Postium OBM-U170 Скачать руководство пользователя страница 17

OBM-U170/U240

4K LCD Professional Monitor

with 12G-SDI,  Quad Link  4K

17

Page 4/7

Marker

    - Selects On to display the marker, and Off to
     deac vate it.
   

Aspect Marker

     Selects the aspect ra o of the marker.
     You can select from among [Off], [16:9], [4:3], 
     [4:3 ON AIR], [15:9], [14:9], [13:9], [1.85:1], 
     [2.35:1], [2.39:1], [1.85:1 & 4:3], [1.66:1], 
     [1.896:1], [Variable].
      *

Variable Aspect

        

        Allows the user to select the aspect ra o from
        the range between 1.00:1 and 3.00:1.
   

Center Marker

     Selects On to display the center marker and Off 
     not to display it.      
   

Area Marker

     Selects the size of the area marker.
     You can select from among [Off], [80%], [85%],
     [88%], [90%], [93%], [100%], [EBU Ac on 16:9], 
     [EBU Graphic 16:9], [EBU Ac on 14:9], 
     [EBU Graphic 14:9], [EBU Ac on 4:3], 
     [EBU Graphic 4:3].
   

Color

  

   Selects the color of the marker.

     You can select from among [White], [Gray], [Red],
     [Green], [Blue], [Yellow], [Cyan], [Magenta].

Aspect Mat

     Darkens the outside of the area of the Aspect
     Marker. You can select from 0 to 7.
   

Fit

     With Fit On, the Area Marker is displayed rela ve
     to the Aspect Marker in use.
     With Fit Off, the Area Marker is displayed rela ve
     to the incoming video source.
   

Thickness

    

     Adjusts the thickness of the marker lines.
     You can select it from 1 to 7.  
     ** This menu is ac vated in OBM-U170 model only.

Page 5/7

WFM/Vector

     - Sets to ac vate and deac vate Waveform 
       monitor and Vectorscope.
       You can select from among [WFM], 
       [VectorScope], [WFM+Vector], [WFM Wide].
       *This func on doesn’t work when RGB format
          signal is input.
    

Intensity

       Adjusts the brightness of Waveform and 
       Vectorscope display.  
       You can select from 1 to 64.
    

Transparency 

                      

       Adjusts the transparency level of Waveform and 
       Vectorscope.    
      [Black]: The background is black. Displayed image 
                   is hidden behind the background.
      [Half]: The background is transparent. Displayed
               image can be seen indis nctly behind the
               Waveform and Vectorscope display.
    

Color

      Selects the color of Waveform monitor.
      Available colors are [Green] and [White].
    

Line Select

      Selects [On] to display the Waveform of the line
      assigned in [Line Posi on] below.      
       *

Line Posi on

         Selects the specific horizontal line for 
         Waveform and Vectorscope.
         Increases the value to move the line upwards 
         and decreases the value to move the line 
         downwards.

     ** [WFM Wide] feature is disable on U240 model     

User Configuration Menu

Содержание OBM-U170

Страница 1: ...Professional Video Monitor Operational Instructions OBM U240 OBM U170 User Manual 03 2017...

Страница 2: ...ar Panel 4 Using the Menu 5 Adjustment Using the Menus 6 OSD Menu Operations Status Menu Color Temp Color Space Gamma Menu Zebra Focus Menu User Configuration Menu Remote Menu 7 Scan Mode Image OBM U2...

Страница 3: ...tead of the standard adapter provided by the manufacturer please check the proper load capacity or current capacity and use an adapter with stable voltage Do not overload AC outlets or extension cords...

Страница 4: ...equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc on manual may cause...

Страница 5: ...Link 2 Sample Interleave 2SI 3D LUT for Accurate Color Reproduc on ITU R BT 709 SMPTE C EBU Na ve D CINEMA ITU R BT 2020 Gamma Selec on 1 0 3 0 Color Temperature 3200K 5500K 6500K 9300K USER 1 2 3 D...

Страница 6: ...turn o each func on SCAN Bu on Press the bu on to adjust the scan mode Zero Scan 1 1 Scan ASPECT Bu on Press the bu on to select the Aspect Ra o of the signal Mode changes in the order of 16 9 4 3 2 3...

Страница 7: ...value Focus Frequency When Focus Assist func on is ac vated this mode is displayed Zebra Level When Zebra func on is ac vated this mode is displayed Line Posi on When WFM Vector func on and Line Sele...

Страница 8: ...ls For an HDMI cable High Speed HDMI Cable with the cable type logo or HDMI 2 0 Cable is recommended When inpu ng 4K resolu on 3840 x 2160 or 4096 x 2160 signal use a cable of 3m or less D SFP Input c...

