Eight-card Shelf
21
751109/13
Table 4
Shelf Powering Via Station Side Cable: Model
751109/13
Caution
•
If an external DC supply is not available, a Power Supply Card (model
751313) will be needed. To connect the power cable, refer to Section 6.2
on page 1-24.
•
If an external DC supply is available, and you have decided to add an
internal power supply, you must first disconnect the -24 V dc input to
TB2. You need to do this because this input is on the same bus as the
power supply output and it will load the power supply down since the
internal power supplies are adjusted to -27 V dc (enabling the charging
of the battery pack, model 751312). Then connect the power cable
provided to TB3 (the Power Supply Card itself can only be powered via
TB3), refer to Section 6.2 on page 1-24.
Station Cable with Color Coding 751109/13
Label
Description
Connector
Position
25-Pair Cable
GND
Ground
TB1-2
Yellow/Green
GND
Ground
TB1-2
Green/Yellow
RU GEN
Ring-up Gen
TB1-1
Violet/Brown
RU GEN
Ring-up Gen
TB1-1
Brown/Violet
-24V
-24V Supply
TB2-1
Yellow/Slate
-24V
-24V Supply
TB2-1
Slate/Yellow
-48V
-48V Supply
TB2-2
Violet/Orange
-48V
-48V Supply
TB2-2
Orange/Violet
Note: For floating 130 V dc, connect the positive lead (0V) to TB1-1 (RU GEN) and the negative
lead (130 V dc) to TB2-2 (-48V). For floating 48 V dc, connect the positive lead (0V) to TB1-1
(RU GEN) and the negative lead (-48 V dc) to TB2-2 (-48V).