IMPORTANT:
• Only
ONE
25mm clearance is allowed per installation.
• Under car ports we recommend the use of the plume
displacement kit.
• The terminal position must ensure the safe and
nuisance - free dispersal of combustion products.
N
I
I
G
F
M
I
A
A
F
H
J,K
D
E
H
Likely flue positions requiring
a flue terminal guard
C
R
A
I
J,K
I
L
S
B
T
U
Fig. 8
Fig. 9
300 min
Terminal
Assembly
Top View Rear Flue
Property Boundary Line
NOTE:
The distance from a fanned draught appliance
terminal installed parallel to a boundary may not be less
than 300mm in accordance with the diagram below
Terminal Position with Minimum Distance (Fig. 8)
(mm)
Aa Directly below an opening, air brick, opening windows, etc
300
Ba Above an opening, air brick, opening window etc.
300
Ca Horizontally to an opening, air brick, opening window etc.
300
D
Below gutters, soil pipes or drain pipes.
25
E
Below eaves.
25
F
Below balconies or car port roof.
25
G From a vertical drain pipe or soil pipe.
25
H
From an internal or external corner.
25
I
Above ground, roof or balcony level.
300
J
From a surface or boundary line facing a terminal.
600
K
From a terminal facing a terminal (Horizontal flue).
1200
From a terminal facing a terminal (Vertical flue).
600
L
From an opening in carport (e.g. door, window)
into the dwelling.
1200
M Vertically from a terminal on the same wall.
1500
N
Horizontally from a terminal on the same wall.
300
R
From adjacent wall to flue (vertical only).
300
S
From an adjacent opening window (vertical only).
1000
T
Adjacent to windows or openings on pitched and flat roofs
600
U
Below windows or openings on pitched roofs
2000
a In addition, the terminal should be no nearer than 150 mm to an
opening in the building fabric formed for the purpose of accommodating
a built-in element such as a window frame. See BS 5440 Pt. 1.
*
Opening
Window or Door
100mm
MIN.
IMPORTANT:
If fitting a Plume Displacement Flue Kit,
the air inlet must be a minimum of 100mm from any
opening windows or doors (see Plume Displacement
Section 3.9).
Plume
Displacement
Kit
Air Inlet
Fig. 10