an input block Connect an oscilloscope to the output of the Remote Heat Station Momentarily touch a DC voltage source about 85VDC to the two leads of the RHS The scope should show the...

Страница 8: ...S resonance frequency then the capacitance in the Power Supply can be lowered or the series inductor can be adjusted for lower inductance If the frequency is higher than the load frequency the capacit...

Отзывы: