7. Fault Finding Guide - Page 32
S
U
P
0
1
3
6
B
Do RED, GREEN LEDS & Water
Pump come on together for
approx 3 seconds followed
by RED LED only
Do RED, GREEN LEDS and
Water Pump come on together
for approx 3 seconds followed
by GREEN LED flashing with
RED LED on continuously?
Turn off EXTERNAL CALL
for heat
Has Fuse F1 on the Electronic
Board blown?
Has External Circuit Breaker
tripped, or External Fuse blown?
Investigate Overcurrent fault &
repair. (In particular, suspect
appliance FAN & System
WATER PUMP).
Is PERM. Live supply present
Sw Live & Permanent
Live are reversed.
Correct Wiring to appliance
After approx. 7 seconds,
does GREEN LED flash rapidly?
(16Hz)
Mains Supply is
NOT OFF
Check external
wiring
Is the RED LED flashing?
Are any LED's on?
PRESS RESET
Turn on EXTERNAL CALL
for HEAT
Check external
controls are giving
Sw LIVE supply
Is the Fan running
Replace Air Pressure Switch
Isolate Electricity Supply.
Is the Air Pressure
Switch Contacting,
CLOSED CIRCUIT?
Replace
the
Fan
After 1 minute, does RED LED
FLASH & GREEN LED come
on continuously?
Apply Permanent Mains Supply
Is the RED LED on only?
Is the RED LED still on?
Is the GREEN LED flashing?
(Slowly 2Hz)
Turn Boiler 'Stat on to MAXIMUM'
Does RED LED extinguish?
Turn on EXTERNAL CALL for heat
Are all the lights OFF?
Press
RESET Button
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
Replace Temperature Sensor
Replace Temperature Control
Assembly
Isolate the Electricity Supply,
is the Temperature Sensor
Short Circuiting?
Electrically isolate the appliance.
With Temp. Control on MAX.,
is there a Short Curcuit between
the ORANGE leads of the
Temp. Control Assembly?
With appliance electrically
isolated, & Temp. Control
on MAX., is there a
Short Curcuit between
the WHITE leads of the
Temp. Control Assembly?
NO
NO
NO
NO
Fault Finding Guide For 100 Model
Page 1
To
Page
To
Page
2
2
INITIAL CONDITIONS
1. All Electric Power Off.
2. No External Call for Heat.
3. Boiler Thermostat to '0' (Off)
4. Check Gas Supply is ON
Содержание Suprima 100
Страница 10: ...Installation Requirements Page 10 ...
Страница 12: ...Flue Kits Page 12 Installation instructions included as necessary with each kit ...
Страница 13: ...Other Kits Page 13 Installation instructions included as necessary with each kit ...
Страница 31: ...6 Wiring Diagram Page 31 ...
Страница 32: ......
Страница 34: ...7 Fault Finding Guide Page 33 ...
Страница 36: ......
Страница 37: ...8 Short List of Spare Parts Page 34 SUP0083D L 365mm L 365mm L 462mm L 476mm ...