8 Operation
8.1
Use of the control panel
8.1.1
Control panel
The controls are operated by the control knobs and a reset button.
1
Display screen
2
Reset button
3
CH temperature control knob
4
Service diagnostic port
5
DHW temperature control knob
6
System water pressure gauge
8.2
Start up
If there is no power to the boiler, switch on at the fused spur unit and en
sure that the time control is in the on position and any other controls (e.g.
room thermostat) are calling for heat. The boiler will begin its start se
quence. This procedure performs a series of tests, after which the installa
tion is purged (this takes approximately five minutes).
8.3
Frost protection
Where possible, draining the system should be avoided. If the system is to
be unused during winter months several precautions must be taken:
Any parts of the system that are in unheated areas of the dwelling
should be fitted with a device such as a pipe thermostat or frost thermo
stat.
Power must remain supplied to the boiler and controls.
Gas must remain supplied to the boiler.
The boiler pump will operate if the system temperature drops below 7°C. If
the temperature falls to 4°C the burner will ignite and remain lit until the
temperature reaches 10°C. At this temperature the burner will extinguish
but the pump will continue to operate for 15 minutes. This feature will pro
tect the boiler and to some extent adjacent parts of the system but addi
tional devices must be incorporated to guarantee frost protection.
Fig.44
Control panel
R
Reset
bar
0
1
2
3
4
1
2
3
4
5
6
PN-0000334
Min
M
a
x
M
a
x
Min
8 Operation
7678846 - A - 22052017
51