Electrical Installation
3.3
Electrical Installation
1. Route the station battery cables to the power supply input terminal block. The
table below lists the power supply input connections.
Table 5: Standalone Power Supply Input Connections
Station
Power Supply Input
129 Vdc battery, negative lead
-
129 Vdc battery, positive lead
+
Station ground
Support GND connection using the two-hole
lug provided
2. For a 3-card Shelf, the only entry is through the Station side cable.
Table 6: Standalone power Supply Unit Output Connections to a 3-card
Shelf via the Station Side Cable
External Supply
Connector Position
(3-Card Shelf)
Wire Color
-24 Vdc
Ground
TB2-9
TB2-9
Red/Orange
Orange/Red
-24 Vdc
TB2-11
TB2-11
Brown/Red
Red/Brown
3. For a 5- or 8-card Shelf: either connect the power supply output to the shelf
using the Station side cable, or use a power cord connected to TB1-2
(Ground) and TB2-1 (-24 Vdc).
C
AUTION
The Station and Central Office (CO) cables should be kept at least six inches
apart upon wiring in order to prevent an electric arc between the two in the
event of damage to, or degradation of, their insulation.