Cable Color Code Identification
This splicing sequence will then join sheath cable pairs 1 through 5 to slots 1
through 5 for a two wire circuit. It will also join sheath cable pairs 9 through 13 to
slots 1 through 5 for the second half of a four wire circuit(s). This then results in
the following cable pair assignment for a series of four wire circuits:
Table 8: Cable Pair Assignments
CO Side Cable Pair list
Equates to Shelf Slot Position List
1 & 9
1
2 & 10
2
3 & 11
3
4 & 12
4
5 & 13
5
The shelf stub cable pairs are terminated onto the isolation jacks. The tip of the
jack is the 'Tip' conductor and the shorter or higher pin on the jack is the 'Ring'
conductor location. The jacks are numbered from top to bottom, with the top jack
being number 1. The jack may utilize a screw terminal or wire wrap connection
method. This will insure that the circuits will appear in the shelf as expected,
designed, and listed in the Circuit Assignment List.
Q
Do not BOND or GROUND the cable shield.
The attachment sequence for the 751112 cable stub to the Isolation jack is shown
in Table 9 on page 40.
C
AUTION
Содержание Teleline 751960/13CU5
Страница 2: ......
Страница 6: ......
Страница 7: ...Chapter 1 General Information...
Страница 14: ......
Страница 15: ...Chapter 2 Overview...
Страница 17: ...17 Introduction Figure 1 HVI Pre configured Unit 751960 13CU5...
Страница 20: ......
Страница 21: ...Chapter 3 Installation...
Страница 51: ...Chapter 4 Thermal Considerations...
Страница 57: ...Appendix A Acronyms...