Страница 9: ...y using 10BASE T 100BASE TX LAN cable A daisy chain connec on using the LAN input output connectors enables the control of mul ple monitors in sequence H AUDIO IN connector Stereo mini jack Connector...

Страница 10: ...nu is displayed on the right 4 Make the se ng or adjustment on an item How to change the adjustment level To increase the level turn the SELECT VOLUME knob right To decrease the level turn the SELECT...

Страница 11: ...Aperture Color Space Gamma User Preset RGB Range WFM Vector Audio Level Meter Focus Assist Time Code Volume SDI Payload ID Model Name Serial Number Board Version Opera on Time Last Calibra on Time Ide...

Страница 12: ...4 Page 3 4 Page 4 4 Format Color Temp Brightness Contrast Chroma Aperture Color Space Gamma User Preset RGB Range Back Light WFM Vector Audio Level Meter Focus Assist Time Code Volume SDI Input SDI Pa...

Страница 13: ...00 This mode displays the absolute brightness up to 300cd m So the highlights over 300cd m are clipped HLG 1000 Hybrid Log Gamma This mode can be selected when the White is 1000 cd m in HLG gamma HLG...

Страница 14: ...ects the appropriate gamma mode from 1 00 to 3 00 Note When the OBM HDR is set O this menu becomes ac vated When the color space is set to Na ve this menu becomes deac vated Page 3 3 Camera Log Select...

Страница 15: ...u on Color Space Compare F2 Bu on H V Delay F3 Bu on Color Temp F4 Bu on Audio Level Meter F5 Bu on Time Code Zebra Focus Menu Zebra Evaluates the Luma Y level of the input image If the certain Y leve...

Страница 16: ...y method for Audio Level Meter Available modes are Group and Pair In HDMI input the mode is xed to Pair Reference Selects the default value of Audio Level Meter Available op ons are 18dB and 20dB Size...

Страница 17: ...the Area Marker is displayed rela ve to the incoming video source Thickness Adjusts the thickness of the marker lines You can select it from 1 to 7 This menu is ac vated in OBM U170 model only Page 5...

Страница 18: ...t 608 VBI Selects this mode to display 608 VBI when SD SDI signal is input 608 708 Selects this mode to display 608 708 when D SDI signal is input 708 Sets the Closed Cap on type for 708 Selects from...

Страница 19: ...an mode is selected To see the image on the right end and the le end area the loca on of the image can be moved by rota ng the SELECT VOLUME knob Note When QFHD DCI 4K signal is fed Aspect bu on is no...

Страница 20: ...89 1 4096x2160 it is scaled to1920x1012 1 89 1 If you press Scan bu on and select 1 1 Scan mode 1 1 pixel mapping of the original image is displayed The loca on of the image can be changed by rota ng...

Страница 21: ...ink 3G SDI Signal 2 sample interleave division signals Quad Link 3G HD SDI Signal 2 sample interleave division signals Square division signals Image of Square division signals Sub Image1 upper left sc...

Страница 22: ...bit 2048 x 1080 23 98 24 25 29 97 30p Psf 1280x 720 23 98 24 25 29 97 30 50 59 94 60p 1920 x1080 50 59 94 60p Level A Level B DL Level A Level B DL Level A Level B DL Level A Level B DL Level A 1920 x...

Страница 23: ...4 2 2 YCbCr 12bit 4 4 4 RGB 8bit 4 4 4 YCbCr 8bit 4 2 2 YCbCr 12bit 4 4 4 RGB 10bit 4 4 4 YCbCr 10bit 4 4 4 RGB 12bit 4 4 4 YCbCr 12bit 4 4 4 RGB 10bit 4 4 4 YCbCr 10bit 4 4 4 RGB 12bit 4 4 4 YCbCr 12...

Страница 24: ...ch can t any possible broadcast applica ons Adjustable Gamma Gamma value is adjustable from 1 0 to 3 0 as user s preference to monitor in the dark area of the picture Any pictures taken in either ligh...

Страница 25: ...RH Power Cable Rack Mount Kit Carrying Case V Mount Acrylic Protector Sun Hood 17 only 4 x BNC 1 x HDMI 1 x SFP 4 x BNC SMPTE ST 2082M SMPTE ST 2081M SMPTE 425M AB SMPTE 274M 292M SMPTE 296M SMPTE 260...

Страница 26: ...rofessional Monitor with 12G SDI Quad Link 4K 26 208 Building A Samsong Techno Valley 140 Tongil ro Deogyang gu Goyang si Gyeonggi do Korea 10594 Tel 82 2 354 6055 Fax 82 2 354 6056 E mail sales posti...

Отзывы: