background image

Publication No.

5116283 - Iss.

(07/2005)

Serial Number

Date of Installation

Installer Details (name, address and contact number(s)

Please complete the boxes below

heateam

heateam

is the national customer service division of

Baxi Potterton providing a free warranty service within 
3 years of installation of your boiler. If your installer is
unable to rectify your boiler fault, by contacting one of
our friendly advisors we can arrange an engineer if
required.

When calling 

heateam 

it would be helpful if you could

have the following information to hand:

1

Boiler serial number.

2

Boiler make and model number.

3

Your installer name and address details.

4

Proof of purchase (if you do not have the 
boiler serial number).

heateam

will verify the boiler age via the serial number

and offer a free warranty service within 3 years of
installation of the boiler. If you are unable to provide this
information or the boiler has been installed for over 
3 years, 

heateam

will charge a competitive rate for the

repair. The engineer when visiting will verify if the boiler
is under the free 3 years warranty service, in this case

heateam

will provide a full refund.

If you have contacted your installer and they are unable
to assist you at this time, please contact 

heateam

.

heateam

is open Monday to Friday 8am - 6pm,

weekends and bank holidays 8.30am - 2pm, closed on
Christmas and New Years Day.

Telephone 

08706 017 017

*

*

To aid in continuous improvement and staff training, calls 

to  this line may be monitored or recorded.

B A X I   P O T T E R T O N

A Trading Division of Baxi Heating UK Ltd

Brownedge Road Bamber Bridge Preston Lancashire PR5 6UP
After Sales Service 08706 017 017 Technical Enquiries 08706 049 049
Website www.potterton.co.uk

company

924.176.2

Information Label

Содержание Gold Combi HE

Страница 1: ...s 1993 No 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0085 Product Production certified by Notified Body 0085 For use in GB IE only Please read this document and keep it safe It will help you out should your boile...

Страница 2: ...n the unlikely event your boiler develops a fault and your installer is unable to assist heateam will provide a free service to you provided the boiler is under 3 years old Otherwise heateam will offer a competitive fixed price repair rate including parts labour and VAT To arrange an engineer visit either in warranty or out please call heateam on 08706 017 017 It would help if you had your boiler ...

Страница 3: ... etc or domestic hot water will be provided when a tap or shower is turned on Priority is given to domestic hot water The central heating indicator will illuminate when the boiler is supplying central heating If there is a demand for domestic hot water the indicator will illuminate and the central heating indicator will extinguish Fig 2 As the temperature rises the display will change showing the ...

Страница 4: ...e has not been detected Ensure that the gas supply has not been turned off and turn the selector switch to the reset position and hold for at least 5 seconds If the boiler does not relight or the code is displayed regularly contact your installer or service engineer Resetting Fig 8 1 To reset the boiler turn the selector switch fully anticlockwise against the spring pressure for approximately 5 se...

Страница 5: ...of the domestic hot water can be adjusted by turning the control knob clockwise to increase up to a maximum of 60 C Fig 11 As the control knob is turned the selected temperature is displayed for approximately 4 seconds The display then reverts to the current boiler output temperature 5 The temperature of the water is also dependent on the water flow rate and the temperature of the mains coming int...

Страница 6: ...g 15 Error Code E119 will be shown on the display To Shut Off the Boiler 1 For short periods Turn the selector switch to the OFF position Fig 16 2 For long periods Turn off the selector switch Fig 16 electricity and gas supplies If your home is to be left unoccupied for long periods during cold weather the boiler and whole system should be drained unless there is additional frost protection 3 Your...

Страница 7: ...vide a competitive fixed price repair rate including parts labour and VAT To find out more call heateam on 08706 017 017 open Monday to Friday 8am 6pm weekends and bank holidays 8 30am 2pm closed on Christmas and New Years Day An appointment convenient for you can be arranged It would help if you had your boiler serial number when you call the serial number is shown on the back cover of this guide...

Страница 8: ... operate on demand To set the time of day Turn the timer outer bezel clockwise to align the pointer with the correct time to the nearest 15 minutes ensuring that A M P M is considered Do not at any time attempt to turn the bezel anti clockwise To set the timed heating program Decide which times of the day the central heating is required The heating will operate when the white tappets are set to th...

Страница 9: ...r boiler Your boiler should have the following minimum clearances for Safety and Maintenance Figs 19 20 Top 200mm Bottom 200mm Left side 5mm Right Side 5mm Front 5mm In Operation 450mm For Servicing If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings Flammable materials must not be stored in close proximity to yo...

Страница 10: ... Page 4 No Continue below 3 Is the gas supply turned on 4 Is the mains water supply turned on 5 Is the system pressure correct 6 Is the programmer or timer switch set to On Refer to the instruction booklet supplied with these items for correct setting and operation 7 Are the temperature controls on the boiler turned on and set high enough 8 Are all system controls such as room and cylinder thermos...

Страница 11: ...rson Warning In an Emergency If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Turn off the electrical supply and turn the selector switch on the facia box to the OFF position 2 Using a suitable open ended spanner or screwdriver turn the square on the gas tap to the left to isolate the gas supply at the boiler Fig 19 3 The isolating valves ar...

Страница 12: ...nd offer a free warranty service within 3 years of installation of the boiler If you are unable to provide this information or the boiler has been installed for over 3 years heateam will charge a competitive rate for the repair The engineer when visiting will verify if the boiler is under the free 3 years warranty service in this case heateam will provide a full refund If you have contacted your i...

Отзывы: