Fault Indication

1. If a fault occurs on the boiler an error code may
be shown on the facia display.

2. The codes are either two or three digit,
preceded by the letter 'E'. For example, code E133
will be displayed by 'E1' alternating with '33'. E50
is shown as 'E' then '50'.

3. E20, E28, E50, E125 & E160 indicate faulty
components. You should make a note of the
displayed error code and contact your installer or
service engineer.

4. If E110 or E130 is displayed overheat of the
primary water or flue system has occurred. Turn
the selector switch to the reset position and hold
for at least 5 seconds. If the boiler does not relight,
or the code is displayed regularly contact your
installer or service engineer.

5. E119 is displayed when the primary water
pressure is less than 0.5 bar. After repressurising
the system the boiler should operate. Your
installer will be able to advise you about the
method of repressurising. See page 6 for further
details. 

6. E133 indicates that the gas supply has been
interrupted, ignition has failed or the flame has not
been detected. Ensure that the gas supply has not
been turned off, and turn the selector switch to the
reset position and hold for at least 5 seconds. If
the boiler does not relight, or the code is displayed
regularly contact your installer or service engineer.

Resetting 

(Fig. 8)

1. To reset the boiler turn the selector switch fully
anticlockwise against the spring pressure for
approximately 5 seconds and release.

Pump Protection

1. With the selector switch in either Position (i) or
Position (ii) (Figs. 7 & 9) the pump will
automatically operate for 1 minute in every 24
hours to prevent sticking.

3-Way Valve - Anti-sticking

1. If there is no demand for heat in a 24 hour
period, the 3-way valve will be operated once to
help prevent sticking.

Central Heating NTC Fault

Flue NTC Fault

Hot Water NTC Fault 

Safety Thermostat Operated

Water Pressure Switch Not Operated

Pump Fault

Flue NTC Operated

Interruption Of Gas Supply or Flame Failure

Fan or Fan Wiring Fault

E20

E28

E50

E110

E119

E125

E130

E133

E160

Table of Error Codes

2

1

0

4

3

bar

Reset

1

2

3

4

5

PM

7

8

9

10

11

12

1

2

3

4

5

AM

7

8

9

10

11

12

GRASSLIN

0

Display

Then

Fig. 6

Reset

Reset

Fig. 7

Fig. 9

Reset

Reset Position

Fig. 8

Position (ii)

(Hot Water)

Position (i)

(Central Heating or Hot Water)

Содержание Gold Combi HE

Страница 1: ...s 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Body 0085 For use in GB IE only Please read this document and keep it safe It will help you out should your boile...

Страница 2: ...n the unlikely event your boiler develops a fault and your installer is unable to assist heateam will provide a free service to you provided the boiler is under 3 years old Otherwise heateam will offer a competitive fixed price repair rate including parts labour and VAT To arrange an engineer visit either in warranty or out please call heateam on 08706 017 017 It would help if you had your boiler ...

Страница 3: ... etc or domestic hot water will be provided when a tap or shower is turned on Priority is given to domestic hot water The central heating indicator will illuminate when the boiler is supplying central heating If there is a demand for domestic hot water the indicator will illuminate and the central heating indicator will extinguish Fig 2 As the temperature rises the display will change showing the ...

Страница 4: ...e has not been detected Ensure that the gas supply has not been turned off and turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your installer or service engineer Resetting Fig 8 1 To reset the boiler turn the selector switch fully anticlockwise against the spring pressure for approximately 5 se...

Страница 5: ...of the domestic hot water can be adjusted by turning the control knob clockwise to increase up to a maximum of 60 C Fig 11 As the control knob is turned the selected temperature is displayed for approximately 4 seconds The display then reverts to the current boiler output temperature 5 The temperature of the water is also dependent on the water flow rate and the temperature of the mains coming int...

Страница 6: ...g 15 Error Code E119 will be shown on the display To Shut Off the Boiler 1 For short periods Turn the selector switch to the OFF position Fig 16 2 For long periods Turn off the selector switch Fig 16 electricity and gas supplies If your home is to be left unoccupied for long periods during cold weather the boiler and whole system should be drained unless there is additional frost protection 3 Your...

Страница 7: ...vide a competitive fixed price repair rate including parts labour and VAT To find out more call heateam on 08706 017 017 open Monday to Friday 8am 6pm weekends and bank holidays 8 30am 2pm closed on Christmas and New Years Day An appointment convenient for you can be arranged It would help if you had your boiler serial number when you call the serial number is shown on the back cover of this guide...

Страница 8: ... operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappets are set to th...

Страница 9: ...r boiler Your boiler should have the following minimum clearances for Safety and Maintenance Figs 19 20 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings Flammable materials must not be stored in close proximity to yo...

Страница 10: ... Page 4 No Continue below 3 Is the gas supply turned on 4 Is the mains water supply turned on 5 Is the system pressure correct 6 Is the programmer or timer switch set to On Refer to the instruction booklet supplied with these items for correct setting and operation 7 Are the temperature controls on the boiler turned on and set high enough 8 Are all system controls such as room and cylinder thermos...

Страница 11: ...rson Warning In an Emergency If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Turn off the electrical supply and turn the selector switch on the facia box to the OFF position 2 Using a suitable open ended spanner or screwdriver turn the square on the gas tap to the left to isolate the gas supply at the boiler Fig 19 3 The isolating valves ar...

Страница 12: ...nd offer a free warranty service within 3 years of installation of the boiler If you are unable to provide this information or the boiler has been installed for over 3 years heateam will charge a competitive rate for the repair The engineer when visiting will verify if the boiler is under the free 3 years warranty service in this case heateam will provide a full refund If you have contacted your i...

Отзывы: