Eight-card Shelf, 751109/13

Description and Installation

Содержание Teleline Isolator 751109/13

Страница 1: ...Eight card Shelf 751109 13 Description and Installation...

Страница 2: ...and 2 shall use same for operating and maintenance purposes only DISCLAIMER NOTICE Although Positron Inc has made every effort to ensure the accuracy of the information contained herein this document...

Страница 3: ...ections 10 5 1 Station Side Cable Connection 11 5 2 CO Side PIC Connection 14 5 3 CO Side Cable Connection Without the PIC Stub 18 6 Power Connections 20 6 1 External Power Supply 20 6 2 Internal Powe...

Страница 4: ......

Страница 5: ...ble stub for connection to communications equipment a Polyolefin Insulated Cable PIC stub for connection to the Central Office CO incoming cable and a power cable The shelf s features include the foll...

Страница 6: ...Eight card Shelf Figure 1 Model 751109 13 INTERIOR VIEW CO SIDE TB1 TB1 STATION SIDE TB2 TB2 MOUNTING SLOTS ISOLATION GAP FRONT VIEW 13 5 DANGER POSITRON INC FiberLine Isolator 30 2 9 71 SIDE VIEW ST...

Страница 7: ...sical Specifications For a listing of the module s physical specifications refer to Table 1 Table 1 Physical Specifications Parameter Specifications Height 13 5 34 29 cm Width 30 2 76 71 cm Depth 9 71...

Страница 8: ...Shelf For a listing of pin outs for the CO and the Station side cables color coding refer to Table 2 Note Within the Eight card Shelf lines using DX signalling or DC loopback to power a T1 or HDSL Fou...

Страница 9: ...TB2 14 White Slate Slate White 6 T6 R6 TIP 6 RING 6 TB1 12 TB2 12 Red Blue TB1 13 TB2 13 Red Blue Blue Red 7 T7 R7 TIP 7 RING 7 TB1 11 TB2 11 Red Orange TB1 12 TB2 12 Red Orange Orange Red 8 T8 R8 TI...

Страница 10: ...V SUPPLY 48V SUPPLY 48V SUPPLY N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A TB1 2 TB1 2 TB1 1 TB1 1 TB2 1 TB2 1 TB2 2 TB2 2 Yellow Green Green Yellow Violet Brown Brown Violet Yello...

Страница 11: ...PR or transients are less likely to occur It is strictly forbidden to install any additional hardware inside the shelf or to drill any holes in its surface Doing so would greatly compromise safety and...

Страница 12: ...coding 10 1 207 751115 406 Eight card Shelf accessory kit 1 241 010101 401 Power Supply cable 1 207 990000 093 Drilling template 1 220 000040 201 Connector cord grip hub 3 4 1 230 990400 025 Connecto...

Страница 13: ...s indicated on the template drill three holes for the 14 screws supplied Remove the template and install the screws 5 Before mounting the shelf on the wall open the cover of the shelf by removing the...

Страница 14: ...e ground wire in order to prevent an electric arc between the two in the event of damage to or degradation of their insulation For an illustration refer to Figure 2 Figure 2 CO and Station Cable Separ...

Страница 15: ...ing and body and slide it up the cable from the free end outside the shelf to the shelf opening Secure the cable by holding the nut inside the shelf and tightening the grip by turning the gland nut Da...

Страница 16: ...CONNECTORS ON STATION CABLE 18 TB1 RU GEN GND TIP 18 1 24V 48V RING TB2 T1 T2 T3 T4 T5 T6 T7 T8 TJ TH TF TE TD TC TB TA R1 R2 R3 R4 R5 R6 R7 R8 RJ RH RF RD RC RB RA RE 1 1 18 18 17 17 16 16 15 15 14...

Страница 17: ...8 3 17 4 16 5 15 6 14 7 13 8 12 9 11 10 1 2 TB2 1 A 2 B 3 C 4 D 5 E 6 F 7 H 8 J RING 3 18 4 17 5 16 6 15 7 14 8 13 9 12 10 11 2 1 TB1 A 1 B 2 C 3 D 4 E 5 F 6 H 7 J 8 G N D R U G E N TIP 24V 24V 48V RU...

Страница 18: ...inside of the shelf pass the free end of the cable through the bottom left hand side 3 Plug the male connectors into female receptacles TB1 and TB2 mounted in the bottom left hand corner of the shelf...

Страница 19: ...interconnections refer to Figure 6 The PIC stub must be spliced to the incoming CO cable using a high dielectric splice case All interconnections should be completely isolated from anything that is o...

Страница 20: ...TALLED VIEW FEMALE RECEPTACLES CO SIDE PCB MARKINGS TB2 TB1 TB2 1 RING 17 RMT GND RA RB RC RD RE R5 R4 R3 R2 R1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 RF RG RH R8 R7 R6 TB1 1 TIP 17 RMT GND TA TB T...

