2. Getting started 

2.1.   Safety Warnings 

 

Have all operation, maintenance and servicing performed by qualified personnel only. 

 

1. 

Read this operation manual completely before using the power supply. 

2. 

Induction heating can be dangerous.

  Obey all warnings on unit and in manual. 

3. 

Do not touch live electrical parts.

  In operation, this means the output connectors, 

the work coil, the work piece, and any buswork or cabling connecting them.

 

  

 

 

 

WARNING:

  These symbols, placed at the outputs of the power 

supply, warn of the electric shock hazard there and RF burn 
hazard at the outputs when the unit is operating. 

 

  

 

  

 

Disconnect input power before installing or servicing this 
unit.

  Operation of this unit may be initiated at the power supply 

without knowledge of service personnel. 

2.2.   Set-Up 

The following is a list of steps describing the required actions to get the power supply set up. 
1.  Remove the fourteen ¼-20 screws from the cover and remove the cover. 
2.  Connect the heating coil to the output of the unit (see section 

 

3.1. on page 5).  

3.  Connect and test the cooling water supply, as described in section 

 

3.3. on page 6.  

4.  Load capacitors onto the capacitor bus as described in 

 

4.1. on page 6

5.  Connect control wiring plug to power supply as described on 3.4 on page 6. 
6.  The unit is now ready for operation,. 

 

4

Содержание RHS-40

Страница 1: ...Remote Heat Station 40kW 35 400kHz User s Guide RHS 40 Rev A 1 4 10...

Страница 2: ...Table of Contents 1 SPECIFICATIONS AND FEATURES 3 2 GETTING STARTED 4 3 CONNECTIONS 5 4 LOAD STATION TUNING 6 2...

Страница 3: ...Resonant capacitors Mounting space provided for eight capacitors 1 4 Load Quality factor of load Will operate with any load Q including resistive loads provided that the output frequency and voltage...

Страница 4: ...n hazard at the outputs when the unit is operating Disconnect input power before installing or servicing this unit Operation of this unit may be initiated at the power supply without knowledge of serv...

Страница 5: ...t Station to an induction power supply load and cooling water Figure 1 Load connections A coil mounts to the output blocks with four 1 4 20 screws 3 1 Load Mount the heating coil to the front of the u...

Страница 6: ...s initiating the heat cycle from the power supply controls is more convenient 4 Load station tuning WARNING Make sure that power supply is turned off before adjusting heat station components This sect...

Страница 7: ...onnections from an input block Connect an oscilloscope to the output of the Remote Heat Station Momentarily touch a DC voltage source about 85VDC to the two leads of the RHS The scope should show the...

Страница 8: ...S resonance frequency then the capacitance in the Power Supply can be lowered or the series inductor can be adjusted for lower inductance If the frequency is higher than the load frequency the capacit...

Отзывы: