POTTERTON Gas condensing boiler, Series PARAMOUNT 40 / 60
4)
4)
1) Optional extras
2) When RRG is connected, remove jumper at N5
( optimum operation )
3) Remove resistor for connection of B3!
4) Only Paramount 60
X2-01
1
2
X2-02
1
2
X2-03
1
2
X2-04
1
2
3
X2-05
1
N1/X1
X2
X50
X30
X40
X10
X11
X12
X13
X14
X15
1
2
3
1
2
X1-01
X1-02
E1
Terminal 1 - 14
F4
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
1
2
3
M
M4
F 10
230 V.AC
24 V.DC
1
2
3
1
2
3
X9
X5
3
3
2
2
4
4
5
5
1
1
S1
Line voltage 230V 50 Hz
Low voltage
N2
F1
12
1
2
B2.1
1
2
1
2
B2.2
1
2
bl
br
rt
rs
vi
b l
rt
or
or
1
2
3
1
2
1
2
3
1
1
2
Boiler
module
H1
H2
H5
H4
N3
P2
H3
S2
S3
S4
B5
2)
N5
B3
3)
B9
1
2
3
4
5
6
7
8
9
10
11
12
1
2
X6
1
2
1
2
1
2
1
2
F7
B5
N5
F7
B3
B9
R3
F2
X10-04
X10-05
X10-06
1
2
1
2
1
2
1
2
1
2
1
2
X10-01
X10-02
X10-03
sw
ws
rt
b l
X3-01
X3-02
X3-03
X3-04
1
2
1
2
1
2
1
X3
bl
br
T1
Y2
1
2
3
1
2
1
2
1
2
M
M1
X1
1
X7
L
N
LINE POWER
230V 50 Hz
2
N
N
L
L
M
N
L
M3
L
N
L
N
L
N
1)
Line Power
M1
M5
M3
1
2
H1 Fault indicator ( red )
H2 Burner operating indicator ( green )
H3 Operation state indicator
H4 Temperature display
H5 P display
K3 Fault
connector
K5 0-10 V DC relay module
Status
displays
Legend:
B2.1 Boiler flow sensor QAK 36.670
B2.2 Boiler return sensor QAL 36
B3 Tank sensor QAZ 36
1)
B5 Room control module RRG
(type QAA 73)
1)2)
B9 Outdoor temperature sensor QAC 34
E1 Ionization electrode
F1 Fuse T6.3A
F2 Programmable input
F3 Safe temperature limiter 110°C
F4 Water pressure monitor
M1 Pump, pump heating circuit
M3 Tank charging pump
1)
T1 Ignation
tranformer
Y2 Gas
solenoid valve ( 230 V AC )
X1 Terminal
strip LINE POWER
X5 Terminal strip
X6 Terminal strip, sensor
X7 Terminal strip, pump M1
X9 Terminal strip, fan
M4 Fan
M5 Programmable output
N1 Control center LMU 64.001 A 100
N2 Boiler module
N3 Heating circuit module HKM
N5 Room temperature regulator / timer
1)
N11 0-10 V DC signal
P2 Time clock
S1 Operating switch
S2 Reset button
S3 Display mode button
S4 Chimney sweep button
R3 Substitute
resistor 1 K Ohm
Resistance values for sensor
Outdoor tempera-
Boiler sensor B2, Tank sensor B3
ture
sensor B9,
°C
°C
°C
-20
8194
0
32555
55 2989
-15
6256
5
25339
60 2490
-10
4825
10
19873
65 2084
-5
3758
15
15699
70 1753
0
2954
20
12488
75 1481
5
2342
25
10000
80 1256
10
1872
30
8059
85 1070
15
1508
35
6535
90 915
20
1224
40
5330
95 786
25
1000
45
4372
100 677
30
823 50 3605
br
gnge
b l
gnge
bl
br
gnge
bl
br
Note:
Circulating Pumps max. current
load per pump output in I < 1A
N max
T6.3A
N4
K1
F10 Fuse
(burner fan)
b l
br
gnge
F7 Safty
interlock
br = brown
gnge = green/yellow
bl = blue
rt = red
sw = black
rs = pink
vi = violet
or = orange
ws = white
F3
P
F5
F5 Gas
pressure monitor
K5
1
2
1
2
1
2
3
L
N
L
N
N
L
L
1
2
K3
L3
L2
L1
N
N
N
1
2
3
4
5
7
6
Relais 1
Relais 2
Relais 3
rt
b l
br
sw
1
2
H1
H2
X51
X52
1
2
1
2
3
1
2
0-10V DC
N11
N1 Central control BMU ( LMU 64.001 A 100 ) SW > 2.08
H3
b l
INSTALLATION, OPERATION AND MAINTENANCE MANUAL SECTION 7
PARAMOUNT
PAGE 35