Страница 21: ...10 1 J1 J2 J3 J4 J5 J6 J7 J8 A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F A 3 C 5 E 6 F 17 2 16 3 15 4 5 14 13 6 12 7 11 8 10 9 1 TB2 TB1 E1 E2 E4...

Страница 22: ...ntrance hole must be selected To connect the CO side cable without using the PIC stub 1 Remove the male connectors from the PIC stub supplied using a 1 8 common blade screw driver These connectors wil...

Страница 23: ...Secure the cable by holding the nut inside the shelf and tightening the grip by turning the gland nut Danger The sheath of the CO cable must not be connected to station ground The wires themselves sho...

Страница 24: ...he shelf using an external power supply there are two methods as listed below To power the shelf via the station cable The shelf may be powered via the station cable by an external 24 V dc or 48 V dc...

Страница 25: ...ling the charging of the battery pack model 751312 Then connect the power cable provided to TB3 the Power Supply Card itself can only be powered via TB3 refer to Section 6 2 on page 1 24 Station Cable...

Страница 26: ...e connections For a list of the connector positions when using a power cable refer to Table 5 Table 5 Shelf Powering Via Power Cable Models 751109 13 Description Connector Position Ground TB1 2 Ring u...

Страница 27: ...ternal Power Supply EXTERNAL POWER SUPPLY VIA STATION CABLE EXTERNAL POWER SUPPLY VIA POWER CABLE OR 18 TB1 GND TIP 1 1 18 18 17 17 16 16 15 15 14 14 13 13 12 12 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3...

Страница 28: ...ible power supply UPS option is also available It consists of the Power Supply Card model 751313 in conjunction with the Battery Backup Card model 751312 If the Battery Backup Card is not necessary th...

Страница 29: ...e If you are using the power supply card model 751324 you must use a 5A fuse included in the 751324 kit part 241 010297 401 Description Connector Position Wire Color Live TB3 1 Black Ground TB3 2 Gree...

Страница 30: ...by turning the gland nut Attention Female receptacle TB3 is intended exclusively for the internal power supply option STATION SIDE DANGER DO NOT ALLOW CABLE TO SAG INTO THE ISOLATION GAP 18 17 16 15...

Страница 31: ...connection refer to Figure 9 Figure 9 Ground Connections Side View The LED indicates the presence of 24 V dc in the shelf regardless if it is from an external or an internal power supply The 2 amp re...

Страница 32: ...d must be in its connected position if the station ground lug is not used Otherwise the ground strap must be in the disconnected position For an illustration of the ground strap settings refer to Figu...

Страница 33: ...llows the procedure For a list of the thermal specifications for all Teleline cards designed for use with the Eight card Shelf refer to Table 8 Table 8 Thermal Specifications Model No Power Consumptio...

Страница 34: ...4 V 20 to 65 C 400 mA at 24V 5 6 W at 48 V 20 to 65 C 751321B 200 mA at 24 V 1 W 24 V 20 to 65 C 200 mA at 24V 2 8 W 48 V 20 to 65 C 751321C 400 mA at 24V 2 W at 24 V 20 to 65 C 400 mA at 24V 5 6 W at...

Страница 35: ...value represents the Total Power Dissipation 4 The Maximum Operating Temperature of a card represents the highest temperature at which a card can remain operational At the bottom of the maximum operat...

Страница 36: ...llowable Temperature If the calculated temperature is higher than the highest allowable temperature the following can be done Reduce the number of cards in the shelf by distributing the cards among ot...

Страница 37: ...5 7501 15B 6W 5 5W 50 C 6 7501 16B 8 4W 8 5W 50 C 7 751321 4 8W 1W 24v 65 C 8 751321 4 8W 1W 24v 65 C Internal Power Supply 751313 N A 25 of Total power consumption 6W 65 C Total power consumption 24W...

Страница 38: ...mage to the cover Once the temperature of the shelf has been calculated the desired cards can be inserted and the cover replaced with the supplied nuts For information relevant to any card refer to th...

Страница 39: ...nformation regarding field assistance may be obtained by contacting the Technical Customer Support department Please contact Positron for scheduling at least four weeks prior to the actual requested v...

Страница 40: ...is into consideration when requesting a Return Material Authorization RMA number Before returning any items to Positron for repair warranty repair or replacement call the Repair department to obtain a...

Страница 41: ...e All orders must be followed by a confirming order Equipment will not be shipped until such confirmation is received For a list of our contact information refer to Table 11 Table 11 Positron Contact...

Страница 42: ...lation Worksheet The temperature inside the shelf must be lower than the Highest Allowable Temperature including the internal power supply if used Shelf Thermal Resistance 0 31 C W Slot No Model Power...