9.3.10 Diverter valve motor
1. Disconnect the multi-pin plug from the diverter valve motor.
2. Hold the motor in place against the spring pressure of the valve as
sembly, remove the securing clip.
3. Remove the motor.
4. When fitting the new motor it will be necessary to hold the unit firmly
while depressing the valve assembly spring to refit the securing clip.
5. Reconnect the multi-pin plug.
9.3.11 Expansion vessel
Warning
Take precautions to protect other components from water damage
when removing the expansion vessel.
1. Close the flow and return isolation taps and drain the boiler primary
circuit.
2. Relieve the pressure from the expansion vessel.
3. Remove the silencer.
4. Prise off the securing clips and disconnect the braided hose from the
vessel and hydraulic inlet assembly, taking care as water may still
be in the vessel.
5. Ensure that the braided hose is free of restriction, as a boiler with a
blocked hose will exhibit symptoms similar to one with a failed ves
sel.
Important
Where the hose is found to be blocked, it must be cleared or re
placed and the vessel recharged to 1 bar.
6. If the hose is clear support the vessel, undo the locknut and ma
noeuvre the vessel out of the boiler.
7. Replace the expansion vessel with the new one and reassemble in
reverse order and recharge to 1 bar.
9.3.12 Gas valve
Tab.23 Characteristics of combustion
Potterton Assure Combi
25
30
CO
2
% (maximum) 9.0 + 0.3 – 0.2
9.0 + 0.3 – 0.2
% (minimum) 8.5 + 0.1 – 0.4
8.5 + 0.1 – 0.4
Diameter of coaxial discharge pipes
mm
60/100 & 80/125
60/100 & 80/125
Fig.58
Remove diverter valve
PN-0000311
Fig.59
Remove expansion vessel
PN-0000378